Hydrogels based on poly(ethylene oxide) and poly(tetramethylene oxide) or poly(dimethyl siloxane). III. In vivo biocompatibility and biostability
The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
To investigate the effects of polymer chemistry and topology (linear or graft copolymer) on in vivo biocompatibility and biostability based on cage implant system, various hydrogels, composed of short hydrophilic [polyethylene oxide (PEO)] and hydrophobic block, were prepared by polycondensation reaction. Poly(tetramethylene oxide) (PTMO) or poly(dimethyl siloxane) (PDMS) was chosen as a hydrophobic block because of their wide utilization as a biomaterial. By using the specimens retrieved from rats killed after 1, 2, 3, 5, and 7 weeks' implantation, cellular and material responses were assessed. Most hydrogels showed a comparable value of macrophage density to Pellethane®, control polymer, whereas they did significantly lower foreign body giant cell (FBGC) density and coverage because of the presence of PEO. However, PEO block length and polymer topology did not affect macrophage adhesion and FBGC formation in our polymer composition. The hydrogel based on PDMS alone showed significantly lower macrophage density and FBGC density than Pellethane®, indicating that PDMS plays a role in inhibiting cellular adhesion. The results obtained from gel permeation chromatography curve and Fourier transform infrared spectra exhibited that all the polymers were susceptible to oxidative degradation in vivo. Although Pellethane® revealed surface degradation by 5 weeks in vivo, hydrogels showed rapid degradation in the bulk within 2 weeks because of the penetration of oxidative chemicals released from phagocytic cells into PEO domain of phase‐separated hydrogels. The more significant degradation was observed in the hydrogels with longer PEO block and PTMO as a hydrophobic block instead of PDMS. It was evident that the minor degradation could be achieved by grafting PEO and adopting PDMS as a hydrophobic block in the hydrogel. © 2002 Wiley Periodicals, Inc. J Biomed Mater Res 64A: 309–319, 2003
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Biomaterial biocompatibility and the macrophage
Anderson, J. M., & Miller, K. M. (1984) · Biomaterials · doi:10.1016/0142-9612(84)90060-7 · Cited by 403
Zhao, Q., Topham, N., Anderson, J. M., Hiltner, A., Lodoen, G., & Payet, C. R. (1991) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820250205 · Cited by 318
In vivo biocompatibility studies. I. The cage implant system and a biodegradable hydrogel
Marchant, R., Hiltner, A., Hamlin, C., Rabinovitch, A., Slobodkin, R., & Anderson, J. M. (1983) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820170209 · Cited by 181
Zhao, Q. H., McNally, A. K., Rubin, K. R., Renier, M., Wu, Y., Rose‐Caprara, V., Anderson, J. M., Hiltner, A., Urbanski, P., & Stokes, K. (1993) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820270311 · Cited by 140
Kao, W. J., Zhao, Q. H., Hiltner, A., & Anderson, J. M. (1994) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820280110 · Cited by 85
Cited by
Biomedical applications of biodegradable polymers
Ulery, B. D., Nair, L. S., & Laurencin, C. T. (2011) · Journal of Polymer Science Part B: Polymer Physics · doi:10.1002/polb.22259 · Cited by 2,206
Engineering biomaterials to integrate and heal: The biocompatibility paradigm shifts
Bryers, J. D., Giachelli, C. M., & Ratner, B. D. (2012) · Biotechnology and Bioengineering · doi:10.1002/bit.24559 · Cited by 271
“…reduced protein adsorption and leukocyte adhesion in vitro, inconsistent results have been obtained regarding the ability of these polymeric coatings to reduce in vivo acute and chronic inflammatory responses (Park and Bae, 2003; Quinn et al., 1995; Ronneberger et al., 1996; Shen et al., 2002).”
BackgroundConcurrent delivery of dexamethasone and VEGF for localized inflammation control and angiogenesis
Patil, S. D., Papadmitrakopoulos, F., & Burgess, D. J. (2007) · Journal of Controlled Release · doi:10.1016/j.jconrel.2006.10.013 · Cited by 230
Design of Multiresponsive Hydrogel Particles and Assemblies
Hendrickson, G. R., Smith, M. H., South, A. B., & Lyon, L. A. (2010) · Advanced Functional Materials · doi:10.1002/adfm.200902429 · Cited by 182
Anti-Inflammatory Polymeric Coatings for Implantable Biomaterials and Devices
Bridges, A. W., & García, A. J. (2008) · Journal of Diabetes Science and Technology · doi:10.1177/193229680800200628 · Cited by 181
In vivo cytokine-associated responses to biomaterials
Schutte, R. J., Xie, L., Klitzman, B., & Reichert, W. M. (2009) · Biomaterials · doi:10.1016/j.biomaterials.2008.09.026 · Cited by 111
“Other cage implant studies have shown that specimen surface chemistry impacts macrophage adhesion, FBGC fusion, apoptosis, microvessel growth, and surface protein expression in vivo [12–16].”
Background
Metadata
- Authors
- Hyung Park, J., & Bae, Y. H.
- Venue
- Journal of Biomedical Materials Research Part A
- Publisher
- Wiley
- Published
- 2002-12-20
- Volume
- 64A
- Issue
- 2
- Pages
- 309-319
- ISSN
- 1549-3296 (ISSN-L)
- 1552-4965
- OpenAlex
- W2084724257
- Cited by
- 35
- References
- 5
- FWCI
- 0.46
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.