The bovine pericardial xenograft: I. Effect of fixation in aldehydes without constraint on the tensile viscoelastic properties of bovine pericardium
The DOI matches its Crossref record.
Abstract
Tensile testing of tissue strips has been used to examine the effect of simple fixation in glutaraldehyde and formaldehyde on the viscoelastic properties of bovine pericardium. To assess tissue anisotropy, tissue strips were cut at 0°, 30°, 60°, and 90° relative to the base‐to‐apex direction. Fresh anterior pericardium was modestly anisotropic, being least extensible in the base‐to‐apex direction; however, fixation removed this anisotropy. Fixation also produced a marked change in the response of the material to initial cyclic loading during preconditioning. Overall extensibility of the fixed material was significantly greater than that for the fresh tissue, consistent with a 10.7% shrinkage in aldehydes calculated from strain at fracture data. Reductions in stress relaxation and creep after fixation were noted as well, consistent with intrafibrillar crosslinking. Cyclic hysteresis and ultimate tensile strength were unaffected. Since the observed changes in the stress–strain response were largely attributable to shrinkage, control of shrinkage by physical means would allow for engineering modification of bovine pericardial mechanics for controlled anisotropy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Acellular vascular tissues: natural biomaterials for tissue repair and tissue engineering
Schmidt, C. E., & Baier, J. M. (2000) · Biomaterials · doi:10.1016/s0142-9612(00)00148-4 · Cited by 762
Glutaraldehyde as a fixative in bioprostheses and drug delivery matrices
Jayakrishnan, A., & Jameela, S. R. (1996) · Biomaterials · doi:10.1016/0142-9612(96)82721-9 · Cited by 498
Courtman, D. W., Pereira, C. A., Kashef, V., McComb, D., Lee, J. M., & Wilson, G. J. (1994) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820280602 · Cited by 321
Self-citationThe polyvinyl alcohol–bacterial cellulose system as a new nanocomposite for biomedical applications
Millon, L. E., & Wan, W. K. (2006) · Journal of Biomedical Materials Research Part B: Applied Biomaterials · doi:10.1002/jbm.b.30535 · Cited by 296
Crosslinking of biological tissues using genipin and/or carbodiimide
Sung, H., Chang, W., Ma, C., & Lee, M. (2003) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.10346 · Cited by 286
Wan, W. K., Campbell, G., Zhang, Z. F., Hui, A. J., & Boughner, D. R. (2002) · Journal of Biomedical Materials Research · doi:10.1002/jbm.10333 · Cited by 218
“49, which is equivalent to the range of distension of the human aorta within the cardiovascular pressure range of 45 mmHg to 163 mmHg.(28)”
BackgroundMethodSelf-citationSuccessive epoxy and carbodiimide cross-linking of dermal sheep collagen
Zeeman, R., Dijkstra, P. J., van Wachem, P. B., van Luyn, M. J. A., Hendriks, M., Cahalan, P. T., & Feijen, J. (1999) · Biomaterials · doi:10.1016/s0142-9612(98)00242-7 · Cited by 193
Sung, H.-W., Chang, Y., Chiu, C.-T., Chen, C.-N., & Liang, H.-C. (1999) · Journal of Biomedical Materials Research · doi:10.1002/(sici)1097-4636(199911)47:2<116::aid-jbm2>3.0.co;2-j · Cited by 184
Anisotropic polyvinyl alcohol hydrogel for cardiovascular applications
Millon, L. E., Mohammadi, H., & Wan, W. K. (2006) · Journal of Biomedical Materials Research Part B: Applied Biomaterials · doi:10.1002/jbm.b.30543 · Cited by 172
“For cardiovascular tissues, the approximate average strain between diastole and systole for porcine aortic root ranges between 20 and 30%, and the strain range has also been reported to be between 17 and 49% strain.(1,9,10) Even though the physiological average strain of aortic tissue is around 30% strain,(9) data wer…”
Transcatheter Heart Valves: A Biomaterials Perspective
Bui, H. T., Khair, N., Yeats, B., Gooden, S., James, S. P., & Dasi, L. P. (2021) · Advanced Healthcare Materials · doi:10.1002/adhm.202100115 · Cited by 36
Estermann, S.-J., Förster-Streffleur, S., Hirtler, L., Streicher, J., Pahr, D. H., & Reisinger, A. (2021) · Annals of Anatomy - Anatomischer Anzeiger · doi:10.1016/j.aanat.2021.151717 · Cited by 27
Metadata
- Authors
- Lee, J. M., Haberer, S. A., & Boughner, D. R.
- Venue
- Journal of Biomedical Materials Research
- Publisher
- Wiley
- Published
- 1989-05
- Volume
- 23
- Issue
- 5
- Pages
- 457-475
- ISSN
- 0021-9304 (ISSN-L)
- 1097-4636
- OpenAlex
- W2030752852
- Cited by
- 101
- References
- 0
- FWCI
- 2.50
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.