The DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.
Hydroxyapatite growth on anodic TiO2 nanotubes
Abstract
In the present work, we study the growth of hydroxyapatite formation on different TiO 2 nanotube layers. The nanotube layers were fabricated by electrochemical anodization of titanium in fluoride‐containing electrolytes. To study various nanotube lengths, layers with an individual tube diameter of 100 nm were grown to a thickness of approximately 2 μm or 500 nm. The ability to form apatite on the nanotube layers was examined by immersion tests combined with SEM, XRD and FT‐IR investigations. For reference, experiments were also carried out on compact anodic TiO 2 layers. The results clearly show that the presence of the nanotubes on a titanium surface enhances the apatite formation and that the 2‐μm thick nanotube layer triggers deposition faster than the thinner layers. Tubes annealed to anatase, or a mixture of anatase and rutile are clearly more efficient in promoting apatite formation than the tubes in their “as‐formed” amorphous state. © 2006 Wiley Periodicals, Inc. J Biomed Mater Res, 2006
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Surface modification of titanium, titanium alloys, and related materials for biomedical applications
LIU, X., CHU, P., & DING, C. (2004) · Materials Science and Engineering: R: Reports · doi:10.1016/j.mser.2004.11.001 · Cited by 3,487
Lowenstam, H. A., & Weiner, S. (1989) · doi:10.1093/oso/9780195049770.001.0001 · Cited by 2,090
Titanium oxide nanotube arrays prepared by anodic oxidation
Gong, D., Grimes, C. A., Varghese, O. K., Hu, W., Singh, R. S., Chen, Z., & Dickey, E. C. (2001) · Journal of Materials Research · doi:10.1557/jmr.2001.0457 · Cited by 2,041
Novel bioactive materials with different mechanical properties
Kokubo, T., Kim, H.-M., & Kawashita, M. (2003) · Biomaterials · doi:10.1016/s0142-9612(03)00044-9 · Cited by 1,914
Buser, D., Schenk, R. K., Steinemann, S., Fiorellini, J. P., Fox, C. H., & Stich, H. (1991) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820250708 · Cited by 1,719
Synthesis and characterization of hydroxyapatite crystals: A review study on the analytical methods
Koutsopoulos, S. (2002) · Journal of Biomedical Materials Research · doi:10.1002/jbm.10280 · Cited by 1,636
Brunette, D. M., Tengvall, P., Textor, M., & Thomsen, P. (2001) · Engineering Materials · doi:10.1007/978-3-642-56486-4 · Cited by 1,547
High‐Aspect‐Ratio TiO2 Nanotubes by Anodization of Titanium
Macák, J. M., Tsuchiya, H., & Schmuki, P. (2005) · Angewandte Chemie International Edition · doi:10.1002/anie.200462459 · Cited by 1,184
Self-citationThe role of hydrated silica, titania, and alumina in inducing apatite on implants
Li, P., Ohtsuki, C., Kokubo, T., Nakanishi, K., Soga, N., & de Groot, K. (1994) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820280103 · Cited by 735
Preparation of bioactive titanium metal via anodic oxidation treatment
Yang, B., Uchida, M., Kim, H.-M., Zhang, X., & Kokubo, T. (2004) · Biomaterials · doi:10.1016/s0142-9612(03)00626-4 · Cited by 730
Structural dependence of apatite formation on titania gels in a simulated body fluid
Uchida, M., Kim, H., Kokubo, T., Fujibayashi, S., & Nakamura, T. (2002) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.10414 · Cited by 478
Biomimetic apatite formation on chemically treated titanium
Jonášová, L., Müller, F. A., Helebrant, A., Strnad, J., & Greil, P. (2004) · Biomaterials · doi:10.1016/j.biomaterials.2003.08.009 · Cited by 474
Self-citationCalcium phosphate naturally formed on titanium in electrolyte solution
Hanawa, T., & Mamoru, O. T. A. (1991) · Biomaterials · doi:10.1016/0142-9612(91)90028-9 · Cited by 457
The interface zone of inorganic implantsIn vivo: Titanium implants in bone
Albrektsson, T., Brånemark, P.-I., Hansson, H.-A., Kasemo, B., Larsson, K., Lundström, I., McQueen, D. H., & Skalak, R. (1983) · Annals of Biomedical Engineering · doi:10.1007/bf02363944 · Cited by 436
Biomimetic apatite coatings on micro-arc oxidized titania
Song, W.-H., Jun, Y.-K., Han, Y., & Hong, S.-H. (2004) · Biomaterials · doi:10.1016/j.biomaterials.2003.09.103 · Cited by 407
Bonelike Hydroxyapatite Induction by a Gel‐Derived Titania on a Titanium Substrate
Li, P., Kangasniemi, I., de Groot, K., & Kokubo, T. (1994) · Journal of the American Ceramic Society · doi:10.1111/j.1151-2916.1994.tb05407.x · Cited by 344
A study on the mechanism of protein adsorption to TiO2
Ellingsen, J. E. (1991) · Biomaterials · doi:10.1016/0142-9612(91)90057-h · Cited by 335
Taveira, L. V., Macák, J. M., Tsuchiya, H., Dick, L. F. P., & Schmuki, P. (2005) · Journal of The Electrochemical Society · doi:10.1149/1.2008980 · Cited by 304
Self-citationWeng, J. (1997) · Biomaterials · doi:10.1016/s0142-9612(97)00022-7 · Cited by 266
Self-organized porous WO3 formed in NaF electrolytes
Tsuchiya, H., Macak, J. M., Sieber, I., Taveira, L., Ghicov, A., Sirotna, K., & Schmuki, P. (2005) · Electrochemistry Communications · doi:10.1016/j.elecom.2005.01.003 · Cited by 252
Self-citationSelf-organized high aspect ratio porous hafnium oxide prepared by electrochemical anodization
Tsuchiya, H., & Schmuki, P. (2005) · Electrochemistry Communications · doi:10.1016/j.elecom.2004.11.004 · Cited by 239
Self-citationApatite formation on TiO2 in simulated body fluid
Kasuga, T., Kondo, H., & Nogami, M. (2002) · Journal of Crystal Growth · doi:10.1016/s0022-0248(01)01782-1 · Cited by 202
Quasi-biological apatite film induced by titanium in a simulated body fluid
Li, P., & Ducheyne, P. (1998) · Journal of Biomedical Materials Research · doi:10.1002/(sici)1097-4636(19980905)41:3<341::aid-jbm1>3.0.co;2-c · Cited by 154
Cited by
TiO2 Nanotubes: Synthesis and Applications
Roy, P., Berger, S., & Schmuki, P. (2011) · Angewandte Chemie International Edition · doi:10.1002/anie.201001374 · Cited by 3,134
Self-citationTiO2 nanotubes: Self-organized electrochemical formation, properties and applications
Macak, J. M., Tsuchiya, H., Ghicov, A., Yasuda, K., Hahn, R., Bauer, S., & Schmuki, P. (2007) · Current Opinion in Solid State and Materials Science · doi:10.1016/j.cossms.2007.08.004 · Cited by 1,415
Self-citationOne-Dimensional Titanium Dioxide Nanomaterials: Nanotubes
Lee, K., Mazare, A., & Schmuki, P. (2014) · Chemical Reviews · doi:10.1021/cr500061m · Cited by 1,185
Self-citationGhicov, A., & Schmuki, P. (2009) · Chemical Communications · doi:10.1039/b822726h · Cited by 867
Self-citationSelf‐Organized TiO2 Nanotube Layers as Highly Efficient Photocatalysts
Macak, J. M., Zlamal, M., Krysa, J., & Schmuki, P. (2007) · Small · doi:10.1002/smll.200600426 · Cited by 815
Self-citation
Metadata
- Authors
- Tsuchiya, H., Macak, J. M., Müller, L., Kunze, J., Müller, F., Greil, P., Virtanen, S., & Schmuki, P.
- Venue
- Journal of Biomedical Materials Research Part A
- Publisher
- Wiley
- Published
- 2006-02-17
- Volume
- 77A
- Issue
- 3
- Pages
- 534-541
- ISSN
- 1549-3296 (ISSN-L)
- 1552-4965
- OpenAlex
- W1974950593
- Cited by
- 291
- References
- 23
- FWCI
- 15.11
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.