CoChat

TNF and IL‐1 generation by human monocytes in response to biomaterials

Cardona, Mario A., Simmons, Richard L., Kaplan, Sandra S. · 1992 · Journal of Biomedical Materials Research
Cited by 87

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

Abstract

The biocompatibility of surgically implanted materials may be compromised as a consequence of inflammatory reactions associated with phagocyte activation. Two important mediators of the inflammatory response are Interleukin‐1 (IL‐1) and tumor necrosis factor (TNF), both of which exert a wide range of biologic effects on many cells. This study was designed to evaluate the release of these cytokines by human monocytes (HM) brought into contact with four biomaterials utilized in clinical practice: polyurethane, expanded polytetrafluorethylene (ePTFE), Dacron velour, and woven Dacron. In vifro cultures for the generation of IL‐1 and TNF by HM in the presence of the above biomaterials were established by exposing cells to each bio material in the presence and absence of lipopolysaccharide (LPS) with harvest of supernatants after 6 or 18 h. These studies showed that in the absence of LPS, IL‐1 was released only by Dacron velour and woven Dacron associated monocytes while TNF was secreted in response to all of the materials. When LPS was present, however, monocytes associated with all of the materials released IL‐1; and TNF release was greatly augmented. Further, the quantity of released cytokine was directly related to the duration of the association time. This study demonstrated that HM in association with various biomaterials were ctivated to produce both TNF and IL‐1 and that the addition of nanogram quantities of LPS, such as would be produced if infection were present, greatly increased the amount of cytokines released.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/jbm.820260703

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 5 references

Cited by

See all 87

Metadata

Authors
Cardona, M. A., Simmons, R. L., & Kaplan, S. S.
Venue
Journal of Biomedical Materials Research
Publisher
Wiley
Published
1992-07
Volume
26
Issue
7
Pages
851-859
ISSN
  • 0021-9304 (ISSN-L)
  • 1097-4636
OpenAlex
W2015759814
Cited by
87
References
5
FWCI
2.30
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: TNF and IL‐1 generation by human monocytes in response to biomaterials. https://app.cochat.ai/papers/10.1002/jbm.820260703
The paper
Cardona, M. A., Simmons, R. L., & Kaplan, S. S. (1992). TNF and IL‐1 generation by human monocytes in response to biomaterials. Journal of Biomedical Materials Research. https://doi.org/10.1002/jbm.820260703

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.