Of the many factors determining host biocompatibility responses to implanted biomedical polymers, the cellular interactions at the tissue/material interface have been recognized to be some of the most important. The present study has combined results both from an in vitro cell culture system and from an in vivo animal model to examine this host response. In vitro results suggest that a variety of polymer materials can differentially activate human monocytes to produce a protein(s) having different biological activites. The polymers tested induce the production of the regulatory inflammatory protein interleukin 1 as well as a factor that enhances fibroblast proliferation and collagen synthesis. The observed activities of these factors appear to be related but not identical, and are dependent upon the specific polymer. Evaluation of exudate and tissue responses to these same polymer materials in an in vivo model are also presented. Both in vitro and in vivo results support the hypothesis that monocyte/macrophage activation with subsequent synthesis of regulatory factors such as interleukin 1 plays a significant role in determining the host response to biomedical polymer implants.

Overview

Integrity signals

Registry

Crossref · 10.1002/jbm.820230904

Cites

24 of 24 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 24 references

Research works printed but not linked: 1

  1. 10.1016/S0022-1759(80)80012-3 · doi:10.1016/s0022-1759(80)80012-3 · Paper page

Cited by

See all 84

Metadata

Authors
Miller, K. M., Rose‐Caprara, V., & Anderson, J. M.
Affiliations
Case Western Reserve University (US)
Corresponding author
Anderson, James M.
Venue
Journal of Biomedical Materials Research
Publisher
Wiley
Published
1989-09
Volume
23
Issue
9
Pages
1007-1026
ISSN
  • 0021-9304 (ISSN-L)
  • 1097-4636
OpenAlex
W2039156036
Cited by
84
References
24
Citations by year
2023: 1 · 2021: 1 · 2020: 1 · 2017: 1 · 2015: 2 · 2013: 3 · 2012: 2
FWCI
5.00
Type
journal article
Language
en
Open access
closed
Locations
  • Journal of Biomedical Materials Research (publishedVersion)
  • PubMed (publishedVersion)
Funders
National Heart, Lung, and Blood Institute (HL-27277, HL 33849)
Topics
  • Physical Sciences › Materials Science › Surfaces, Coatings and Films › Polymer Surface Interaction Studies
  • Health Sciences › Medicine › Surgery › Orthopaedic implants and arthroplasty
  • Physical Sciences › Engineering › Biomedical Engineering › Bone Tissue Engineering Materials
Keywords
interleukin-1, monocyte activation, macrophage activation, inflammation, fibroblast proliferation, collagen synthesis, in vitro cell culture, in vivo animal models
MeSH terms
Adult, Animals, Biocompatible Materials, Capsules, Cell Division, Exudates and Transudates, Female, Fibroblasts, Humans, Interleukin-1, Macrophage Activation, Mice, Inbred C3H, Models, Biological, Monocytes, Polyethylene Terephthalates, Polymers, Rats, Inbred Strains, T-Lymphocytes, Diffusion Chambers, Culture, Prostheses and Implants, Mice, Rats

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Generation of IL1‐like activity in response to biomedical polymer implants: A comparison of in vitro and in vivo models. https://app.cochat.ai/papers/10.1002/jbm.820230904
The paper
Miller, K. M., Rose‐Caprara, V., & Anderson, J. M. (1989). Generation of IL1‐like activity in response to biomedical polymer implants: A comparison of in vitro and in vivo models. Journal of Biomedical Materials Research. https://doi.org/10.1002/jbm.820230904

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.