Lubrication and wear properties of grafted polyelectrolytes, hyaluronan and hylan, measured in the surface forces apparatus
Abstract
Hyaluronan is believed to have an important function in the boundary biolubrication of articular cartilage. Using a Surface Forces Apparatus, we tested the tribological properties of surface bound, rather than “free” hyaluronan. The grafting process of the polyelectrolyte included either a biological route via an HA‐binding protein or a chemical reaction to covalently bind the polymer to a lipid bilayer coated surface. In another reaction, we constructed a surface with covalently grafted hylan (crosslinked hyaluronan). We studied the normal and shear forces between these surfaces. None of the systems demonstrated comparable lubrication to that found between cartilage surfaces except at very low loads. Both grafted hyaluronan and hylan generated coefficients of friction between 0.15 and 0.3. Thus, the polysaccharide, which is a constituent of the lamina splendens (outermost cartilage layer), is not expected to be the responsible molecule for the great lubricity of cartilage; however, it may contribute to the load bearing and wear protection of these surfaces. This was concluded from the results with hylan, where a thin gel layer was sufficient to shield the underlying surfaces from damage even at applied pressures of over 200 atmospheres during shear. Our study shows that a low coefficient of friction is not a requirement for, or necessarily a measure of, wear protection. © 2004 Wiley Periodicals, Inc. J Biomed Mater Res 71A: 6–15, 2004
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The relatively poor lubrication of HA is in line with an earlier study and may be due to poor hydration of the charged COO- groups on HA.
“The relatively poor lubrication is however in line with the conclusions of an earlier study on HA lubrication to much higher pressures [113] and may be due to poor hydration of the charged groups ( COO ) on the HA, as discussed below.”
From Hydration lubrication (2013) · cites this paper as [113]
Cites
Lubrication by charged polymers
Raviv, U., Giasson, S., Kampf, N., Gohy, J.-F., Jérôme, R., & Klein, J. (2003) · Nature · doi:10.1038/nature01970 · Cited by 910 · see citing works
Surfactants identified in synovial fluid and their ability to act as boundary lubricants.
Hills, B. A., & Butler, B. D. (1984) · Annals of the Rheumatic Diseases · doi:10.1136/ard.43.4.641 · Cited by 177 · see citing works
Kampf, N., Raviv, U., & Klein, J. (2004) · Macromolecules · doi:10.1021/ma0303263 · Cited by 85 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
Klein, J. (2013) · Friction · doi:10.1007/s40544-013-0001-7 · Cited by 567 · see citing works
Lubrication of Articular Cartilage
Jahn, S., Seror, J., & Klein, J. (2016) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-081514-123305 · Cited by 406 · see citing works
Zappone, B., Ruths, M., Greene, G. W., Jay, G. D., & Israelachvili, J. N. (2007) · Biophysical Journal · doi:10.1529/biophysj.106.088799 · Cited by 341 · see citing works
Self-citationSeror, J., Merkher, Y., Kampf, N., Collinson, L., Day, A. J., Maroudas, A., & Klein, J. (2011) · Biomacromolecules · doi:10.1021/bm2004912 · Cited by 159 · see citing works
- Authors
- Benz, M., Chen, N., & Israelachvili, J.
- Affiliations
- University of California, Santa Barbara (US)
- Corresponding author
- Israelachvili, Jacob
- ORCID
- Israelachvili, Jacob
- Venue
- Journal of Biomedical Materials Research Part A
- Publisher
- Wiley
- Published
- 2004-08-05
- Volume
- 71A
- Issue
- 1
- Pages
- 6-15
- ISSN
- 1549-3296 (ISSN-L)
- 1552-4965
- OpenAlex
- W2049868099
- Cited by
- 161
- References
- 3
- Citations by year
- 2026: 8 · 2025: 9 · 2024: 5 · 2023: 2 · 2022: 3 · 2021: 5 · 2020: 7 · 2019: 9 · 2018: 7 · 2017: 7 · 2016: 5 · 2015: 7 · 2014: 11 · 2013: 11 · 2012: 8
- FWCI
- 3.98
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Journal of Biomedical Materials Research Part A (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Rheumatology › Osteoarthritis Treatment and Mechanisms
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Cell Biology › Proteoglycans and glycosaminoglycans research
- Physical Sciences › Engineering › Mechanical Engineering › Lubricants and Their Additives
- Keywords
- hyaluronic acid, boundary lubrication, articular cartilage, tribology, friction coefficient, wear protection, shear force, normal force, gel layer
- MeSH terms
- Aluminum Silicates, Biocompatible Materials, Cartilage, Articular, Hyaluronic Acid, Lipid Bilayers, Lubrication, Materials Testing, Stress, Mechanical, Surface Properties, Viscosity, Molecular Structure, Shear Strength
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review