The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Peripheral nerve regeneration by microbraided poly(L‐lactide‐co‐glycolide) biodegradable polymer fibers
Abstract
Tiny tubes with fiber architecture were developed by a novel method of fabrication upon introducing some modification to the microbraiding technique, to function as nerve guide conduit and the feasibility of in vivo nerve regeneration was investigated through several of these conduits. Poly(L‐lactide‐co‐glycolide) (10:90) polymer fibers being biocompatible and biodegradable were used for the fabrication of the conduits. The microbraided nerve guide conduits (MNGCs) were characterized using scanning electron microscopy to study the surface morphology and fiber arrangement. Degradation tests were performed and the micrographs of the conduit showed that the degradation of the conduit is by fiber breakage indicating bulk hydrolysis of the polymer. Biological performances of the conduits were examined in the rat sciatic nerve model with a 12‐mm gap. After implantation of the MNGC to the right sciatic nerve of the rat, there was no inflammatory response. One week after implantation, a thin tissue capsule was formed on the outer surface of the conduit, indicating good biological response of the conduit. Fibrin matrix cable formation was seen inside the MNGC after 1 week implantation. One month after implantation, 9 of 10 rats showed successful nerve regeneration. None of the implanted tubes showed tube breakage. The MNGCs were flexible, permeable, and showed no swelling apart from its other advantages. Thus, these new poly(L‐lactide‐co‐glycolide) microbraided conduits can be effective aids for nerve regeneration and repair and may lead to clinical applications. © 2003 Wiley Periodicals, Inc. J Biomed Mater Res 68A: 286–295, 2004
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Widmer, M. S., Gupta, P. K., Lu, L., Meszlenyi, R. K., Evans, G. R. D., Brandt, K., Savel, T., Gurlek, A., Patrick, C. W., & Mikos, A. G. (1998) · Biomaterials · doi:10.1016/s0142-9612(98)00099-4 · Cited by 372
Cited by
Schnell, E., Klinkhammer, K., Balzer, S., Brook, G., Klee, D., Dalton, P., & Mey, J. (2007) · Biomaterials · doi:10.1016/j.biomaterials.2007.03.009 · Cited by 727
Neural tissue engineering options for peripheral nerve regeneration
Gu, X., Ding, F., & Williams, D. F. (2014) · Biomaterials · doi:10.1016/j.biomaterials.2014.04.064 · Cited by 630
Subramanian, A., Krishnan, U. M., & Sethuraman, S. (2009) · Journal of Biomedical Science · doi:10.1186/1423-0127-16-108 · Cited by 599
Gu, X., Ding, F., Yang, Y., & Liu, J. (2011) · Progress in Neurobiology · doi:10.1016/j.pneurobio.2010.11.002 · Cited by 583
Repairing injured peripheral nerves: Bridging the gap
Deumens, R., Bozkurt, A., Meek, M. F., Marcus, M. A. E., Joosten, E. A. J., Weis, J., & Brook, G. A. (2010) · Progress in Neurobiology · doi:10.1016/j.pneurobio.2010.10.002 · Cited by 510
Enhancement of neurite outgrowth using nano-structured scaffolds coupled with laminin
Koh, H. S., Yong, T., Chan, C. K., & Ramakrishna, S. (2008) · Biomaterials · doi:10.1016/j.biomaterials.2008.05.014 · Cited by 493
Self-citationElectrospinning of polymer nanofibers for tissue regeneration
Jiang, T., Carbone, E. J., Lo, K. W.-H., & Laurencin, C. T. (2015) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2014.12.001 · Cited by 487
Effects of Humidity and Solution Viscosity on Electrospun Fiber Morphology
Nezarati, R. M., Eifert, M. B., & Cosgriff-Hernandez, E. (2013) · Tissue Engineering Part C: Methods · doi:10.1089/ten.tec.2012.0671 · Cited by 459
The role of aligned polymer fiber-based constructs in the bridging of long peripheral nerve gaps
Kim, Y.-T., Haftel, V. K., Kumar, S., & Bellamkonda, R. V. (2008) · Biomaterials · doi:10.1016/j.biomaterials.2008.03.042 · Cited by 451
Current applications and future perspectives of artificial nerve conduits
Jiang, X., Lim, S. H., Mao, H.-Q., & Chew, S. Y. (2010) · Experimental Neurology · doi:10.1016/j.expneurol.2009.09.009 · Cited by 394
Electrospun nanofibers for neural tissue engineering
Xie, J., MacEwan, M. R., Schwartz, A. G., & Xia, Y. (2010) · Nanoscale · doi:10.1039/b9nr00243j · Cited by 378
Panseri, S., Cunha, C., Lowery, J., Del Carro, U., Taraballi, F., Amadio, S., Vescovi, A., & Gelain, F. (2008) · BMC Biotechnology · doi:10.1186/1472-6750-8-39 · Cited by 321
Aligned PLLA nanofibrous scaffolds coated with graphene oxide for promoting neural cell growth
Zhang, K., Zheng, H., Liang, S., & Gao, C. (2016) · Acta Biomaterialia · doi:10.1016/j.actbio.2016.04.008 · Cited by 261
Materials for Peripheral Nerve Regeneration
Ciardelli, G., & Chiono, V. (2006) · Macromolecular Bioscience · doi:10.1002/mabi.200500151 · Cited by 255
Dong, X., Liu, S., Yang, Y., Gao, S., Li, W., Cao, J., Wan, Y., Huang, Z., Fan, G., Chen, Q., et al. (2021) · Biomaterials · doi:10.1016/j.biomaterials.2021.120767 · Cited by 167
Self-citationSananpanich, K., Wiwattanapanich, K., Daranarong, D., Namhongsa, M., Jringjit, W., Pleumsamran, A., Chaisuksunt, V., Chaisri, W., Chattipakorn, N., & Punyodom, W. (2025) · ACS Omega · doi:10.1021/acsomega.4c10800
Metadata
- Authors
- Bini, T. B., Gao, S., Xu, X., Wang, S., Ramakrishna, S., & Leong, K. W.
- Venue
- Journal of Biomedical Materials Research Part A
- Publisher
- Wiley
- Published
- 2003-12-15
- Volume
- 68A
- Issue
- 2
- Pages
- 286-295
- ISSN
- 1549-3296 (ISSN-L)
- 1552-4965
- OpenAlex
- W1968944127
- Cited by
- 167
- References
- 1
- FWCI
- 1.89
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.