The DOI matches its Crossref record.
High surface energy enhances cell response to titanium substrate microstructure
Abstract
Titanium (Ti) is used for implantable devices because of its biocompatible oxide surface layer. TiO 2 surfaces that have a complex microtopography increase bone‐to‐implant contact and removal torque forces in vivo and induce osteoblast differentiation in vitro. Studies examining osteoblast response to controlled surface chemistries indicate that hydrophilic surfaces are osteogenic, but TiO 2 surfaces produced until now exhibit low surface energy because of adsorbed hydrocarbons and carbonates from the ambient atmosphere or roughness induced hydrophobicity. Novel hydroxylated/hydrated Ti surfaces were used to retain high surface energy of TiO 2. Osteoblasts grown on this modified surface exhibited a more differentiated phenotype characterized by increased alkaline phosphatase activity and osteocalcin and generated an osteogenic microenvironment through higher production of PGE 2 and TGF‐β1. Moreover, 1α,25(OH)2 D 3 increased these effects in a manner that was synergistic with high surface energy. This suggests that increased bone formation observed on modified Ti surfaces in vivo is due in part to stimulatory effects of high surface energy on osteoblasts. © 2005 Wiley Periodicals, Inc. J Biomed Mater Res, 2005
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Surface treatments of titanium dental implants for rapid osseointegration
Le Guéhennec, L., Soueidan, A., Layrolle, P., & Amouriq, Y. (2007) · Dental Materials · doi:10.1016/j.dental.2006.06.025 · Cited by 2,406
Bacakova, L., Filova, E., Parizek, M., Ruml, T., & Svorcik, V. (2011) · Biotechnology Advances · doi:10.1016/j.biotechadv.2011.06.004 · Cited by 1,000
Gittens, R. A., McLachlan, T., Olivares-Navarrete, R., Cai, Y., Berner, S., Tannenbaum, R., Schwartz, Z., Sandhage, K. H., & Boyan, B. D. (2011) · Biomaterials · doi:10.1016/j.biomaterials.2011.01.029 · Cited by 827
Self-citationImpact of Dental Implant Surface Modifications on Osseointegration
Smeets, R., Stadlinger, B., Schwarz, F., Beck-Broichsitter, B., Jung, O., Precht, C., Kloss, F., Gröbe, A., Heiland, M., & Ebker, T. (2016) · BioMed Research International · doi:10.1155/2016/6285620 · Cited by 701
Dendritic cell responses to surface properties of clinical titanium surfaces
Kou, P. M., Schwartz, Z., Boyan, B. D., & Babensee, J. E. (2011) · Acta Biomaterialia · doi:10.1016/j.actbio.2010.10.020 · Cited by 73
Self-citationCanullo, L., Rakic, M., Corvino, E., Burton, M., Krumbeck, J. A., Chittoor Prem, A., Ravidà, A., Ignjatović, N., Sculean, A., Menini, M., et al. (2023) · BMC Oral Health · doi:10.1186/s12903-023-02729-1 · Cited by 19
Surface-modified titanium to enhance osseointegration in dental implants
SARINNAPHAKORN, L., & DI SILVIO, L. (2009) · Cellular Response to Biomaterials · doi:10.1533/9781845695477.3.572 · Cited by 4
Metadata
- Authors
- Zhao, G., Schwartz, Z., Wieland, M., Rupp, F., Geis‐Gerstorfer, J., Cochran, D. L., & Boyan, B. D.
- Venue
- Journal of Biomedical Materials Research Part A
- Publisher
- Wiley
- Published
- 2005-05-27
- Volume
- 74A
- Issue
- 1
- Pages
- 49-58
- ISSN
- 1549-3296 (ISSN-L)
- 1552-4965
- OpenAlex
- W2010278203
- Cited by
- 922
- References
- 0
- FWCI
- 15.42
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.