Relative influence of polymer fiber diameter and surface charge on fibrous capsule thickness and vessel density for single‐fiber implants
Abstract
Single polypropylene microfibers plasma‐coated with polymers of different surface charge [N,N‐dimethylaminoethyl methacrylate (NN) (positive charge), methacrylic acid (MA) (negative charge), and hexafluoropropylene (HF) (neutral)] were implanted in the subcutaneous dorsum of Sprague‐Dawley rats for 5‐week intervals. Thee groups of fiber diameters were used: (I) 1.0 to 5.9 μm; (II) 6.0 to 10.9 μm; and (III) 11.0 to 15.9 μm. Fibrous capsule thickness and blood‐vessel density (number of vessels within 100 μm of the fiber) were assessed in tissue sections in the planes of microfiber cross‐sections. Results from a multifactorial analysis of variance demonstrated statistically significant main effects (p < 0.05) for microfiber diameter but not for surface‐charge coating. The mean differences in capsule thickness among the microfiber diameter groups were: between groups II and I: 5.4 μm; between groups III and I: 10.2 μm; and between groups III and II: 4.7 μm. The mean differences in capsule thickness among surface‐charge coatings were: between MA and NN: 0.7 μm; between MA and HF: 1.4 μm; and between NN and HF: 0.7 μm. Many of the 1.0 to 5.9 μm‐in‐diameter fibers had no capsule and no sign of a foreign‐body reaction. For the vessel density analysis, neither microfiber diameter nor surface‐charge coating had a statistically significant effect. Thus the geometric feature of microfiber diameter was more important than was surface charge relative to fibrous capsule formation but not relative to local vessel density. This ranking of the relative influence of design features in relation to tissue response provides useful information for prioritization in biomaterial design. © 2003 Wiley Periodicals, Inc. J Biomed Mater Res 65A: 462–467, 2003
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Small electrospun fibers (<6 μm in diameter) reduce the foreign body response more effectively than larger fibers (>6 μm).
“small fibers (<6 μm in diameter)151,163 reduce the FBR (i.e., capsule formation) more effectively than larger (>6 μm) fibers.”
From Biocompatible Materials for Continuous Glucose Monitoring Devices (2013) · cites this paper as [151]
Lower modulus fibers such as polyurethane showed reduced capsule formation compared to higher modulus materials such as polyethylene, polyester, and poly(L-lactic acid).
“lower modulus fibers (e.g., polyurethane) showing reduced capsule formation (i.e., size) compared to higher modulus materials (e.g., polyethylene, polyester and poly(L-lactic acid)).151”
From Biocompatible Materials for Continuous Glucose Monitoring Devices (2013) · cites this paper as [151]
Cites
van Wachem, P. B., Hogt, A. H., Beugeling, T., et al. (1987) · Biomaterials · doi:10.1016/0142-9612(87)90001-9 · Cited by 376 · see citing works
The influence of micro-topography on cellular response and the implications for silicone implants
von Recum, A. F., & van Kooten, T. G. (1996) · Journal of Biomaterials Science Polymer Edition · doi:10.1163/156856295x00698 · Cited by 251 · see citing works
Fibroblast cell proliferation on charged hydroxyethyl methacrylate copolymers
Hattori, S., Andrade, J. D., Hibbs, J. B., et al. (1985) · Journal of Colloid and Interface Science · doi:10.1016/0021-9797(85)90010-4 · Cited by 103 · see citing works
Plasma deposition for biomedical applications: A brief review
Ratner, B. D. (1993) · Journal of Biomaterials Science Polymer Edition · doi:10.1163/156856292x00240 · Cited by 85 · see citing works
Self-citationSanders, J. E., Bale, S. D., & Neumann, T. (2002) · Journal of Biomedical Materials Research · doi:10.1002/jbm.10285 · Cited by 82 · see citing works
Self-citationProduction of monoclonal antibodies to study corrosion products of CO-CR biomaterials
Yang, J. M., & Merritt, K. (1996) · Journal of Biomedical Materials Research · doi:10.1002/(sici)1097-4636(199605)31:1 · Cited by 46 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
Biomaterials: Where We Have Been and Where We Are Going
Ratner, B. D., & Bryant, S. J. (2004) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.6.040803.140027 · Cited by 1,507 · see citing works
Self-citationBiocompatible Materials for Continuous Glucose Monitoring Devices
Nichols, S. P., Koh, A., Storm, W. L., Shin, J. H., & Schoenfisch, M. H. (2013) · Chemical Reviews · doi:10.1021/cr300387j · Cited by 347 · see citing works
Foreign Body Reaction to Implantable Biosensors: Effects of Tissue Trauma and Implant Size
Wang, Y., Vaddiraju, S., Gu, B., Papadimitrakopoulos, F., & Burgess, D. J. (2015) · Journal of Diabetes Science and Technology · doi:10.1177/1932296815601869 · Cited by 107 · see citing works
Thinking Small: Progress on Microscale Neurostimulation Technology
Pancrazio, J. J., Deku, F., Ghazavi, A., Stiller, A. M., Rihani, R., Frewin, C. L., Varner, V. D., Gardner, T. J., & Cogan, S. F. (2017) · Neuromodulation: Technology at the Neural Interface · doi:10.1111/ner.12716 · Cited by 60 · see citing works
- Authors
- Sanders, J. E., Cassisi, D. V., Neumann, T., Golledge, S. L., Zachariah, S. G., Ratner, B. D., & Bale, S. D.
- Affiliations
- University of Washington (US)
- Corresponding author
- Sanders, J. E.
- Venue
- Journal of Biomedical Materials Research Part A
- Publisher
- Wiley
- Published
- 2003-05-09
- Volume
- 65A
- Issue
- 4
- Pages
- 462-467
- ISSN
- 1549-3296 (ISSN-L)
- 1552-4965
- OpenAlex
- W2013418259
- Cited by
- 35
- References
- 7
- Citations by year
- 2024: 1 · 2023: 2 · 2021: 2 · 2020: 1 · 2019: 2 · 2018: 2 · 2017: 5 · 2016: 1 · 2015: 1 · 2014: 1 · 2013: 1 · 2012: 2
- FWCI
- 0.81
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Journal of Biomedical Materials Research Part A (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Center for Research Resources (RR 01296, P41RR001296)
- Eunice Kennedy Shriver National Institute of Child Health and Human Development (HD-38554, R01HD038554)
- Topics
- Physical Sciences › Materials Science › Biomaterials › Electrospun Nanofibers in Biomedical Applications
- Health Sciences › Medicine › Surgery › Tissue Engineering and Regenerative Medicine
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Keywords
- polypropylene microfibers, plasma coating, surface charge, fiber diameter, foreign body reaction, blood vessel density, subcutaneous implantation, biomaterial design, N,N-dimethylaminoethyl methacrylate, methacrylic acid, hexafluoropropylene
- MeSH terms
- Animals, Biocompatible Materials, Electrochemistry, Fluorocarbon Polymers, Materials Testing, Polymers, Polymethacrylic Acids, Polypropylenes, Polytetrafluoroethylene, Surface Properties, Rats, Sprague-Dawley, Prostheses and Implants, Rats
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review