The histological effects of the implantation of different sizes of polyethylene particles in the rabbit tibia
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
This study examines the histological effects of different sizes of polyethylene particles implanted into the rabbit tibia. Seventeen mature New Zealand white female rabbits were allocated into three groups. Group 1 (5 rabbits) received polyethylene particles averaging approximately 16 μm in diameter, implanted into the right proximal tibia through a drill hole. Group 2 (5 animals) received particles averaging 26 μm, and Group 3 (7 rabbits) received particles averaging 67 μm. The left tibia was drilled but not implanted. Animals were sacrificed after 16 weeks. Histological analysis disclosed decreased hematopoietic activity within the left tibial drill hole. In all groups, the right tibia demonstrated positively birefringent polyethylene particles surrounded by, and within (smaller particles), histiocytes and giant cells in a fibrous tissue stroma. Statistical analysis disclosed more fibrocytes and less marrow cells at the interface of Group 3 (largest particles) compared to Group 1 and 2. Larger polyethylene particles, being less readily phagocytosed, appear to produce more fibrous encapsulation, compared to particles of a smaller size. The histological reaction stimulated by the different sizes of polyethylene particles resembled the membrane surrounding loose joint arthroplasties in humans.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Effect of the size and surface charge of polymer microspheres on their phagocytosis by macrophage
Tabata, Y., & Ikada, Y. (1988) · Biomaterials · doi:10.1016/0142-9612(88)90033-6 · Cited by 538
Cited by
Biological reactions to wear debris in total joint replacement
Ingham, E., & Fisher, J. (2000) · Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine · doi:10.1243/0954411001535219 · Cited by 708
The role of macrophages in osteolysis of total joint replacement
Ingham, E., & Fisher, J. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2004.04.035 · Cited by 667
Jiranek, W. A., Machado, M., Jasty, M., Jevsevar, D., Wolfe, H. J., Goldring, S. R., Goldberg, M. J., & Harris, W. H. (1993) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-199306000-00007 · Cited by 436
Composition and morphology of wear debris in failed uncemented total hip replacement
Shanbhag, A., Jacobs, J., Glant, T., Gilbert, J., Black, J., & Galante, J. (1994) · The Journal of Bone and Joint Surgery. British volume · doi:10.1302/0301-620x.76b1.8300684 · Cited by 387
The Cellular and Molecular Biology of Periprosthetic Osteolysis
Purdue, P. E., Koulouvaris, P., Potter, H. G., Nestor, B. J., & Sculco, T. P. (2007) · Clinical Orthopaedics and Related Research · doi:10.1097/01.blo.0000238813.95035.1b · Cited by 372
Metadata
- Authors
- Goodman, S. B., Fornasier, V. L., Lee, J., & Kei, J.
- Venue
- Journal of Biomedical Materials Research
- Publisher
- Wiley
- Published
- 1990-04
- Volume
- 24
- Issue
- 4
- Pages
- 517-524
- ISSN
- 0021-9304 (ISSN-L)
- 1097-4636
- OpenAlex
- W2040792637
- Cited by
- 105
- References
- 1
- FWCI
- 3.93
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The histological effects of the implantation of different sizes of polyethylene particles in the rabbit tibia. https://app.cochat.ai/papers/10.1002/jbm.820240408
- The paper
- Goodman, S. B., Fornasier, V. L., Lee, J., & Kei, J. (1990). The histological effects of the implantation of different sizes of polyethylene particles in the rabbit tibia. Journal of Biomedical Materials Research. https://doi.org/10.1002/jbm.820240408
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.