Three‐dimensional culture of differentiating marrow stromal osteoblasts in biomimetic poly(propylene fumarate‐co‐ethylene glycol)‐based macroporous hydrogels
The DOI matches its Crossref record.
Abstract
This study assesses the ability of biomimetic poly(propylene fumarate‐co‐ethylene glycol)‐based hydrogels to sustain the differentiation of marrow stromal cells (MSCs) to the osteoblastic phenotype and to produce a mineralized matrix in vitro. Macroporous hydrogels based on poly(propylene fumarate‐co‐ethylene glycol) with and without covalently linked RGD cell‐adhesive peptide were synthesized and seeded with rat MSCs suspended in media or in a type I collagen solution. Cells suspended in media were found to adhere to RGD‐modified but not to unmodified hydrogels. Cells suspended in a collagen solution were entrapped after collagen gelation and proliferated independent of the peptide modification of the hydrogel. Hydrogel modification with RGD peptide was sufficient to allow for the adhesion and differentiation of MSCs to the osteoblastic phenotype in the presence of osteogenic culture supplements. MSCs seeded with a collagen gel onto RGD‐modified macroporous hydrogels after 28 days of culture showed a significant increase in cell numbers, from 15,200 ± 2,000 to 208,600 ± 69,700 cells (p < 0.05). Moreover, significant calcium deposition was apparent after 28 days of culture in RGD‐modified hydrogels for cells suspended in a collagen gel in comparison to cells suspended in media, 3.47 ± 0.26 compared to 0.82 ± 0.20 mg Ca 2+ per scaffold (p < 0.05). Confocal microscopy revealed that MSCs suspended in a collagen gel and cultured on RGD‐modified hydrogels for 28 days were adhered to the surface of the hydrogel while MSCs suspended in a collagen gel and cultured on unmodified hydrogels were located within the pores of and not in direct contact with the hydrogel surface. The results demonstrate that these biomimetic hydrogels facilitate the adhesion and support the differentiation of MSCs to the osteoblastic phenotype in the presence of osteogenic culture media. © 2003 Wiley Periodicals, Inc. J Biomed Mater Res 66A: 698–706, 2003
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Lutolf, M. P., & Hubbell, J. A. (2005) · Nature Biotechnology · doi:10.1038/nbt1055 · Cited by 4,551
Polymeric Scaffolds in Tissue Engineering Application: A Review
Dhandayuthapani, B., Yoshida, Y., Maekawa, T., & Kumar, D. S. (2011) · International Journal of Polymer Science · doi:10.1155/2011/290602 · Cited by 1,773
“The synthetic polymers are PLA [162], PPFderived Copolymers [163], PEG-derivatives, and PVA [164].”
BackgroundBiomaterials: Where We Have Been and Where We Are Going
Ratner, B. D., & Bryant, S. J. (2004) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.6.040803.140027 · Cited by 1,507
Biocompatible polymer materials: Role of protein–surface interactions
Chen, H., Yuan, L., Song, W., Wu, Z., & Li, D. (2008) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2008.07.006 · Cited by 706
Future Prospects for Scaffolding Methods and Biomaterials in Skin Tissue Engineering: A Review
Chaudhari, A., Vig, K., Baganizi, D., Sahu, R., Dixit, S., Dennis, V., Singh, S., & Pillai, S. (2016) · International Journal of Molecular Sciences · doi:10.3390/ijms17121974 · Cited by 604
Hydrogel scaffolds for tissue engineering: the importance of polymer choice
Spicer, C. D. (2020) · Polymer Chemistry · doi:10.1039/c9py01021a · Cited by 527
Design Strategies of Tissue Engineering Scaffolds with Controlled Fiber Orientation
Murugan, R., & Ramakrishna, S. (2007) · Tissue Engineering · doi:10.1089/ten.2006.0078 · Cited by 415
Matrices and scaffolds for protein delivery in tissue engineering
Tessmar, J. K., & Göpferich, A. M. (2007) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2007.03.020 · Cited by 346
Latest Advances in Cryogel Technology for Biomedical Applications
Memic, A., Colombani, T., Eggermont, L. J., Rezaeeyazdi, M., Steingold, J., Rogers, Z. J., Navare, K. J., Mohammed, H. S., & Bencherif, S. A. (2019) · Advanced Therapeutics · doi:10.1002/adtp.201800114 · Cited by 310
Influence of macroporous protein scaffolds on bone tissue engineering from bone marrow stem cells
Kim, H. J., Kim, U.-J., Vunjak-Novakovic, G., Min, B.-H., & Kaplan, D. L. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2004.11.013 · Cited by 301
Bio-adhesive Surfaces to Promote Osteoblast Differentiation and Bone Formation
García, A. J., & Reyes, C. D. (2005) · Journal of Dental Research · doi:10.1177/154405910508400502 · Cited by 281
Mauney, J. R., Volloch, V., & Kaplan, D. L. (2005) · Tissue Engineering · doi:10.1089/ten.2005.11.787 · Cited by 269
Various manufacturing methods and ideal properties of scaffolds for tissue engineering applications
Suamte, L., Tirkey, A., Barman, J., & Jayasekhar Babu, P. (2023) · Smart Materials in Manufacturing · doi:10.1016/j.smmf.2022.100011 · Cited by 259
Hennessy, K. M., Pollot, B. E., Clem, W. C., Phipps, M. C., Sawyer, A. A., Culpepper, B. K., & Bellis, S. L. (2009) · Biomaterials · doi:10.1016/j.biomaterials.2008.12.053 · Cited by 167
Cai, Z., Wan, Y., Becker, M. L., Long, Y.-Z., & Dean, D. (2019) · Biomaterials · doi:10.1016/j.biomaterials.2019.03.038 · Cited by 133
Metadata
- Authors
- Behravesh, E., & Mikos, A. G.
- Venue
- Journal of Biomedical Materials Research Part A
- Publisher
- Wiley
- Published
- 2003-08-06
- Volume
- 66A
- Issue
- 3
- Pages
- 698-706
- ISSN
- 1549-3296 (ISSN-L)
- 1552-4965
- OpenAlex
- W1995608027
- Cited by
- 86
- References
- 0
- FWCI
- 5.12
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.