Monocyte activation in response to polyethylene glycol hydrogels grafted with RGD and PHSRN separated by interpositional spacers of various lengths
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Polyethylene glycol (PEG) is often cited as a “stealth” polymer, capable of resisting both protein adsorption and cell adhesion. By extension, PEG would then be expected to limit the host response. Monocyte‐derived macrophages play an integral role in inflammation, and thus their response to a material can potentially dictate the overall host response to a biomaterial. In the present study, monocyte responses following interaction with a photopolymerized PEG hydrogel were compared with those from standard tissue culture polystyrene (TCPS). Additionally, the effect of the spacing between RGD and PHSRN, the corresponding synergy sequence on fibronectin (FN), was evaluated using peptides with differing spacer lengths grafted to the PEG hydrogel. Monocyte adherent density on the PEG‐only hydrogel was comparable with that of TCPS; however, the secretion of the proinflammatory molecules interleukin‐1β (IL‐1β), tumor necrosis factor‐α (TNF‐α), and granulocyte‐macrophage colony stimulating factor (GM‐CSF) increased dramatically following monocyte interaction with PEG‐only hydrogels as compared with TCPS. The matrix metalloproteinase‐2 (MMP‐2) concentration was similar for all surfaces, while both the matrix metalloproteinase‐9 (MMP‐9) and FN concentrations were above the range of the assay for all substrates. Cell density was higher on the PHSRNG 13 RGD grafted substrate as compared with PHSRNG 6 RGD, but neither sequence increased cell density versus RGD alone. Although protein concentration did sometimes vary with different peptides, this variation was minimal in comparison with the surface effects between TCPS and the PEG‐only hydrogel. This study explores the roles of PEG and FN‐derived peptides on monocyte activation. © 2007 Wiley Periodicals, Inc. J Biomed Mater Res 2007
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Biomaterials: Where We Have Been and Where We Are Going
Ratner, B. D., & Bryant, S. J. (2004) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.6.040803.140027 · Cited by 1,507
Biomaterials in Tissue Engineering
Hubbell, J. A. (1995) · Nature Biotechnology · doi:10.1038/nbt0695-565 · Cited by 1,060
Complement C3 participation in monocyte adhesion to different surfaces
McNally, A. K., & Anderson, J. M. (1994) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.91.21.10119 · Cited by 174
Cited by
Bone Tissue Engineering: Recent Advances and Challenges
Amini, A. R., Laurencin, C. T., & Nukavarapu, S. P. (2012) · Critical Reviews in Biomedical Engineering · doi:10.1615/critrevbiomedeng.v40.i5.10 · Cited by 2,336
Bioactive modification of poly (ethylene glycol) hydrogels for tissue engineering
Zhu, J. (2010) · Biomaterials · doi:10.1016/j.biomaterials.2010.02.044 · Cited by 1,457
Design properties of hydrogel tissue-engineering scaffolds
Zhu, J., & Marchant, R. E. (2011) · Expert Review of Medical Devices · doi:10.1586/erd.11.27 · Cited by 1,430
Franz, S., Rammelt, S., Scharnweber, D., & Simon, J. C. (2011) · Biomaterials · doi:10.1016/j.biomaterials.2011.05.078 · Cited by 1,391
Synthetic polymer scaffolds for tissue engineering
Place, E. S., George, J. H., Williams, C. K., & Stevens, M. M. (2009) · Chemical Society Reviews · doi:10.1039/b811392k · Cited by 815
Metadata
- Authors
- Schmidt, D. R., & Kao, W. J.
- Venue
- Journal of Biomedical Materials Research Part A
- Publisher
- Wiley
- Published
- 2007-05-14
- Volume
- 83A
- Issue
- 3
- Pages
- 617-625
- ISSN
- 1549-3296 (ISSN-L)
- 1552-4965
- OpenAlex
- W2044564750
- Cited by
- 56
- References
- 3
- FWCI
- 2.67
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.