Thinking Small: Progress on Microscale Neurostimulation Technology
Open accessAbstract
Objectives Neural stimulation is well-accepted as an effective therapy for a wide range of neurological disorders. While the scale of clinical devices is relatively large, translational, and pilot clinical applications are underway for microelectrode-based systems. Microelectrodes have the advantage of stimulating a relatively small tissue volume which may improve selectivity of therapeutic stimuli. Current microelectrode technology is associated with chronic tissue response which limits utility of these devices for neural recording and stimulation. One approach for addressing the tissue response problem may be to reduce physical dimensions of the device. "Thinking small" is a trend for the electronics industry, and for implantable neural interfaces, the result may be a device that can evade the foreign body response.Materials and methods This review paper surveys our current understanding pertaining to the relationship between implant size and tissue response and the state-of-the-art in ultrasmall microelectrodes. A comprehensive literature search was performed using PubMed, Web of Science (Clarivate Analytics), and Google Scholar.Results The literature review shows recent efforts to create microelectrodes that are extremely thin appear to reduce or even eliminate the chronic tissue response. With high charge capacity coatings, ultramicroelectrodes fabricated from emerging polymers, and amorphous silicon carbide appear promising for neurostimulation applications.Conclusion We envision the emergence of robust and manufacturable ultramicroelectrodes that leverage advanced materials where the small cross-sectional geometry enables compliance within tissue. Nevertheless, future testing under in vivo conditions is particularly important for assessing the stability of thin film devices under chronic stimulation.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The work of Shannon, McCreery et al., and Cogan et al. established guidelines for stimulation levels regarded as safe for the stimulated tissues and the materials of the stimulating electrodes.
“The work of Shannon (21), McCreery et al. (47, 48), and Cogan et al. (20, 49) established some guidelines for stimulation levels that are regarded as safe both for the stimulated tissues and the materials of the stimulating electrodes.”
From Visual percepts evoked with an intracortical 96-channel microelectrode array inserted in human occipital cortex (2021) · cites this paper as [49]
The Introduction’s “Electrical interface challenges for small microelectrodes” section (page unavailable) describes limits intended to protect both tissue and electrodes, including the electrode-material-dependent “water window,” and cites work by Cogan and McCreery. But our copy does not discuss Shannon or state that the three named researchers established the safety guidelines together. (LLM, conf=0.78)
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Cites
Deep Brain Stimulation for Treatment-Resistant Depression
Mayberg, H. S., Lozano, A. M., Voon, V., McNeely, H. E., Seminowicz, D., Hamani, C., Schwalb, J. M., & Kennedy, S. H. (2005) · Neuron · doi:10.1016/j.neuron.2005.02.014 · Cited by 4,059 · see citing works
Bardo, M. T., & Hammer, R. P. (1991) · Neuroscience · doi:10.1016/0306-4522(91)90226-e · Cited by 3,229 · see citing works
Neural Stimulation and Recording Electrodes
Cogan, S. F. (2008) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.10.061807.160518 · Cited by 2,243 · see citing works
Self-citationElectrical stimulation of excitable tissue: design of efficacious and safe protocols
Merrill, D. R., Bikson, M., & Jefferys, J. G. R. (2005) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2004.10.020 · Cited by 2,078 · see citing works
Response of brain tissue to chronically implanted neural electrodes
Polikov, V. S., Tresco, P. A., & Reichert, W. M. (2005) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2005.08.015 · Cited by 1,896 · see citing works
Benabid, A. L., Pollak, P., Gao, D., Hoffmann, D., Limousin, P. D., Gay, E., Payen, I., & Benazzouz, A. (1996) · Journal of neurosurgery · doi:10.3171/jns.1996.84.2.0203 · Cited by 1,135 · see citing works
Perlmutter, J. S., & Mink, J. W. (2006) · Annual Review of Neuroscience · doi:10.1146/annurev.neuro.29.051605.112824 · Cited by 1,073 · see citing works
SU-8: a low-cost negative resist for MEMS
Lorenz, H., Despont, M., Fahrni, N., et al. (1997) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/7/3/010 · Cited by 986 · see citing works
Biran, R., Martin, D. C., & Tresco, P. A. (2005) · Experimental Neurology · doi:10.1016/j.expneurol.2005.04.020 · Cited by 893 · see citing works
Brain responses to micro-machined silicon devices
Szarowski, D. H., Andersen, M. D., Retterer, S. T., Spence, A. J., Isaacson, M. S., Craighead, H. G., Turner, J. N., & Shain, W. G. (2003) · Brain Research · doi:10.1016/s0006-8993(03)03023-3 · Cited by 798 · see citing works
Kozai, T. D. Y., Langhals, N. B., Patel, P. R., Deng, X., Zhang, H., Smith, K. L., Lahann, J., Kotov, N. A., & Kipke, D. R. (2012) · Nature Materials · doi:10.1038/nmat3468 · Cited by 721 · see citing works
Intracortical microstimulation of human somatosensory cortex
Flesher, S. N., Collinger, J. L., Foldes, S. T., Weiss, J. M., Downey, J. E., Tyler-Kabara, E. C., Bensmaia, S. J., Schwartz, A. B., Boninger, M. L., & Gaunt, R. A. (2016) · Science Translational Medicine · doi:10.1126/scitranslmed.aaf8083 · Cited by 704 · see citing works
Mechanical properties of gray and white matter brain tissue by indentation
Budday, S., Nay, R., de Rooij, R., Steinmann, P., Wyrobek, T. J., Ovaert, T. C., & Ellen Kuhl, A. (2015) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2015.02.024 · Cited by 698 · see citing works
Chronic recording capability of the Utah Intracortical Electrode Array in cat sensory cortex
Rousche, P. J., & Normann, R. A. (1998) · Journal of Neuroscience Methods · doi:10.1016/s0165-0270(98)00031-4 · Cited by 646 · see citing works
Ultraflexible nanoelectronic probes form reliable, glial scar–free neural integration
Luan, L., Wei, X., Zhao, Z., Siegel, J. J., Potnis, O., Tuppen, C. A., Lin, S. Q., Kazmi, S., Fowler, R. A., Holloway, S., et al. (2017) · Science Advances · doi:10.1126/sciadv.1601966 · Cited by 618 · see citing works
Cerebral Astrocyte Response to Micromachined Silicon Implants
Turner, J. N., Shain, W. G., Szarowski, D. H., Andersen, M., Martins, S., Isaacson, M. S., & Craighead, H. G. (1999) · Experimental Neurology · doi:10.1006/exnr.1998.6983 · Cited by 593 · see citing works
Cui, X. T., & Martin, D. C. (2003) · Sensors and Actuators B Chemical · doi:10.1016/s0925-4005(02)00448-3 · Cited by 581 · see citing works
Deep brain stimulation for refractory obsessive-compulsive disorder
Abelson, J. L., Curtis, G. C., Sagher, O., Albucher, R. C., Harrigan, M., Taylor, S. F., Martis, B., & Giordani, B. (2005) · Biological Psychiatry · doi:10.1016/j.biopsych.2004.11.042 · Cited by 522 · see citing works
Implanted Neural Interfaces: Biochallenges and Engineered Solutions
Grill, W. M., Norman, S. E., & Bellamkonda, R. V. (2009) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-061008-124927 · Cited by 488 · see citing works
Neural probe design for reduced tissue encapsulation in CNS
Seymour, J. P., & Kipke, D. R. (2007) · Biomaterials · doi:10.1016/j.biomaterials.2007.03.024 · Cited by 462 · see citing works
Progress towards biocompatible intracortical microelectrodes for neural interfacing applications
Jorfi, M., Skousen, J. L., Weder, C., & Capadona, J. R. (2015) · Journal of Neural Engineering · doi:10.1088/1741-2560/12/1/011001 · Cited by 384 · see citing works
In vitro electrical properties for iridium oxide versus titanium nitride stimulating electrodes
Weiland, J. D., Anderson, D. J., & Humayun, M. S. (2002) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2002.805487 · Cited by 382 · see citing works
Sources and effects of electrode impedance during deep brain stimulation
Butson, C. R., Maks, C. B., & McIntyre, C. C. (2005) · Clinical Neurophysiology · doi:10.1016/j.clinph.2005.10.007 · Cited by 361 · see citing works
Servello, D., Porta, M., Sassi, M., Brambilla, A., & Robertson, M. M. (2007) · Journal of Neurology Neurosurgery & Psychiatry · doi:10.1136/jnnp.2006.104067 · Cited by 350 · see citing works
Deep Brain Stimulation for Neurologic and Neuropsychiatric Disorders
Wichmann, T., & DeLong, M. R. (2006) · Neuron · doi:10.1016/j.neuron.2006.09.022 · Cited by 331 · see citing works
Bjornsson, C. S., Oh, S., Al‐Kofahi, Y., Lim, Y.-J., Smith, K. L., Turner, J. N., De, S., Roysam, B., Shain, W. G., & Kim, S. J. (2006) · Journal of Neural Engineering · doi:10.1088/1741-2560/3/3/002 · Cited by 330 · see citing works
Deep brain stimulation for essential tremor: a systematic review
Flora, E. D., Perera, C. L., Cameron, A. L., & Maddern, G. J. (2010) · Movement Disorders · doi:10.1002/mds.23195 · Cited by 323 · see citing works
In Vitro and In Vivo Evaluation of PEDOT Microelectrodes for Neural Stimulation and Recording
Venkatraman, S., Hendricks, J., King, Z. A., Sereno, A. J., Richardson-Burns, S., Martin, D., & Carmena, J. M. (2011) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2011.2109399 · Cited by 319 · see citing works
Davis, T. S., Wark, H. A. C., Hutchinson, D. T., Warren, D. J., O’Neill, K., Scheinblum, T., Clark, G. A., Normann, R. A., & Greger, B. (2016) · Journal of Neural Engineering · doi:10.1088/1741-2560/13/3/036001 · Cited by 314 · see citing works
Toward a comparison of microelectrodes for acute and chronic recordings
Ward, M. P., Rajdev, P., Ellison, C., & Irazoqui, P. P. (2009) · Brain Research · doi:10.1016/j.brainres.2009.05.052 · Cited by 296 · see citing works
Mechanically-compliant intracortical implants reduce the neuroinflammatory response
Nguyen, J. K., Park, D. J., Skousen, J. L., Hess-Dunning, A. E., Tyler, D. J., Rowan, S. J., Weder, C., & Capadona, J. R. (2014) · Journal of Neural Engineering · doi:10.1088/1741-2560/11/5/056014 · Cited by 274 · see citing works
In vitro and in vivo evaluation of SU-8 biocompatibility
Nemani, K. V., Moodie, K. L., Brennick, J. B., Su, A., & Gimi, B. (2013) · Materials Science and Engineering C · doi:10.1016/j.msec.2013.07.001 · Cited by 264 · see citing works
Characterization of parylene C as an encapsulation material for implanted neural prostheses
Hassler, C., von Metzen, R. P., Ruther, P., & Stieglitz, T. (2010) · Journal of Biomedical Materials Research Part B Applied Biomaterials · doi:10.1002/jbm.b.31584 · Cited by 263 · see citing works
Electrodeposited iridium oxide for neural stimulation and recording electrodes
Meyer, R. D., Cogan, S. F., Nguyen, T. H., & Rauh, R. D. (2001) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/7333.918271 · Cited by 255 · see citing works
Self-citationSteigerwald, F., Müller, L., Johannes, S., et al. (2016) · Movement Disorders · doi:10.1002/mds.26669 · Cited by 242 · see citing works
Contarino, M. F., Bour, L. J., Verhagen, R., Lourens, M. A. J., de Bie, R. M. A., van den Munckhof, P., & Schuurman, P. R. (2014) · Neurology · doi:10.1212/wnl.0000000000000823 · Cited by 234 · see citing works
Rodeberg, N. T., Sandberg, S. G., Johnson, J. A., Phillips, P. E. M., & Wightman, R. M. (2017) · ACS Chemical Neuroscience · doi:10.1021/acschemneuro.6b00393 · Cited by 226 · see citing works
A carbon-fiber electrode array for long-term neural recording
Guitchounts, G., Markowitz, J. E., Liberti, W. A., & Gardner, T. J. (2013) · Journal of Neural Engineering · doi:10.1088/1741-2560/10/4/046016 · Cited by 224 · see citing works
Self-citationChronic In Vivo Evaluation of PEDOT/CNT for Stable Neural Recordings
Kozai, T. D. Y., Catt, K. A., Du, Z. J., Na, K., Srivannavit, O., Haque, R., Seymour, J. P., Wise, K. D., Yoon, E., & Cui, X. T. (2015) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2015.2445713 · Cited by 192 · see citing works
Sputtered iridium oxide films for neural stimulation electrodes
Cogan, S. F., Ehrlich, J., Plante, T. D., Smirnov, A., Shire, D. B., Gingerich, M. D., & Rizzo, J. F. (2008) · Journal of Biomedical Materials Research Part B Applied Biomaterials · doi:10.1002/jbm.b.31223 · Cited by 188 · see citing works
Self-citationSpencer, K. C., Sy, J. C., Ramadi, K. B., Graybiel, A. M., Langer, R., & Cima, M. J. (2017) · Scientific Reports · doi:10.1038/s41598-017-02107-2 · Cited by 184 · see citing works
Flexible, Penetrating Brain Probes Enabled by Advances in Polymer Microfabrication
Weltman, A., Yoo, J. J., & Meng, E. F. (2016) · Micromachines · doi:10.3390/mi7100180 · Cited by 180 · see citing works
Kozai, T. D. Y., Marzullo, T., Hooi, F. M., Langhals, N. B., Majewska, A. K., Brown, E. B., & Kipke, D. R. (2010) · Journal of Neural Engineering · doi:10.1088/1741-2560/7/4/046011 · Cited by 179 · see citing works
Plasma‐enhanced chemical vapor deposited silicon carbide as an implantable dielectric coating
Cogan, S. F., Edell, D. J., Guzelian, A. A., Liu, Y. P., & Edell, R. (2003) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.10152 · Cited by 170 · see citing works
Self-citationPatel, P. R., Na, K., Zhang, H., Kozai, T. D. Y., Kotov, N. A., Yoon, E., & Chestek, C. A. (2015) · Journal of Neural Engineering · doi:10.1088/1741-2560/12/4/046009 · Cited by 160 · see citing works
Stimuli-Responsive Mechanically Adaptive Polymer Nanocomposites
Shanmuganathan, K., Capadona, J. R., Rowan, S. J., & Weder, C. (2009) · ACS Applied Materials & Interfaces · doi:10.1021/am9006337 · Cited by 159 · see citing works
Measurement of the elastic modulus of nanostructured gold and platinum thin films
Salvadori, M. C., Brown, I. G., Vaz, A. R., Melo, L. L., & Cattani, M. (2003) · Physical review. B, Condensed matter · doi:10.1103/physrevb.67.153404 · Cited by 144 · see citing works
Thiol‐ene/acrylate substrates for softening intracortical electrodes
Ware, T. H., Simon, D., Liu, H. C., Musa, T., Vasudevan, S., Sloan, A. M., Keefer, E. W., Rennaker, R. L., & Voit, W. E. (2013) · Journal of Biomedical Materials Research Part B Applied Biomaterials · doi:10.1002/jbmb.32946 · Cited by 126 · see citing works
Helton, K. L., Ratner, B. D., & Wisniewski, N. A. (2011) · Journal of Diabetes Science and Technology · doi:10.1177/193229681100500317 · Cited by 125 · see citing works
Cho, C.-H. (2008) · Current Applied Physics · doi:10.1016/j.cap.2008.03.024 · Cited by 113 · see citing works
Compliant intracortical implants reduce strains and strain rates in brain tissuein vivo
Sridharan, A., Nguyen, J. K., Capadona, J. R., & Muthuswamy, J. (2015) · Journal of Neural Engineering · doi:10.1088/1741-2560/12/3/036002 · Cited by 112 · see citing works
Skousen, J. L., Merriam, S. M. E., Srivannavit, O., Perlin, G., Wise, K. D., & Tresco, P. A. (2011) · Progress in Brain Research · doi:10.1016/b978-0-444-53815-4.00009-1 · Cited by 111 · see citing works
Minnikanti, S., Diao, G., Pancrazio, J. J., Xie, X., Rieth, L. W., Solzbacher, F., & Peixoto, N. (2013) · Acta Biomaterialia · doi:10.1016/j.actbio.2013.10.031 · Cited by 107 · see citing works
Self-citationHsu, J.-M., Tathireddy, P., Rieth, L. W., Normann, A. R., & Solzbacher, F. (2007) · Thin Solid Films · doi:10.1016/j.tsf.2007.04.050 · Cited by 104 · see citing works
High Temperature Mechanical Properties of the Platinum Group Metals
Merker, J., Lupton, D. F., Töpfer, M., & Knake, H. (2001) · Platinum Metals Review · doi:10.1595/003214001x4527482 · Cited by 104 · see citing works
Helton, K. L., Ratner, B. D., & Wisniewski, N. A. (2011) · Journal of Diabetes Science and Technology · doi:10.1177/193229681100500318 · Cited by 102 · see citing works
Thin microelectrodes reduce GFAP expression in the implant site in rodent somatosensory cortex
Stice, P., Gilletti, A., Panitch, A., & Muthuswamy, J. (2007) · Journal of Neural Engineering · doi:10.1088/1741-2560/4/2/005 · Cited by 97 · see citing works
Hardness and elastic modulus of amorphous and nanocrystalline SiC and Si films
Kulikovsky, V., Vorlíček, V., Boháč, P., et al. (2007) · Surface and Coatings Technology · doi:10.1016/j.surfcoat.2007.07.029 · Cited by 92 · see citing works
Torab, K., Davis, T. S., Warren, D. J., House, P. A., Normann, R. A., & Greger, B. (2011) · Journal of Neural Engineering · doi:10.1088/1741-2560/8/3/035001 · Cited by 90 · see citing works
Cochlear nucleus auditory prostheses
McCreery, D. B. (2008) · Hearing Research · doi:10.1016/j.heares.2007.11.014 · Cited by 88 · see citing works
Evaluation of the stability of intracortical microelectrode arrays
Liu, X., McCreery, D. B., Bullara, L. A., & Agnew, W. F. (2006) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2006.870495 · Cited by 84 · see citing works
Mandal, H. S., Knaack, G. L., Charkhkar, H., McHail, D. G., Kastee, J. S., Dumas, T. C., Peixoto, N., Rubinson, J. F., & Pancrazio, J. J. (2014) · Acta Biomaterialia · doi:10.1016/j.actbio.2014.02.029 · Cited by 72 · see citing works
Self-citationFekete, Z., & Pongracz, A. (2016) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2016.12.096 · Cited by 72 · see citing works
SiC protective coating for photovoltaic retinal prosthesis
Lei, X., Kane, S. R., Cogan, S. F., Lorach, H., Galambos, L., Huie, P., Mathieson, K., Kamins, T. I., Harris, J. S., & Palanker, D. (2016) · Journal of Neural Engineering · doi:10.1088/1741-2560/13/4/046016 · Cited by 64 · see citing works
Self-citationDesign and demonstration of an intracortical probe technology with tunable modulus
Simon, D., Charkhkar, H., John, C. S., Rajendran, S. H., Kang, T. H., Reit, R., Arreaga‐Salas, D., McHail, D. G., Knaack, G. L., Sloan, A. M., et al. (2016) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.35896 · Cited by 59 · see citing works
Self-citationClinical outcomes of silicon carbide coated stents in patients with coronary artery disease.
Kalnins, U., Ērglis, A., Dinne, I., et al. (2002) · PubMed · Cited by 57 · see citing works
Han, M., Manoonkitiwongsa, P. S., Wang, C. X., & McCreery, D. B. (2011) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2011.2172440 · Cited by 54 · see citing works
In vivo Characterization of Amorphous Silicon Carbide As a Biomaterial for Chronic Neural Interfaces
Knaack, G. L., McHail, D. G., Borda, G., Koo, B., Peixoto, N., Cogan, S. F., Dumas, T. C., & Pancrazio, J. J. (2016) · Frontiers in Neuroscience · doi:10.3389/fnins.2016.00301 · Cited by 51 · see citing works
Self-citationImproved Poly(3,4-Ethylenedioxythiophene) (PEDOT) for Neural Stimulation
Mandal, H. S., Kastee, J. S., McHail, D. G., Rubinson, J. F., Pancrazio, J. J., & Dumas, T. C. (2015) · Neuromodulation Technology at the Neural Interface · doi:10.1111/ner.12285 · Cited by 43 · see citing works
Self-citationTeplitzky, B. A., Verbick, L. Z., Xiao, Y., & Johnson, M. D. (2016) · Frontiers in Computational Neuroscience · doi:10.3389/fncom.2016.00058 · Cited by 43 · see citing works
Silicon carbide coated MEMS strain sensor for harsh environment applications
Azevedo, R. G., Zhang, J., Jones, D. G., et al. (2007) · Proceedings, IEEE micro electro mechanical systems · doi:10.1109/memsys.2007.4433166 · Cited by 38 · see citing works
Sanders, J. E., Cassisi, D. V., Neumann, T., Golledge, S. L., Zachariah, S. G., Ratner, B. D., & Bale, S. D. (2003) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.10525 · Cited by 35 · see citing works
Xiao, Y., Peña, E., & Johnson, M. D. (2015) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2015.2457873 · Cited by 34 · see citing works
Carbon Nanofiber Electrode for Neurochemical Monitoring
Zhang, D. A., Rand, E., Marsh, M., et al. (2013) · Molecular Neurobiology · doi:10.1007/s12035-013-8531-6 · Cited by 33 · see citing works
Forcelli, P. A., Sweeney, C., Kammerich, A. D., Lee, B. C. ‐., Rubinson, L. H., Kayinamura, Y. P., Gale, K., & Rubinson, J. F. (2012) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.34285 · Cited by 29 · see citing works
Output Properties of the Cortical Hindlimb Motor Area in Spinal Cord-Injured Rats
Frost, S. B., Dunham, C., Barbay, S., Krizsan‐Agbas, D., Winter, M. K., Guggenmos, D. J., & Nudo, R. J. (2015) · Journal of Neurotrauma · doi:10.1089/neu.2015.3961 · Cited by 24 · see citing works
Silicon Carbide as a Material for Biomedical Microsystems
Zorman, C. A. (2009) · Cited by 24 · see citing works
Nanocoaxes for optical and electronic devices
Rizal, B., Merlo, J. M., Burns, M. J., et al. (2014) · The Analyst · doi:10.1039/c4an01447b · Cited by 16 · see citing works
Paralikar, K. J., Neuberger, T., Matsui, J. T., Barber, A. J., WEBB, A. G., & Clement, R. S. (2009) · Journal of Neural Engineering · doi:10.1088/1741-2560/6/3/034001 · Cited by 4 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
Fernández, E., Alfaro, A., Soto-Sánchez, C., Gonzalez-Lopez, P., Lozano, A. M., Peña, S., Grima, M. D., Rodil, A., Gómez, B., Chen, X., et al. (2021) · Journal of Clinical Investigation · doi:10.1172/jci151331 · Cited by 250 · see citing works
Gulino, M., Kim, D., Pané, S., Santos, S. D., & Pêgo, A. P. (2019) · Frontiers in Neuroscience · doi:10.3389/fnins.2019.00689 · Cited by 159 · see citing works
Development of visual Neuroprostheses: trends and challenges.
Fernandez, E. (2018) · Bioelectronic Medicine · doi:10.1186/s42234-018-0013-8 · Cited by 114 · see citing works
From softening polymers to multimaterial based bioelectronic devices
Ecker, M., Joshi-Imre, A., Modi, R., Frewin, C. L., Garcia-Sandoval, A., Maeng, J., Gutierrez-Heredia, G., Pancrazio, J. J., & Voit, W. E. (2019) · Multifunctional Materials · doi:10.1088/2399-7532/aaed58 · Cited by 34 · see citing works
Self-citation
- Authors
- Pancrazio, J. J., Deku, F., Ghazavi, A., Stiller, A. M., Rihani, R., Frewin, C. L., Varner, V. D., Gardner, T. J., & Cogan, S. F.
- Affiliations
- The University of Texas at Dallas (US)
- Boston University (US)
- Corresponding author
- Pancrazio, Joseph J.
- ORCID
- Venue
- Neuromodulation: Technology at the Neural Interface
- Publisher
- Elsevier BV
- Published
- 2017-12
- Volume
- 20
- Issue
- 8
- Pages
- 745-752
- ISSN
- 1094-7159 (ISSN-L)
- PMC
- PMC5943060
- OpenAlex
- W2765606955
- Cited by
- 60
- References
- 80
- Citations by year
- 2026: 2 · 2025: 2 · 2024: 5 · 2023: 6 · 2022: 8 · 2021: 9 · 2020: 8 · 2019: 6 · 2018: 14
- FWCI
- 0.94
- Type
- journal article
- Language
- en
- Open access
- green
- europepmc.org
- Locations
- Neuromodulation Technology at the Neural Interface (publishedVersion)
- PubMed (publishedVersion)
- Europe PMC (PubMed Central) (acceptedVersion)
- PubMed Central (acceptedVersion)
- Funders
- Defense Advanced Research Projects Agency (HR0011‐15‐2‐0017)
- National Institutes of Health (U01NS090454‐01)
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Physical Sciences › Engineering › Biomedical Engineering › Analog and Mixed-Signal Circuit Design
- Health Sciences › Medicine › Neurology › Neurological disorders and treatments
- Keywords
- microelectrodes, ultramicroelectrodes, neurostimulation, implantable neural interfaces, foreign body reaction, implant size, thin film devices, amorphous silicon carbide, polymer coatings, charge capacity, neural recording
- MeSH terms
- Animals, Electrodes, Implanted, Equipment Design, Humans, Microelectrodes, Neurons
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review