Relative influence of polymer fiber diameter and surface charge on fibrous capsule thickness and vessel density for single‐fiber implants

Sanders, J. E., Cassisi, D. V., Neumann, T., Golledge, S. L., Zachariah, S. G., Ratner, B. D., Bale, S. D.·2003·Journal of Biomedical Materials Research Part A

Abstract

Single polypropylene microfibers plasma‐coated with polymers of different surface charge [N,N‐dimethylaminoethyl methacrylate (NN) (positive charge), methacrylic acid (MA) (negative charge), and hexafluoropropylene (HF) (neutral)] were implanted in the subcutaneous dorsum of Sprague‐Dawley rats for 5‐week intervals. Thee groups of fiber diameters were used: (I) 1.0 to 5.9 μm; (II) 6.0 to 10.9 μm; and (III) 11.0 to 15.9 μm. Fibrous capsule thickness and blood‐vessel density (number of vessels within 100 μm of the fiber) were assessed in tissue sections in the planes of microfiber cross‐sections. Results from a multifactorial analysis of variance demonstrated statistically significant main effects (p < 0.05) for microfiber diameter but not for surface‐charge coating. The mean differences in capsule thickness among the microfiber diameter groups were: between groups II and I: 5.4 μm; between groups III and I: 10.2 μm; and between groups III and II: 4.7 μm. The mean differences in capsule thickness among surface‐charge coatings were: between MA and NN: 0.7 μm; between MA and HF: 1.4 μm; and between NN and HF: 0.7 μm. Many of the 1.0 to 5.9 μm‐in‐diameter fibers had no capsule and no sign of a foreign‐body reaction. For the vessel density analysis, neither microfiber diameter nor surface‐charge coating had a statistically significant effect. Thus the geometric feature of microfiber diameter was more important than was surface charge relative to fibrous capsule formation but not relative to local vessel density. This ranking of the relative influence of design features in relation to tissue response provides useful information for prioritization in biomaterial design. © 2003 Wiley Periodicals, Inc. J Biomed Mater Res 65A: 462–467, 2003

Integrity signals

Registry

Crossref · 10.1002/jbm.a.10525

Cites

7 of 7 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Small electrospun fibers (<6 μm in diameter) reduce the foreign body response more effectively than larger fibers (>6 μm).

    “small fibers (<6 μm in diameter)151,163 reduce the FBR (i.e., capsule formation) more effectively than larger (>6 μm) fibers.”
  • Lower modulus fibers such as polyurethane showed reduced capsule formation compared to higher modulus materials such as polyethylene, polyester, and poly(L-lactic acid).

    “lower modulus fibers (e.g., polyurethane) showing reduced capsule formation (i.e., size) compared to higher modulus materials (e.g., polyethylene, polyester and poly(L-lactic acid)).151”

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Sanders, J. E., Cassisi, D. V., Neumann, T., Golledge, S. L., Zachariah, S. G., Ratner, B. D., & Bale, S. D.
Affiliations
University of Washington (US)
Corresponding author
Sanders, J. E.
Venue
Journal of Biomedical Materials Research Part A
Publisher
Wiley
Published
2003-05-09
Volume
65A
Issue
4
Pages
462-467
ISSN
  • 1549-3296 (ISSN-L)
  • 1552-4965
OpenAlex
W2013418259
Cited by
35
References
7
Citations by year
2024: 1 · 2023: 2 · 2021: 2 · 2020: 1 · 2019: 2 · 2018: 2 · 2017: 5 · 2016: 1 · 2015: 1 · 2014: 1 · 2013: 1 · 2012: 2
FWCI
0.81
Type
journal article
Language
en
Open access
closed
Locations
  • Journal of Biomedical Materials Research Part A (publishedVersion)
  • PubMed (publishedVersion)
Funders
  • National Center for Research Resources (RR 01296, P41RR001296)
  • Eunice Kennedy Shriver National Institute of Child Health and Human Development (HD-38554, R01HD038554)
Topics
  • Physical Sciences › Materials Science › Biomaterials › Electrospun Nanofibers in Biomedical Applications
  • Health Sciences › Medicine › Surgery › Tissue Engineering and Regenerative Medicine
  • Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
Keywords
polypropylene microfibers, plasma coating, surface charge, fiber diameter, foreign body reaction, blood vessel density, subcutaneous implantation, biomaterial design, N,N-dimethylaminoethyl methacrylate, methacrylic acid, hexafluoropropylene
MeSH terms
Animals, Biocompatible Materials, Electrochemistry, Fluorocarbon Polymers, Materials Testing, Polymers, Polymethacrylic Acids, Polypropylenes, Polytetrafluoroethylene, Surface Properties, Rats, Sprague-Dawley, Prostheses and Implants, Rats

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review