Cited by 25biodegradable polymer synthesis and propertiesPolymer Surface Interaction StudiesCoronary Interventions and Diagnostics

Cytocompatibility Evaluation of a Novel Series of PEG-Functionalized Lactide-Caprolactone Copolymer Biomaterials for Cardiovascular Applications

Open access
Pacharra, Sandra, McMahon, Seán, Duffy, Patrick, Basnett, Pooja, Yu, Wenfa, Seisel, Sabine, Stervbo, Ulrik, Babel, Nina +4 more·2020·Frontiers in Bioengineering and Biotechnology

Abstract

Although the use of bioresorbable materials in stent production is thought to improve long-term safety compared to their durable counterparts, a recent FDA report on the two-year follow-up of the first FDA-approved bioresorbable vascular stent showed an increased occurrence of major adverse cardiac events and thrombosis in comparison to the metallic control. In order to overcome the issues of first generation bioresorbable polymers, a series of polyethylene glycol-functionalized poly-L-lactide-co-ɛ-caprolactone copolymers with varying lactide-to-caprolactone content is developed using a novel one-step PEG-functionalization and copolymerization strategy. This approach represents a new facile way towards surface enhancement for cellular interaction, which is shown by screening these materials regarding their cyto- and hemocompatibility in terms of cytotoxicity, hemolysis, platelet adhesion, leucocyte activation and endothelial cell adhesion. By varying the lactide-to-caprolactone polymer composition, it is possible to gradually affect endothelial and platelet adhesion which allows fine-tuning of the biological response based on polymer chemistry. All polymers developed were non-cytotoxic, had acceptable leucocyte activation levels and presented non-hemolytic (< 2% hemolysis rate) behavior except for PLCL-PEG 55:45 which presented hemolysis rate of 2.5%±0.5. Water contact angles were reduced in the polymers containing PEG functionalization (PLLA-PEG: 69.8°±2.3, PCL-PEG: 61.2°±7.5) versus those without (PLLA: 79.5°±3.2, PCL: 76.4°±10.2) while the materials PCL-PEG550, PLCL-PEG550 90:10 and PLCL-PEG550 70:30 demonstrated best endothelial cell adhesion. PLLA-PEG550 and PLCL-PEG550 70:30 presented as best candidates for cardiovascular implant use from a cytocompatibility perspective across the spectrum of testing completed. Altogether, these polymers are excellent innovative materials suited for an application in stent manufacture due to the ease in translation of this one-step synthesis strategy to device production and their excellent in vitro cyto- and hemocompatibility.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.3389/fbioe.2020.00991

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • PEG-functionalized lactide-caprolactone copolymers demonstrated improved endothelial cytocompatibility and hemocompatibility in vitro.

    “For example, PEG-functionalized lactide–caprolactone copolymers demonstrated improved endothelial cytocompatibility and hemocompatibility in vitro [199].”

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Cites

Flagged first, then by citations

Research works printed but not linked: 54

  1. Alam S. R. Newby D. E. Henriksen P. A. (2012). Role of the endogenous elastase inhibitor, elafin, in cardiovascular injury: from epithelium to endothelium. Biochem. Pharmaco. 83 695– 704. 10.1016/j.bcp.2011.11.003 22100985 · DOI
  2. Al-Dehneh A. Virk H. Alkhouri Y. Hamdan A. Bikkina M. (2010). Drug-eluting stent thrombosis 1659 days after stent deployment: case report and literature review. Texas Heart Inst. J. 37 343– 346.s PMC2879219 20548819
  3. Auras R. Harte B. Selke S. (2004). An overview of polylactides as packaging materials. Macromol. Biosci. 4 835– 864. 10.1002/mabi.200400043 15468294 · DOI · Paper page
  4. Beuth Publishing (2009). “ International organization for standardization, ISO 10993-5,” in Biological Evaluation of Medical Devices - Part 5: Tests for in Vitro Cytotoxicity, (Berlin: Beuth Publishing DIN), 10.31030/1499596 · DOI
  5. Beuth Publishing (2017). “ International organization for standardization, ISO 10993-4,” in Biological Evaluation of Medical Devices - Part 4: Selection of Tests for Interactions With Blood, (Berlin: Beuth Publishing DIN), 10.31030/2597308 · DOI
  6. Blok S. L. J. Engels G. E. Van Oeveren W. (2016). In vitro hemocompatibility testing: the importance of fresh blood. Biointerphases 11 29802– 29801. 10.1116/1.4941850 26872581 · DOI
  7. Chen J. Cao J. Wang J. Maitz M. F. Guo L. Zhao Y. (2011). Biofunctionalization of titanium with PEG and anti-CD34 for hemocompatibility and stimulated endothelialization. J. Colloid Interface Sci. 368 636– 647. 10.1016/j.jcis.2011.11.039 22172691 · DOI
  8. Chuang T.-W. Masters K. S. (2009). Regulation of polyurethane hemocompatibility and endothelialization by tethered hyaluronic acid oligosaccharides. Biomaterials 30 5341– 5351. 10.1016/j.biomaterials.2009.06.029 19577800 · DOI
  9. Collet C. De Winter R. J. Onuma Y. Serruys P. W. (2016). The Absorb bioresorbable vascular scaffold for the treatment of coronary artery disease. Expert Opin. Drug Deli. 13 1489– 1499. 10.1080/17425247.2016.1227788 27550021 · DOI
  10. de Mel A. Jell G. Stevens M. M. Seifalian A. M. (2008). Biofunctionalization of biomaterials for accelerated in situ endothelialization: a review. Biomacromolecules 9 2969– 2979. 10.1021/bm800681k 18831592 · DOI
  11. Foin N. Lee R. Mattesini A. Caiazzo G. Fabris E. Kilic D. (2016). Bioabsorbable vascular scaffold overexpansion: insights from in vitro post-expansion experiments. EuroIntervention 11 1389– 1399. 10.4244/EIJY15M07_02 26151954 · DOI
  12. Galley H.-F. Webster N. R. (2004). Physiology of the endothelium. Br. J. Anaesthesia 93 105– 113. 10.1093/bja/aeh163 15121728 · DOI
  13. Garg S. Serruys P. W. (2010). Coronary Stents – Current status. J. Am. Coll. Cardiol. 56(Suppl.), S1– S42. 20797502
  14. Huang Y. Ng H. C. A. Ng X. W. Subbu V. (2014). Drug-eluting biostable and erodible stents. J. Control. Release 193 188– 201. 10.1016/j.jconrel.2014.05.011 24845127 · DOI
  15. Inthanon K. Daranarong D. Techaikool P. Punyodom W. Khaniyao V. Bernstein A. M. (2016). Biocompatibility assessment of PLCL-sericin copolymer membranes using Wharton’s Jelly mesenchymal stem cells. Stem Cells Internat. 2016 1– 16. 10.1155/2016/5309484 26839562 PMC4709783 · DOI
  16. Iqbal J. Gunn J. Serruys P. W. (2013). Coronary stents: historical development, current status and future directions. Br. Med. Bull. 106 193– 211. 10.1093/bmb/ldt009 23532779 · DOI
  17. Jeong S. I. Kim B.-S. Kang S. W. Kwon J. H. Lee Y. M. Kim S. H. (2004). In vivo biocompatibilty and degradation behavior of elastic poly(l-lactide-co-ε-caprolactone) scaffolds. Biomaterials 25 5939– 5946. 10.1016/j.biomaterials.2004.01.057 15183608 · DOI
  18. Khamis H. Shokry K. Ramzy A. Samir A. (2014). Bioresorbable vascular scaffold (ABSORB BVS);first report in egyptian patients with 6 month angiographic/IVUS follow up. Egyptian Heart J. 66 227– 232. 10.1016/j.ehj.2013.09.005 · DOI
  19. Khan W. Farah S. Domb A. J. (2012). Drug eluting stents: developments and current status. J. Control. Release 161 703– 712. 10.1016/j.jconrel.2012.02.010 22366546 · DOI
  20. Kim J. H. Noh H. Kang J. H. Lee B. S. Choi J. Park K. (2011). Characteristics of PLLA films blended with PEG block copolymers as additives for biodegradable polymer stents. Biomed. Eng. Lett. 1 42– 48. 10.1007/s13534-011-0004-0 · DOI
  21. Kingshott P. Griesser H. J. (1999). Surfaces that resist bioadhesion. Cur. Opin. Solid State Mater. Sci. 4 403– 412. 10.1016/s1359-0286(99)00018-2 · DOI
  22. Ko T.-M. Jui-Che L. Cooper S. L. (1993). Surface characterization and platelet adhesion studies of plasma-sulphonated polyethylene. Biomaterials 14 657– 664. 10.1016/0142-9612(93)90064-9 8399962 · DOI
  23. Lasprilla A. J. R. Martinez G. A. R. Lunelli B. H. Jardini A. L. Filho R. M. (2012). Poly-lactic acid synthesis for application in biomedical devices - a review. Biotechnol. Adv. 30 321– 328. 10.1016/j.biotechadv.2011.06.019 21756992 · DOI · Paper page
  24. Lieb E. Tessmar J. Hacker M. Fischbach C. Rose D. Blunk T. (2003). Poly(D,L-lactic acid)-poly(ethylene glycol)-monomethyl ether diblock copolymers control adhesion and osteoblastic differentiation of marrow stromal cells. Tissue Eng. 9 71– 84. 10.1089/107632703762687555 12625956 · DOI
  25. Lim J. I. Yu B. Lee Y. K. (2008). Fabrication of collagen hybridized elastic PLCL for tissue engineering. Biotech. Lett. 30 2085– 2090. 10.1007/s10529-008-9808-0 18661107 · DOI
  26. McMahon S. Bertollo N. O’ Cearbhaill E. D. Salber J. Pierucci L. Duffy P. (2018). Bio-resorbable polymer stents: a review of material progress and prospects. Prog. Polym. Sci. 83 79– 96. 10.1016/j.progpolymsci.2018.05.002 · DOI · Paper page
  27. McMahon S. Kennedy R. Duffy P. Vasquez J. M. Wall J. G. Tai H. (2016). Poly(ethylene glycol)-based hyperbranched polymer from RAFT and Its application as a silver-sulfadiazine-loaded antibacterial hydrogel in wound care. ACS Appl. Mater. Interfaces 8 26648– 26656. 10.1021/acsami.6b11371 27636330 · DOI
  28. Melchiorri A. J. Hibino N. Fisher J. P. (2013). Strategies and techniques to enhance the in situ endothelialization of small-diameter biodegradable polymeric vascular grafts. Tissue Eng. Part B Rev. 19 292– 307. 10.1089/ten.TEB.2012.0577 23252992 PMC3690089 · DOI
  29. Meraj P. M. Jauhar R. Singh A. (2015). Bare metal stents versus drug eluting stents: where do we stand in 2015? Curr. Treat. Opt. Cardiovasc. Med. 17 39– 49. 10.1007/s11936-015-0393-y 26154294 · DOI
  30. Neuss S. Apel C. Buttler P. Denecke B. Dhanasingh A. Ding X. (2008). Assessment of stem cell/biomaterial combinations for stem cell-based tissue engineering. Biomaterials 29 302– 313. 10.1016/j.biomaterials.2007.09.022 17935776 · DOI
  31. Noble W. S. (2009). How does multiple testing correction work? Nat. Biotechnol. 27 1135– 1137. 10.1038/nbt1209-1135 20010596 PMC2907892 · DOI · Paper page
  32. Noel S. Hachem A. Merhi Y. De Crescenzo G. (2015). Development of a polyester coating combining antithrombogenic and cell adhesive properties: influence of sequence and surface density of adhesion peptides. Biomacromolecules 16 1682– 1694. 10.1021/acs.biomac.5b00219 25877934 · DOI
  33. Oliveira J. E. Mattoso L. H. C. Orts W. J. Medeiros E. S. (2013). Structural and morphological characterization of micro and nanofibers produced by electrospinning and solution blow spinning: a comparative study. Adva. Mater. Sci. Eng. 2013 1– 14. 10.1155/2013/409572 · DOI · Paper page
  34. Ormiston J. A. Serruys P. W. (2009). Bioabsorbable coronary stents. Circ. Cardiovasc. Interv. 2 255– 260. 10.1161/circinterventions.109.859173 20031723 · DOI
  35. Pacharra S. Ortiz R. McMahon S. Wang W. Viebahn R. Salber J. (2019). Surface patterning of a novel PEG-functionalized poly-l-lactide polymer to improve its biocompatibility: applications to bioresorbable vascular stents. J. Biomed. Mater. Res. B Appl. Biomater. 107 624– 634. 10.1002/jbm.b.34155 30091510 PMC6585964 · DOI · Paper page
  36. Parnham M. J. Wetzig H. (1993). Toxicity screening of liposomes. Chem. Phys. Lipids 64 263– 274. 10.1016/0009-3084(93)90070-j 8242838 · DOI
  37. Patel J. D. Krupka T. Anderson J. M. (2006). iNOS-mediated generation of reactive oxygen and nitrogen species by biomaterial-adherent neutrophils. J. Biomed. Mater Res. Part A 80 381– 390. 10.1002/jbm.a.30907 17001645 · DOI
  38. Ren X. Feng Y. Guo J. Wang H. Li Q. Yang J. (2015). Surface modification and endothelialization of biomaterials as potential scaffolds for vascular tissue engineering applications. Chem. Soc. Rev. 44 5680– 5742. 10.1039/c4cs00483c 26023741 · DOI · Paper page
  39. Schrader B. (1995). Infrared and Raman Spectroscopy: Methods and Applications. Weinheim: Wiley-VCH Verlag GmbH.
  40. Shin H.-S. Park K. Kim J. H. Kim J.-J. Han D. K. Moon M.-W. (2009). Biocompatible PEG Grafting on DLC-coated nitinol alloy for vascular stents. J. Bioact. Comp. Polym. 24 316– 328. 10.1177/0883911509104273 · DOI
  41. Sperling C. Fischer M. Maitz M. F. Werner C. (2009). Blood coagulation on biomaterials requires the combination of distinct activation processes. Biomaterials 30 4447– 4456. 10.1016/j.biomaterials.2009.05.044 19535136 · DOI
  42. Tan J. Shen H. Carter K. L. Saltzman W. M. (2000). Controlling human polymorphonuclear leukocytes motility using microfabrication technology. J. Biomed. Mater. Res. 51 694– 702. 10.1002/1097-4636(20000915)51:4<694::aid-jbm18>3.0.co;2-n 10880118 · DOI
  43. Tenekecioglu E. Farooq V. Bourantas C. V. Silva R. C. Onuma Y. Yilmaz M. (2016). Bioresorbable scaffolds: a new paradigm in percutaneous coronary intervention. BMC Cardiovasc. Dis. 16: 38. 10.1186/s12872-016-0207-5 26868826 PMC4751731 · DOI
  44. Ugartemendia J. M. Munoz M. E. Santamaria A. Sarasua J. R. (2015). Supramolecular structure, phase behaviorand thermo-rheological properties of a poly(L-lactide-co-ε-caprolactone) statistical copolymer. J. Mech. Behav. Biomed. Mater. 48 153– 163. 10.1016/j.jmbbm.2015.04.007 25933171 · DOI
  45. Van Oeveren W. (2013). Obstacles in haemocompatibility testing. Scientifica 2013 1– 14. 10.1155/2013/392584 24278774 PMC3820147 · DOI
  46. Vasilev K. Poh Z. Kant K. Chan J. Michelmore A. Losic D. (2010). Tailoring the surface functionalities of titania nanotube arrays. Biomaterials 31 532– 540. 10.1016/j.biomaterials.2009.09.074 19819014 · DOI
  47. Verheye S. Ormiston J. A. Stewart J. Webster M. Sanidas E. Costa R. (2014). A next-generation bioresorbable coronary scaffold system: from bench to first clinical evaluation: 6- and 12-month clinical and multimodality imaging results. JACC Cardiovasc. Interv. 7 89– 99. 10.1016/j.jcin.2013.07.007 24139932 · DOI
  48. Waksman R. (2006). Biodegradable stents: they do their job and disappear. J. Invasive Cardiol. 18 70– 74. 16446520
  49. Wang J. He Y. Maitz M. F. Collins B. Xiong K. Guo L. (2013). A surface-eroding poly(1,3-trimethylene carbonate) coating for fully biodegradable magnesium-based stent applications: toward better biofunction, biodegradation and biocompatibility. Acta Biomate. 9 8678– 8689. 10.1016/j.actbio.2013.02.041 23467041 · DOI
  50. Wang W. Xiong W. Zhu Y. Xu H. Yang X. (2010). Protective effect of PEGylation against poly(amidoamine) dendrimer-induced hemolysis of human red blood cells. J. Biomed. Mater. Res. B Appl. Biomater. 93 59– 64. 10.1002/jbm.b.31558 20186802 · DOI
  51. Webster R. Didier E. Harris P. Siegel N. Stadler J. Tilbury L. (2007). PEGylated proteins: evaluation of their safety in the absence of definitive metabolism studies. Drug Metab. Disposit. 35 9– 16. 10.1124/dmd.106.012419 17020954 · DOI · Paper page
  52. Williams D. F. (2008). On the mechanisms of biocompatibility. Biomaterials 29 2941– 2953. 10.1016/j.biomaterials.2008.04.023 18440630 · DOI · Paper page
  53. Wu Y. Wang W. Chen Y. Huang K. Shuai X. Chen Q. (2010). The investigation of polymer-siRNA nanoparticle for gene therapy of gastric cancer in vitro. Int. J. Nanomed. 5 129– 136. 10.2147/IJN.S8503 20309399 PMC2841491 · DOI
  54. Zhang K. Liu T. Li J.-A. Chen J.-Y. Wang J. Huang N. (2014). Surface modification of implanted cardiovascular metal stents: from antithrombosis and antirestenosis to endothelialization. J. Biomed. Mater. Res. Part A 102 588– 609. 10.1002/jbm.a.34714 23520056 · DOI

Cited by

Sorted by citations

Authors
Pacharra, S., McMahon, S., Duffy, P., Basnett, P., Yu, W., Seisel, S., Stervbo, U., Babel, N., Roy, I., Viebahn, R., Wang, W., & Salber, J.
Affiliations
  • Ruhr University Bochum (DE)
  • University of Westminster (GB)
  • University Hospitals of the Ruhr-University of Bochum (DE)
  • University of Sheffield (GB)
  • Universitätsklinikum Knappschaftskrankenhaus Bochum (DE)
  • University College Dublin (IE)
Corresponding author
Salber, Jochen
Venue
Frontiers in Bioengineering and Biotechnology
Published
2020-08-13
Volume
8
Pages
991-991
ISSN
2296-4185 (ISSN-L)
OpenAlex
W3049743017
Cited by
25
References
2
Citations by year
2026: 8 · 2025: 7 · 2024: 5 · 2023: 3 · 2021: 2
FWCI
0.33
Type
journal article
Language
en
Open access
Locations
  • Frontiers in Bioengineering and Biotechnology (publishedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • White Rose Research Online (University of Leeds, The University of Sheffield, University of York) (acceptedVersion)
  • WestminsterResearch (University of Westminster) (acceptedVersion, cc-by)
  • Dokumentenrepositorium der RUB (Ruhr University Bochum) (submittedVersion, cc-by)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
Funders
  • Irish Research Council
  • Seventh Framework Programme
Topics
  • Physical Sciences › Materials Science › Biomaterials › biodegradable polymer synthesis and properties
  • Physical Sciences › Materials Science › Surfaces, Coatings and Films › Polymer Surface Interaction Studies
  • Health Sciences › Medicine › Surgery › Coronary Interventions and Diagnostics
Keywords
polyethylene glycol functionalization, cytocompatibility, hemocompatibility, endothelial cell adhesion, platelet adhesion, leukocyte activation, hemolysis, water contact angle, thrombosis

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review