The effects of ultrasound irradiation on a biodegradable 50–50% copolymer of polylactic and polyglycolic acids
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
The aim of this study was to investigate the effects of ultrasound irradiation on a biodegradable drug delivery system. Microporous, disk‐shaped specimens of a 50‐50% copolymer of polylactic and polyglycolic acids were gel cast from an acetone solution. A protein was incorporated in these specimens, which were then immersed in phosphate buffered saline and subjected to ultrasound irradiation every second day. The investigation was performed in two phases: in the first, a study was performed for 58 days to determine if ultrasonic irradiation affected the kinetics of protein release from the specimens. In the second phase, effects of frequency and duration of the ultrasound signal on the degradation of the implant were studied for 40 days. The results indicate that ultrasound irradiation resulted in almost a threefold increase in protein elution from the specimens. Both the ultrasound frequency and signal duration affected the molecular weight loss and mass loss, and changed the overall degradation kinetics of the polymer. © 1994 John Wiley & Sons, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Langer, R. (1990) · Science · doi:10.1126/science.2218494 · Cited by 1,778
Li, S. M., Garreau, H., & Vert, M. (1990) · Journal of Materials Science: Materials in Medicine · doi:10.1007/bf00700871 · Cited by 733
Miller, R. A., Brady, J. M., & Cutright, D. E. (1977) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820110507 · Cited by 722
In vivo and in vitro degradation of glycine/DL‐lactic acid copolymers
Schakenraad, J. M., Nieuwenhuis, P., Molenaar, I., Helder, J., Dijkstra, P. J., & Feijen, J. (1989) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820231105 · Cited by 101
Cited by
Biodegradable polymeric scaffolds for musculoskeletal tissue engineering
Agrawal, C. M., & Ray, R. B. (2001) · Journal of Biomedical Materials Research · doi:10.1002/1097-4636(200105)55:2<141::aid-jbm1000>3.0.co;2-j · Cited by 1,052
Self-citationIn vitro and in vivo degradation of porous poly(dl-lactic-co-glycolic acid) foams
Lu, L., Peter, S. J., D. Lyman, M., Lai, H.-L., Leite, S. M., Tamada, J. A., Uyama, S., Vacanti, J. P., Langer, R., & Mikos, A. G. (2000) · Biomaterials · doi:10.1016/s0142-9612(00)00047-8 · Cited by 668
Degradation of poly-L-lactide. Part 2: increased temperature accelerated degradation
Weir, N. A., Buchanan, F. J., Orr, J. F., Farrar, D. F., & Dickson, G. R. (2004) · Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine · doi:10.1243/0954411041932809 · Cited by 171
Elevated temperature degradation of a 50:50 copolymer of PLA-PGA
Agrawal, C. M., Huang, D., Schmitz, J. P., & Athanasiou, K. A. (1997) · Tissue Engineering · doi:10.1089/ten.1997.3.345 · Cited by 120
“"(3) These polymers are popular for several reasons: they have been used extensively for fabricating implantable devices and have been found to be fairly biocompatible;(4) their structure-property relationships have been examined in detail and have proven to be adequate for numerous implant applications;(5)"(7) additi…”
Self-citationAthanasiou, K. A., Schmitz, J. P., & Agrawal, C. M. (1998) · Tissue Engineering · doi:10.1089/ten.1998.4.53 · Cited by 110
Self-citation
Metadata
- Authors
- Agrawal, C. M., Kennedy, M. E., & Micallef, D. M.
- Venue
- Journal of Biomedical Materials Research
- Publisher
- Wiley
- Published
- 1994-08
- Volume
- 28
- Issue
- 8
- Pages
- 851-859
- ISSN
- 0021-9304 (ISSN-L)
- 1097-4636
- OpenAlex
- W2160426383
- Cited by
- 55
- References
- 4
- FWCI
- 3.13
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.