Macroporous condensed poly(tetrafluoroethylene). I. In vivo inflammatory response and healing characteristics
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
This study was designed to determine whether the novel spatial geometry of macroporous condensed poly(tetrafluoroethylene) (cPTFE) favorably affects the in vivo repair process. Specifically, the macroporous surface geometry and the reduced material thickness contribute to better healing characteristics. For this purpose, three other materials used for abdominal wall repair were selected, expanded poly(tetrafluoroethylene) (ePTFE), low‐weight poly(propylene) (lwPP), and high‐weight poly(propylene) (hwPP). Samples of each material (1 × 2 cm, n = 4) were implanted subcutaneously in rats for 7, 28, or 56 days. After sacrificing the animals, at each time point, the tissue implant sites were subjected to morphometric analysis and evaluation of inflammatory and wound‐healing tissue characteristics. Although the fibrous capsule thickness did not significantly vary among the four materials (p > 0.05), cPTFE consistently led to the most mature fibrous capsule. However, ePTFE showed the greatest tissue–material integration. Both PP materials presented various levels of tissue integration, but they were characterized by significant early inflammation and increased foreign body reaction around the mesh openings, especially for hwPP. In contrast, cPTFE did not induce extensive inflammation or elevated foreign body reaction around its mesh openings. We conclude that cPTFE combines the inherent PTFE biocompatibility with low polymer surface area (large mesh openings, reduced material thickness) leading to a better inflammatory and wound healing response compared to available materials used in abdominal wall reconstruction. © 2005 Wiley Periodicals, Inc. J Biomed Mater Res, 2006
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Ward, W. K., Slobodzian, E. P., Tiekotter, K. L., & Wood, M. D. (2002) · Biomaterials · doi:10.1016/s0142-9612(02)00160-6 · Cited by 176
Cited by
Characterization of topographical effects on macrophage behavior in a foreign body response model
Chen, S., Jones, J. A., Xu, Y., Low, H.-Y., Anderson, J. M., & Leong, K. W. (2010) · Biomaterials · doi:10.1016/j.biomaterials.2010.01.074 · Cited by 389
“Surface chemistry [8–11], roughness [12,13], substrate stiffness [14,15], and geometry [16] have also been altered to study their effects on cell adhesion and responses associated with foreign body reaction.”
Self-citationMechanical properties of the abdominal wall and biomaterials utilized for hernia repair
Deeken, C. R., & Lake, S. P. (2017) · Journal of the Mechanical Behavior of Biomedical Materials · doi:10.1016/j.jmbbm.2017.05.008 · Cited by 258
Cao, H., Mchugh, K., Chew, S. Y., & Anderson, J. M. (2010) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.32609 · Cited by 243
Self-citationHuang, Y., Wu, C., Zhang, X., Chang, J., & Dai, K. (2018) · Acta Biomaterialia · doi:10.1016/j.actbio.2017.08.044 · Cited by 203
In vivo kinetic degradation analysis and biocompatibility of aliphatic polyester polyurethanes
Knight, P. T., Kirk, J. T., Anderson, J. M., & Mather, P. T. (2010) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.32806 · Cited by 27
Self-citation
Metadata
- Authors
- Voskerician, G., Gingras, P. H., & Anderson, J. M.
- Venue
- Journal of Biomedical Materials Research Part A
- Publisher
- Wiley
- Published
- 2005-08-22
- Volume
- 76A
- Issue
- 2
- Pages
- 234-242
- ISSN
- 1549-3296 (ISSN-L)
- 1552-4965
- OpenAlex
- W1964200563
- Cited by
- 50
- References
- 1
- FWCI
- 3.24
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.