The DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.
In vitro evaluation of electrospun nanofiber scaffolds for vascular graft application
Abstract
Blood vessels are diverse in size, mechanical and biochemical properties, cellular content, and ultrastructural organization depending on their location and specific function. Therefore, it is required to control the fabrication of vascular grafts for obtaining desirable characteristics of blood vessel substitutes. In this study we have fabricated various scaffolds using the electrospinning technique with blends of collagen, elastin, and several biodegradable polymers. Biocompatibility, dimensional stability in vitro and mechanical properties were evaluated. Materials were blended at a relative concentration by weight of 45% collagen, 15% elastin, and 40% synthetic polymer to mimic the ratio of collagen and elastin in native blood vessels. The fabricated scaffolds are composed of randomly oriented fibers with diameters ranging from 477 to 765 nm. The electrospun scaffolds are nontoxic, dimensionally stable in an in vitro culture environment, easily fabricated, and possess controlled mechanical properties that simulate the ultrastructure of native blood vessels. The present study suggests that the introduction of synthetic biodegradable polymers enabled tailoring of mechanical properties of vascular substitutes and improving compliance matching for vascular tissue engineering. © 2007 Wiley Periodicals, Inc. J Biomed Mater Res, 2007
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Color test for detection of free terminal amino groups in the solid-phase synthesis of peptides
Kaiser, E., Colescott, R. L., Bossinger, C. D., & Cook, P. I. (1970) · Analytical Biochemistry · doi:10.1016/0003-2697(70)90146-6 · Cited by 3,516
Electrospinning of Collagen Nanofibers
Matthews, J. A., Wnek, G. E., Simpson, D. G., & Bowlin, G. L. (2002) · Biomacromolecules · doi:10.1021/bm015533u · Cited by 2,251
Functional Arteries Grown in Vitro
Niklason, L. E., Gao, J., Abbott, W. M., Hirschi, K. K., Houser, S., Marini, R., & Langer, R. (1999) · Science · doi:10.1126/science.284.5413.489 · Cited by 1,766
A completely biological tissue-engineered human blood vessel
L'heureux, N., Pâquet, S., Labbé, R., Germain, L., & Auger, F. A. (1998) · The FASEB Journal · doi:10.1096/fasebj.12.1.47 · Cited by 1,402
A Blood Vessel Model Constructed from Collagen and Cultured Vascular Cells
Weinberg, C. B., & Bell, E. (1986) · Science · doi:10.1126/science.2934816 · Cited by 1,240
Functional small-diameter neovessels created using endothelial progenitor cells expanded ex vivo
Kaushal, S., Amiel, G. E., Guleserian, K. J., Shapira, O. M., Perry, T., Sutherland, F. W., Rabkin, E., Moran, A. M., Schoen, F. J., Atala, A., et al. (2001) · Nature Medicine · doi:10.1038/nm0901-1035 · Cited by 841
Self-citationSmall intestinal submucosa as a large diameter vascular graft in the dog
Badylak, S. F., Lantz, G. C., Coffey, A., & Geddes, L. A. (1989) · Journal of Surgical Research · doi:10.1016/0022-4804(89)90050-4 · Cited by 613
Electrospinning collagen and elastin: preliminary vascular tissue engineering
Boland, E. (2004) · Frontiers in Bioscience · doi:10.2741/1313 · Cited by 537
Biomaterials in the development and future of vascular grafts
Xue, L., & Greisler, H. P. (2003) · Journal of Vascular Surgery · doi:10.1067/mva.2003.88 · Cited by 519
Engineered collagen–PEO nanofibers and fabrics
Huang, L., Nagapudi, K., P.Apkarian, R., & Chaikof, E. L. (2001) · Journal of Biomaterials Science, Polymer Edition · doi:10.1163/156856201753252516 · Cited by 501
Healing of Arterial Prostheses in Man
Berger, K., Sauvage, L. R., Rao, A. M., & Wood, S. J. (1972) · Annals of Surgery · doi:10.1097/00000658-197201000-00018 · Cited by 442
Controlled fabrication of a biological vascular substitute
Stitzel, J., Liu, J., Lee, S. J., Komura, M., Berry, J., Soker, S., Lim, G., Van Dyke, M., Czerw, R., Yoo, J. J., et al. (2006) · Biomaterials · doi:10.1016/j.biomaterials.2005.07.048 · Cited by 435
Self-citationDecellularized vein as a potential scaffold for vascular tissue engineering
Schaner, P. J., Martin, N. D., Tulenko, T. N., Shapiro, I. M., Tarola, N. A., Leichter, R. F., Carabasi, R. A., & DiMuzio, P. J. (2004) · Journal of Vascular Surgery · doi:10.1016/j.jvs.2004.03.033 · Cited by 339
Remodeling of an acellular collagen graft into a physiologically responsive neovessel
Huynh, T., Abraham, G., Murray, J., Brockbank, K., Hagen, P.-O., & Sullivan, S. (1999) · Nature Biotechnology · doi:10.1038/15062 · Cited by 330
Tissue engineering of vascular grafts
Ratcliffe, A. (2000) · Matrix Biology · doi:10.1016/s0945-053x(00)00080-9 · Cited by 290
Elastomeric nanofibers of styrene-butadiene-styrene triblock copolymer
Fong, H., & Reneker, D. H. (1999) · Journal of Polymer Science Part B: Polymer Physics · doi:10.1002/(sici)1099-0488(19991215)37:24<3488::aid-polb9>3.0.co;2-m · Cited by 280
Seifalian, A. M., Tiwari, A., Hamilton, G., & Salacinski, H. J. (2002) · Artificial Organs · doi:10.1046/j.1525-1594.2002.06841.x · Cited by 225
Long-term results of femorotibial bypass with vein or polytetrafluoroethylene
Sayers, R. D., Raptis, S., Berce, M., & Miller, J. H. (1998) · Journal of British Surgery · doi:10.1046/j.1365-2168.1998.00765.x · Cited by 194
Pariente, J.-L., Kim, B., & Atala, A. (2002) · The Journal of Urology · doi:10.1016/s0022-5347(05)65251-2 · Cited by 150
Self-citationStitzel, J. D., Pawlowski, K. J., Wnek, G. E., Simpson, D. G., & Bowlin, G. L. (2001) · Journal of Biomaterials Applications · doi:10.1106/u2uu-m9qh-y0bb-5gyl · Cited by 120
Self-citationFabrication and Biocompatibility of Collagen Sponge Reinforced with Poly(glycolic acid) Fiber
Hiraoka, Y., Kimura, Y., Ueda, H., & Tabata, Y. (2003) · Tissue Engineering · doi:10.1089/10763270360728017 · Cited by 119
Gumpenberger, T., Heitz, J., Bäuerle, D., Kahr, H., Graz, I. M., Romanin, C., Švorčík, V., & Leisch, F. (2003) · Biomaterials · doi:10.1016/s0142-9612(03)00460-5 · Cited by 92
Engineering conduits to resemble natural vascular tissue
Buján, J., García‐Honduvilla, N., & Bellón, J. M. (2004) · Biotechnology and Applied Biochemistry · doi:10.1042/ba20030111 · Cited by 37
Cited by
Electrospinning: Applications in drug delivery and tissue engineering
Sill, T. J., & von Recum, H. A. (2008) · Biomaterials · doi:10.1016/j.biomaterials.2008.01.011 · Cited by 3,289
Use of electrospinning technique for biomedical applications
Agarwal, S., Wendorff, J. H., & Greiner, A. (2008) · Polymer · doi:10.1016/j.polymer.2008.09.014 · Cited by 1,822
Nanotechnology and nanomaterials: Promises for improved tissue regeneration
Zhang, L., & Webster, T. J. (2009) · Nano Today · doi:10.1016/j.nantod.2008.10.014 · Cited by 1,143
Biomimetic electrospun nanofibrous structures for tissue engineering
Wang, X., Ding, B., & Li, B. (2013) · Materials Today · doi:10.1016/j.mattod.2013.06.005 · Cited by 779
Choi, J. S., Lee, S. J., Christ, G. J., Atala, A., & Yoo, J. J. (2008) · Biomaterials · doi:10.1016/j.biomaterials.2008.03.031 · Cited by 611
Self-citation
Metadata
- Authors
- Lee, S. J., Yoo, J. J., Lim, G. J., Atala, A., & Stitzel, J.
- Venue
- Journal of Biomedical Materials Research Part A
- Publisher
- Wiley
- Published
- 2007-06-21
- Volume
- 83A
- Issue
- 4
- Pages
- 999-1008
- ISSN
- 1549-3296 (ISSN-L)
- 1552-4965
- OpenAlex
- W2119249751
- Cited by
- 268
- References
- 23
- FWCI
- 9.16
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.