CoChat

Apatite formation on the surface of ceravital‐type glass‐ceramic in the body

Ohtsuki, C., Kushitani, H., Kokubo, T., Kotani, S., Yamamuro, T. · 1991 · Journal of Biomedical Materials Research

The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.

Abstract

Previous studies on surface structural changes in vitro as well as in vivo of bioactive A‐W‐type glass‐ceramics and Bioglass‐type glasses showed that the essential condition for glasses and glassceramics to bond to living bone is formation of a bonelike apatite layer on their surfaces in the body. Gross et al., however, had explained the bone‐bonding mechanism of Ceravital‐type apatitecontaining glass‐ceramic without mentioning formation of the surface apatite layer. In the present study, apatite formation on the surface of one of Ceravitaltype glass‐ceramics was investigated in vitro as well as in vivo. An apatitecontaining glass‐ceramic of the composition Na 2 O 5, CaO 33, SiO 2 46, Ca(PO 3)2 16 wt%, which was named KGS by Gross et al., was soaked in an acellular simulated body fluid which had ion concentrations almost equal to those of the human blood plasma. The same kind of glassceramic was implanted into a rabbit tibia. Thin‐film x‐ray diffraction, Fourier transform infrared reflection spectroscopy, and scanning electron microscopic observation of the surfaces of the specimens soaked in the simulated body fluid showed that Ceravital‐type glass‐ceramic also forms a layer of carbonate‐containing hydroxyapatite of small crystallites and/or a defective structure on its surface in the fluid. Electron probe x‐ray microanalysis of the interface between the glassceramic and the surrounding bone showed that a thin layer rich in Ca and P is present at the interface. These findings indicated that Ceravital‐type glassceramics also form the bonelike apatite layer on its surface in the body and bond to living bone through the apatite layer.

Overview

Integrity signals

Registry

Crossref · 10.1002/jbm.820251105

Cites

13 of 13 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Research works printed but not linked: 4

  1. Kokubo T., 1987, Ceramics in Clinical Application, 175
  2. Kokubo T., 1990, Bioceramics, 113
  3. Nakamura T., 1983, Treatise on Biomedical Materials, 109
  4. Hench L. L., 1982, Biocompatibility of Orthopaedic Implants, 129

Cited by

See all 288

Metadata

Authors
Ohtsuki, C., Kushitani, H., Kokubo, T., Kotani, S., & Yamamuro, T.
Affiliations
  • Kyoto University Institute for Chemical Research (JP)
  • Kyoto University (JP)
Corresponding author
Ohtsuki, C.
Venue
Journal of Biomedical Materials Research
Publisher
Wiley
Published
1991-11
Volume
25
Issue
11
Pages
1363-1370
ISSN
  • 0021-9304 (ISSN-L)
  • 1097-4636
OpenAlex
W1979146632
Cited by
259
References
13
Citations by year
2026: 1 · 2025: 1 · 2024: 3 · 2023: 6 · 2022: 10 · 2021: 6 · 2020: 7 · 2019: 8 · 2018: 5 · 2017: 7 · 2016: 14 · 2015: 10 · 2014: 5 · 2013: 17 · 2012: 12
FWCI
5.14
Type
journal article
Language
en
Open access
closed
Locations
  • Journal of Biomedical Materials Research (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Bone Tissue Engineering Materials
  • Physical Sciences › Engineering › Mechanical Engineering › Surface Treatment and Coatings
  • Health Sciences › Dentistry › General Dentistry › Dental materials and restorations
Keywords
apatite formation, hydroxyapatite layer, bioactive glass-ceramics, bone bonding, simulated body fluid, rabbit tibia implantation, calcium phosphate, bone-implant interface, surface structural changes
MeSH terms
Animals, Apatites, Body Fluids, Bone Development, Ceramics, Humans, Microscopy, Electron, Scanning, Rabbits, Spectrophotometry, Infrared, Surface Properties, X-Ray Diffraction, Prostheses and Implants

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.