The effect of microgeometry, implant thickness and polyurethane chemistry on the foreign body response to subcutaneous implants

The DOI matches its Crossref record; 25 of the 28 references it cites were found in a registry or an index.

Abstract

We addressed the effect of implant thickness, implant porosity, and polyurethane (PU) chemistry on angiogenesis and on the foreign body response in rats. The following materials were implanted subcutaneously for 7 weeks then excised for histologic analysis: a solid PU; a solid polyurethane with silicone and polyethylene oxide (PU-S-PEO); porous expanded polytetrafluoroethylene (ePTFE); and porous polyvinyl alcohol sponge (PVA). Two thicknesses of PU-S-PEO were compared: 300 microns (thin) and 2000 microns (thick). Foreign body capsule (FBC) thickness was much less in PU-S-PEO implants than in PU implants. In addition, FBC were thinner in thin implants than in thick implants. FBC was much more dense in solid implants than in porous implants. As compared with solid implants, porous implants (PVA and ePTFE) led to a marked increase in the number of microvessels that developed adjacent to the implant, as observed both with hematoxylin/eosin staining and with an immunohistochemical anti-endothelial stain. We conclude that the polyethylene oxide and silicone moieties in PU reduce the thickness of the subsequent FBC. In addition, thin implants lead to a thin FBC. Porous implants (PVA and ePTFE) cause more angiogenesis than solid implants. These results may have implications for the measurement of blood-derived analytes by biosensors.

Overview

Integrity signals

Registry

Crossref · 10.1016/s0142-9612(02)00160-6

Cites

25 of 25 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

1 more claim about this paper

Create a free account to see every claim other papers make about this one.

See all claims — free account

Citations

Cites

Show all 25 references

Research works printed but not linked: 1

  1. Sharkawy, 1998, Engineering the tissue which encapsulates subcutaneous implants. III. Effective tissue response times, J Biomed Mater Res, 40, 598, 10.1002/(sici)1097-4636(19980615)40:4<598::aid-jbm11>3.0.co;2-c · DOI · Paper page

Cited by

See all 176

Metadata

Authors
Ward, W. K., Slobodzian, E. P., Tiekotter, K. L., & Wood, M. D.
Affiliations
Legacy Health (US)
Corresponding author
Ward, W.Kenneth
Venue
Biomaterials
Publisher
Elsevier BV
Published
2002-11
Volume
23
Issue
21
Pages
4185-4192
ISSN
0142-9612 (ISSN-L)
OpenAlex
W2051278851
Cited by
176
References
28
Citations by year
2026: 2 · 2025: 10 · 2024: 8 · 2023: 11 · 2022: 9 · 2021: 15 · 2020: 11 · 2019: 7 · 2018: 7 · 2017: 7 · 2016: 7 · 2015: 10 · 2014: 4 · 2013: 10 · 2012: 7
FWCI
4.49
Type
journal article
Language
en
Open access
closed
Licence
  • www.elsevier.com/tdm/userlicense/1.0/ (tdm)
  • www.elsevier.com/legal/tdmrep-license (tdm)
Locations
  • Biomaterials (publishedVersion)
  • PubMed (publishedVersion)
Funders
  • National Institutes of Health (5r01dk055297-03)
  • National Institute of Diabetes and Digestive and Kidney Diseases (R01 DK55297)
Topics
  • Health Sciences › Medicine › Surgery › Tissue Engineering and Regenerative Medicine
  • Physical Sciences › Materials Science › Surfaces, Coatings and Films › Polymer Surface Interaction Studies
  • Physical Sciences › Materials Science › Biomaterials › Hydrogels: synthesis, properties, applications
Keywords
foreign body reaction, subcutaneous implants, polyurethane, implant thickness, angiogenesis, poly(ethylene oxide), silicone, porous implants, expanded polytetrafluoroethylene, polyvinyl alcohol sponge, microgeometry, biosensors
MeSH terms
Animals, Biocompatible Materials, Foreign-Body Reaction, Male, Microscopy, Electron, Scanning, Polyethylene Glycols, Polytetrafluoroethylene, Polyurethanes, Polyvinyl Alcohol, Porosity, Rats, Sprague-Dawley, Neovascularization, Physiologic, Prostheses and Implants, Subcutaneous Tissue, Rats

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: The effect of microgeometry, implant thickness and polyurethane chemistry on the foreign body response to subcutaneous implants. https://app.cochat.ai/papers/10.1016/s0142-9612(02)00160-6
The paper
Ward, W. K., Slobodzian, E. P., Tiekotter, K. L., & Wood, M. D. (2002). The effect of microgeometry, implant thickness and polyurethane chemistry on the foreign body response to subcutaneous implants. Biomaterials. https://doi.org/10.1016/s0142-9612(02)00160-6

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.