CoChat

iNOS‐mediated generation of reactive oxygen and nitrogen species by biomaterial‐adherent neutrophils

Patel, Jasmine D., Krupka, Tianyi, Anderson, James M. · 2007 · Journal of Biomedical Materials Research Part A
Cited by 53

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Abstract

Infection due to implanted cardiovascular biomaterials is a serious complication initiated by bacterial adhesion to the surface of the implant. The release of reactive oxygen species by neutrophils, particularly superoxide anion, is a well‐known bactericidal mechanism. Additionally, nitric oxide (NO) has also been identified as an important cytotoxic mediator in acute and chronic inflammatory responses with enhanced NO production by upregulation of inducible nitric oxide synthase (iNOS). The interaction of NO and superoxide anion will result in the formation of peroxynitrite (OONO−), a potent cytotoxic oxidant. In this study, we have shown that biomaterial‐induced neutrophil activation does not cause upregulation of iNOS and activation of iNOS‐mediated pathways. However, NO and O production does occur over time upon adhesion to a biomaterial and is modulated by biomaterial surface chemistry. With no stimulus, the polyethylene oxide‐modified polyurethane induced greater neutrophil activation than did the control as indicated by the increased production of NO and O over time. Adherent‐stimulated neutrophils generally produced lower amounts of NO over time in comparison with unstimulated cells. Furthermore, there is no evidence of peroxynitrite activity in unstimulated neutrophils adherent to the Elasthane 80A. However, upon stimulation with adherent Staphylococcus epidermidis, peroxynitrite formation did occur. Our results suggest that bactericidal mechanisms in neutrophils involving NO generation (NOS pathway) are further compromised than O producing pathways (NADPH oxidase) upon exposure to biomaterials, resulting in a diminished microbial killing capacity, which can increase the probability of device‐centered infections. © 2006 Wiley Periodicals, Inc. J Biomed Mater Res, 2007

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/jbm.a.30907

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

Metadata

Authors
Patel, J. D., Krupka, T., & Anderson, J. M.
Venue
Journal of Biomedical Materials Research Part A
Publisher
Wiley
Published
2006-12-13
Volume
80A
Issue
2
Pages
381-390
ISSN
  • 1549-3296 (ISSN-L)
  • 1552-4965
OpenAlex
W2152667707
Cited by
53
References
4
FWCI
0.34
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.