In vitro and ex vivo platelet interactions with hydrophilic‐hydrophobic poly(ethylene oxide)‐polystyrene multiblock copolymers
The DOI matches its Crossref record.
Abstract
Hydrophilic‐hydrophobic multiblock copolymers synthesized from telechelic oligomers of poly(ethylene oxide) (PEO) and polystyrene (PS) have been used to study the influence of hydrophilic and hydrophobic balance on interfacial interactions of these surfaces with blood components. In vitro coagulation assays show no inherent ability of these amphiphilic surfaces to affect contact activation or coagulation factors. In vitro platelet adhesion and release reactions from rabbit platelet‐rich plasma were shown to be greatest on Biomer and PS homopolymer surfaces and least on cross‐linked PEO surfaces, with the PEO–PS block copolymers demonstrating intermediate responses. These same substrates were tested in a new low‐flow, low‐shear arterio–artery shunt system in rabbits. Whole blood occlusion times were not a direct function of hydrophilic content as both PEO and PS homopolymers and Biomer showed short occlusion times, while PEO–PS block copolymers prolonged occlusion times considerably, depending on composition. Overall, results suggest that PEO–PS block copolymers promote unique whole blood responses in contrast to homopolymer and Biomer controls which are more complex than direct correlations to bulk hydrophilic and hydrophobic contents.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Blood compatibility of polyethylene oxide surfaces
LEE, J., LEE, H., & ANDRADE, J. (1995) · Progress in Polymer Science · doi:10.1016/0079-6700(95)00011-4 · Cited by 703
Desai, N. P., & Hubbell, J. A. (1991) · Biomaterials · doi:10.1016/0142-9612(91)90193-e · Cited by 265
Löpez, G. P., Ratner, B. D., Tidwell, C. D., Haycox, C. L., Rapoza, R. J., & Horbett, T. A. (1992) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820260402 · Cited by 260
Biological responses to polyethylene oxide modified polyethylene terephthalate surfaces
Desai, N. P., & Hubbell, J. A. (1991) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820250704 · Cited by 257
XPS and AFM analysis of antifouling PEG interfaces for microfabricated silicon biosensors
Sharma, S., Johnson, R. W., & Desai, T. A. (2004) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2004.01.034 · Cited by 198
“PEG-coupled silicon substrates can be prepared by physical adsorption (Strasser et al., 1989; Grainger et al., 1989; Owens et al., 1987; Amiji et al., 1991; Amiji and Park, 1992; Gingell et al., 1994), covalent coupling (Tseng and Park, 1992; Tseng et al.”
BackgroundAddressing thrombogenicity in vascular graft construction
Sarkar, S., Sales, K. M., Hamilton, G., & Seifalian, A. M. (2007) · Journal of Biomedical Materials Research Part B: Applied Biomaterials · doi:10.1002/jbm.b.30710 · Cited by 182
Quinn, C. P., Pathak, C. P., Heller, A., & Hubbell, J. A. (1995) · Biomaterials · doi:10.1016/0142-9612(95)98856-9 · Cited by 172
Llanos, G. R., & Sefton, M. V. (1993) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820271105 · Cited by 71
Metadata
- Authors
- Grainger, D. W., Nojiri, C., Okano, T., & Kim, S. W.
- Venue
- Journal of Biomedical Materials Research
- Publisher
- Wiley
- Published
- 1989-09
- Volume
- 23
- Issue
- 9
- Pages
- 979-1005
- ISSN
- 0021-9304 (ISSN-L)
- 1097-4636
- OpenAlex
- W2064607098
- Cited by
- 54
- References
- 0
- FWCI
- 2.43
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.