Biological performance of a degradable poly(lactic acid‐ε‐caprolactone) nerve guide: Influence of tube dimensions
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
One of the ways to reconstruct a nerve defect is to use a biodegradable nerve guide. The aim of this study was to establish a nerve guide constructed of an amorphous copolymer of lactic acid‐caprolactone. A pilot study was set up to elucidate the effect of the tube dimensions on nerve regeneration. Four types of nerve guides, with internal diameters ranging from 1.12–1.23 mm and wall thicknesses ranging from 0.34–0.68, were tested for this purpose. We evaluated the biodegradation, foreign body reaction and nerve regeneration by light microscopy, after three different implantation times (1, 2, and 3 months). After 2 months, we observed that all types of nerve guides had changed from a transparent to an opaque and swollen state, and that they had lost their strength. The foreign body reaction was characterized by the presence of giant cells and fibroblasts surrounding the degrading nerve guide. From this pilot study, we conclude that nerve guide type 1, with an internal diameter of 1.23 mm and a wall thickness of 0.34 mm, can ensure nerve regeneration in the case of a 1‐cm gap in the sciatic nerve of the rat. Nerve guides types 3 and 4, with relatively small lumens, show nerve compression due to a more pronounced swelling of the degrading tube. © 1995 John Wiley & Sons, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Pitt, G. G., Gratzl, M. M., Kimmel, G. L., Surles, J., & Sohindler, A. (1981) · Biomaterials · doi:10.1016/0142-9612(81)90060-0 · Cited by 857
Tissue response to implanted polymers: The significance of sample shape
Matlaga, B. F., Yasenchak, L. P., & Salthouse, T. N. (1976) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820100308 · Cited by 295
Cited by
Keun Kwon, I., Kidoaki, S., & Matsuda, T. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2004.10.007 · Cited by 607
Synthesis, properties and biomedical applications of poly(glycerol sebacate) (PGS): A review
Rai, R., Tallawi, M., Grigore, A., & Boccaccini, A. R. (2012) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2012.02.001 · Cited by 477
Biocompatibility analysis of poly(glycerol sebacate) as a nerve guide material
Sundback, C. A., Shyu, J. Y., Wang, Y., Faquin, W. C., Langer, R. S., Vacanti, J. P., & Hadlock, T. A. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2005.02.004 · Cited by 443
“In comparison, some resorbable materials, notably the lactide-glycolide and lactidecaprolactone copolymers, experience swelling on the order of 100–300%; the resulting distortion narrows the tubular lumen and can impede regeneration [18,19].”
Controlled release of nerve growth factor enhances sciatic nerve regeneration
Lee, A. C., Yu, V. M., Lowe, J. B., Brenner, M. J., Hunter, D. A., Mackinnon, S. E., & Sakiyama-Elbert, S. E. (2003) · Experimental Neurology · doi:10.1016/s0014-4886(03)00258-9 · Cited by 369
Biocompatibility of implantable synthetic polymeric drug carriers: focus on brain biocompatibility
Fournier, E., Passirani, C., Montero-Menei, C. N., & Benoit, J. P. (2003) · Biomaterials · doi:10.1016/s0142-9612(03)00161-3 · Cited by 353
Metadata
- Authors
- Den Dunnen, W. F. A., Van Der Lei, B., Robinson, P. H., Holwerda, A., Pennings, A. J., & Schakenraad, J. M.
- Venue
- Journal of Biomedical Materials Research
- Publisher
- Wiley
- Published
- 1995-06
- Volume
- 29
- Issue
- 6
- Pages
- 757-766
- ISSN
- 0021-9304 (ISSN-L)
- 1097-4636
- OpenAlex
- W1977170360
- Cited by
- 140
- References
- 2
- FWCI
- 1.65
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.