Drug release from pH‐responsive thermogelling pentablock copolymers
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
A novel pH‐dependent injectable sustained delivery system was developed by utilizing a cationic pentablock copolymer that exhibits a thermoreversible sol‐gel transition. Aqueous solutions of the pentablock copolymer, consisting of poly(2‐diethylaminoethyl‐methyl methacrylate)‐poly(ethylene oxide)‐poly(propylene oxide)‐poly(ethylene oxide)‐poly(2‐diethylaminoethyl‐methyl methacrylate) (PDEAEM 25‐PEO 100‐PPO 65‐PEO 100‐PDEAEM 25) exhibit temperature and pH dependent micellization due to the lower critical solution temperature of the PPO blocks and the polyelectrolyte character of the PDEAEM blocks, respectively. Aqueous solutions of the copolymers above 12 wt % are free flowing liquids at room temperature and form elastic physical hydrogels reversibly above 37°C. Hydrophobic probe absorbance studies indicate that pentablock copolymer micelles increase the solubility of sparingly soluble drugs. Solutions of the pentablock copolymer that form gels at body temperature exhibit sustained zero‐order release in in vitro experiments. The release rates of model drugs and proteins were significantly influenced by the pH of the release media, thereby making these polymers ideal candidates for modulated drug delivery. © 2006 Wiley Periodicals, Inc. J Biomed Mater Res 2007
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Thermosensitive sol-gel reversible hydrogels
Jeong, B., Kim, S. W., & Bae, Y. H. (2002) · Advanced Drug Delivery Reviews · doi:10.1016/s0169-409x(01)00242-3 · Cited by 1,478
Kabanov, A. V., Nazarova, I. R., Astafieva, I. V., Batrakova, E. V., Alakhov, V. Y., Yaroslavov, A. A., & Kabanov, V. A. (1995) · Macromolecules · doi:10.1021/ma00111a026 · Cited by 459
Cited by
Hydrogels in drug delivery: Progress and challenges
Hoare, T. R., & Kohane, D. S. (2008) · Polymer · doi:10.1016/j.polymer.2008.01.027 · Cited by 3,776
pH-Sensitive nano-systems for drug delivery in cancer therapy
Liu, J., Huang, Y., Kumar, A., Tan, A., Jin, S., Mozhi, A., & Liang, X.-J. (2014) · Biotechnology Advances · doi:10.1016/j.biotechadv.2013.11.009 · Cited by 1,121
In situ gelling stimuli-sensitive block copolymer hydrogels for drug delivery
He, C., Kim, S. W., & Lee, D. S. (2008) · Journal of Controlled Release · doi:10.1016/j.jconrel.2008.01.005 · Cited by 867
Smart drug delivery systems: from fundamentals to the clinic
Alvarez-Lorenzo, C., & Concheiro, A. (2014) · Chem. Commun. · doi:10.1039/c4cc01429d · Cited by 415
Nanomicellar formulations for sustained drug delivery: strategies and underlying principles
Trivedi, R., & Kompella, U. B. (2010) · Nanomedicine · doi:10.2217/nnm.10.10 · Cited by 358
Metadata
- Authors
- Determan, M. D., Cox, J. P., & Mallapragada, S. K.
- Venue
- Journal of Biomedical Materials Research Part A
- Publisher
- Wiley
- Published
- 2006-11-21
- Volume
- 81A
- Issue
- 2
- Pages
- 326-333
- ISSN
- 1549-3296 (ISSN-L)
- 1552-4965
- OpenAlex
- W2055284325
- Cited by
- 75
- References
- 2
- FWCI
- 2.20
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.