Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 170

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Local delivery of bisphosphonate from coated orthopedic implants increases implants mechanical stability in osteoporotic rats

Open access
Peter, Bastian, Gauthier, Olivier, Laïb, Samia, Bujoli, Bruno, Guicheux, Jérôme, Janvier, Pascal, van Lenthe, G. Harry, Müller, Ralph, Zambelli, Pierre‐Yves, Bouler, Jean‐Michel, Pioletti, Dominique P.·2006·Journal of Biomedical Materials Research Part A

Abstract

Patients with osteoporosis and joint disabilities represent a constant growing and challenging population to be treated in the musculoskeletal clinical field. Especially in the case of total hip arthroplasty, new solutions should be developed to compensate for the double negative factors, peri‐implant osteolysis, and osteoporotic bone loss, affecting the quality of implant outcome. The goal of this study was then to establish a proof of concept for orthopedic implant used as Zoledronate delivery in osteoporotic rats, and in particular, to verify if this approach could increase the initial implant stability. Twenty‐five female 6‐month‐old Wistar rats were ovariectomized 6 weeks before the implantation to induce osteoporosis. The animals were randomly separated in five groups representing the different Zoledronate concentrations in the HA coating: 0, 0.2, 2.1, 8.5, and 16 μg/implant. Histomorphometric measures and peri‐implant bone volume fraction were assessed and mechanical stability tests were performed. Bone volume fraction and biomechanical results clearly illustrate the positive effect of Zoledronate coated implants in the osteoporotic rats. A remarkable result was to show the existence of a window of Zoledronate content (0.2 to 8.5 μg/implant) in which the mechanical fixation of the implant increased. We were able to establish the proof of concept for orthopedic implants used as a drug delivery system in osteoporotic rats. The local bisphosphonate delivery from a calcium phosphate coating allowed increase of the mechanical fixation of an orthopedic implant. This study shows that orthopedic implants containing bisphosphonates could be beneficial for osteoporotic patients in need of a total joint replacement. © 2005 Wiley Periodicals, Inc. J Biomed Mater Res, 2006

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/jbm.a.30456

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 170

Metadata

Authors
Peter, B., Gauthier, O., Laïb, S., Bujoli, B., Guicheux, J., Janvier, P., van Lenthe, G. H., Müller, R., Zambelli, P., Bouler, J., & Pioletti, D. P.
Venue
Journal of Biomedical Materials Research Part A
Publisher
Wiley
Published
2005-10-27
Volume
76A
Issue
1
Pages
133-143
ISSN
  • 1549-3296 (ISSN-L)
  • 1552-4965
OpenAlex
W2109446452
Cited by
170
References
1
FWCI
5.29
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Local delivery of bisphosphonate from coated orthopedic implants increases implants mechanical stability in osteoporotic rats. https://app.cochat.ai/papers/10.1002/jbm.a.30456
The paper
Peter, B., Gauthier, O., Laïb, S., Bujoli, B., Guicheux, J., Janvier, P., van Lenthe, G. H., Müller, R., Zambelli, P., Bouler, J., & Pioletti, D. P. (2006). Local delivery of bisphosphonate from coated orthopedic implants increases implants mechanical stability in osteoporotic rats. Journal of Biomedical Materials Research Part A. https://doi.org/10.1002/jbm.a.30456

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.