The DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.
Biodegradable magnesium scaffolds: Part 1: Appropriate inflammatory response
Abstract
Current tissue engineering strategies focus on the replacement of pathologically altered tissues by the transplantation of cells in combination with supportive biocompatible scaffolds. Scaffolds for tissue engineering strategies in musculoskeletal research require an appropriate mechanical stability. In recent studies, considerable attention has thus been given to magnesium alloys as biodegradable implants. The aim of this study was to characterize the biocompatibility of magnesium scaffolds by the inflammatory host response. Open porous scaffolds made of the magnesium alloy AZ91D were implanted into the distal femur condyle of rabbits and were compared to autologous bone, which was transplanted into the contralateral condyle in a 3 and 6 months follow‐up group. After 3 months, magnesium scaffolds were already largely degraded and most of the original magnesium alloy has disappeared. Concomitantly, a fibrous capsule enclosed the operation site. Histological analysis revealed that the magnesium scaffolds caused no significant harm to their neighboring tissues. This study shows that even fast degrading magnesium scaffolds show a good biocompatibility and react in vivo with an appropriate inflammatory host response. Magnesium alloy based implants are therefore a very promising approach in the development of mechanically suitable and open porous scaffolds for the replacement of subchondral bone in cartilage tissue engineering. © 2007 Wiley Periodicals, Inc. J Biomed Mater Res 2007
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Atlas of Electrochemical Equilibria in Aqueous Solutions
Pourbaix, M. (1974) · doi:10.5006/37502 · Cited by 8,026
Histochemistry: Theoretical and Applied
(1953) · Journal of the American Medical Association · doi:10.1001/jama.1953.02940280072039 · Cited by 7,021
Magnesium and its alloys as orthopedic biomaterials: A review
Staiger, M. P., Pietak, A. M., Huadmai, J., & Dias, G. (2006) · Biomaterials · doi:10.1016/j.biomaterials.2005.10.003 · Cited by 4,452
Porous scaffold design for tissue engineering
Hollister, S. J. (2005) · Nature Materials · doi:10.1038/nmat1421 · Cited by 3,969
Biodegradation and biocompatibility of PLA and PLGA microspheres
Anderson, J. M., & Shive, M. S. (1997) · Advanced Drug Delivery Reviews · doi:10.1016/s0169-409x(97)00048-3 · Cited by 2,617
In vivo corrosion of four magnesium alloys and the associated bone response
Witte, F., Kaese, V., Haferkamp, H., Switzer, E., Meyer-Lindenberg, A., Wirth, C. J., & Windhagen, H. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2004.09.049 · Cited by 2,395
Self-citationRomeis, B. (1948) · De Gruyter eBooks · doi:10.1515/9783486777031 · Cited by 2,339
Hunziker, E. B. (2002) · Osteoarthritis and Cartilage · doi:10.1053/joca.2002.0801 · Cited by 1,975
In vitro and in vivo corrosion measurements of magnesium alloys
Witte, F., Fischer, J., Nellesen, J., Crostack, H.-A., Kaese, V., Pisch, A., Beckmann, F., & Windhagen, H. (2006) · Biomaterials · doi:10.1016/j.biomaterials.2005.07.037 · Cited by 1,386
Self-citationHistochemistry, Theoretical and Applied.
DIXON, K. C. (1972) · Europe PMC (PubMed Central) · Cited by 962
The effect of scaffold degradation rate on three-dimensional cell growth and angiogenesis
Sung, H.-J., Meredith, C., Johnson, C., & Galis, Z. S. (2004) · Biomaterials · doi:10.1016/j.biomaterials.2004.01.066 · Cited by 804
Merian, E. (1980) · Chemosphere · doi:10.1016/0045-6535(80)90105-8 · Cited by 623
Clinical biocompatibility of biodegradable orthopaedic implants for internal fixation: a review
Böstman, O., & Pihlajamäki, H. (2000) · Biomaterials · doi:10.1016/s0142-9612(00)00129-0 · Cited by 509
Adverse Tissue Reactions to Bioabsorbable Fixation Devices
B??stman, O. M., & Pihlajam??ki, H. K. (2000) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-200002000-00026 · Cited by 476
Osteolytic changes accompanying degradation of absorbable fracture fixation implants
Bostman, O. (1991) · The Journal of Bone and Joint Surgery. British volume · doi:10.1302/0301-620x.73b4.1649195 · Cited by 294
The Road to Bioabsorbable Stents: Reaching Clinical Reality?
Erne, P., Schier, M., & Resink, T. J. (2006) · CardioVascular and Interventional Radiology · doi:10.1007/s00270-004-0341-9 · Cited by 249
ABSORBABLE METAL IN BONE SURGERY: A FURTHER REPORT ON THE USE OF MAGNESIUM ALLOYS
McBRIDE, E. D. (1938) · Journal of the American Medical Association · doi:10.1001/jama.1938.02790530018007 · Cited by 231
Cellular metals and metal foaming technology
Banhart, J., Ashby, M. F., & Flech, N. A. (2001) · Cited by 167
Qiu, Y., Shahgaldi, B. F., Revell, W. J., & Heatley, F. W. (2003) · Osteoarthritis and Cartilage · doi:10.1016/s1063-4584(03)00164-x · Cited by 128
Scaffold-based bone engineering by using genetically modified cells
Hutmacher, D. W., & Garcı́a, A. J. (2005) · Gene · doi:10.1016/j.gene.2004.12.040 · Cited by 90
Scaffolds for liver tissue engineering
Hammond, J. S., Beckingham, I. J., & Shakesheff, K. M. (2005) · Expert Review of Medical Devices · doi:10.1586/17434440.3.1.21 · Cited by 49
Aluminon: its limited application as a reagent for the detection of aluminum species.
Clark, R., & Krueger, G. L. (1985) · Journal of Histochemistry & Cytochemistry · doi:10.1177/33.7.3891845 · Cited by 33
Suzuki, K., Kobayashi, N., Doi, T., Hijikata, T., Machida, I., & Namiki, H. (2003) · Cell Structure and Function · doi:10.1247/csf.28.243 · Cited by 9
Agrawal (1997) · doi:10.1002/(sici)1097-4636(199722)38:2<105::aid-jbm4>3.0.co;2-u
Cited by
Zheng, Y. F., Gu, X. N., & Witte, F. (2014) · Materials Science and Engineering: R: Reports · doi:10.1016/j.mser.2014.01.001 · Cited by 2,436
Self-citationDegradable biomaterials based on magnesium corrosion
Witte, F., Hort, N., Vogt, C., Cohen, S., Kainer, K. U., Willumeit, R., & Feyerabend, F. (2008) · Current Opinion in Solid State and Materials Science · doi:10.1016/j.cossms.2009.04.001 · Cited by 1,820
Self-citationThe development of binary Mg–Ca alloys for use as biodegradable materials within bone
Li, Z., Gu, X., Lou, S., & Zheng, Y. (2008) · Biomaterials · doi:10.1016/j.biomaterials.2007.12.021 · Cited by 1,593
Research on an Mg–Zn alloy as a degradable biomaterial
Zhang, S., Zhang, X., Zhao, C., Li, J., Song, Y., Xie, C., Tao, H., Zhang, Y., He, Y., Jiang, Y., et al. (2010) · Acta Biomaterialia · doi:10.1016/j.actbio.2009.06.028 · Cited by 1,336
Agarwal, S., Curtin, J., Duffy, B., & Jaiswal, S. (2016) · Materials Science and Engineering: C · doi:10.1016/j.msec.2016.06.020 · Cited by 955
Metadata
- Authors
- Witte, F., Ulrich, H., Rudert, M., & Willbold, E.
- Venue
- Journal of Biomedical Materials Research Part A
- Publisher
- Wiley
- Published
- 2007-03-27
- Volume
- 81A
- Issue
- 3
- Pages
- 748-756
- ISSN
- 1549-3296 (ISSN-L)
- 1552-4965
- OpenAlex
- W2163936468
- Cited by
- 409
- References
- 24
- FWCI
- 8.19
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.