Effect of scaffold architecture and pore size on smooth muscle cell growth
The DOI matches its Crossref record.
Abstract
Tissue engineering has the potential to replace damaged tissues and organs. Diffusion limitation of cell growth in three‐dimensional (3D) scaffolds is a significant constraint in most tissue engineering applications. This study describes a scaffold architecture that improves mass transfer. Scaffolds with three different geometries of villi architecture (0.5, 1, 0.5; 0.5, 1, 1; 1, 1, 1 mm; villus diameter, height, intervillus spacing, respectively) were fabricated by indirect 3D printing technique. The ability of these scaffolds to support smooth muscle cell growth was investigated in vitro. Smooth muscle cells attached to the scaffolds uniformly after 1 day of culture, and the cell density in the scaffold with small villi feature (0.5 mm) was significantly higher as compared to that for the scaffold with large villi features (1 mm) after 14 days of culture. To evaluate the effect of scaffold pore size on cell growth, scaffolds with three different pore size ranges (50–100, 100–150, and 150–200 μm) were fabricated by the solvent casting and particulate leaching technique. Scaffold pore size did not significantly affect cell growth after 14 days of culture. Optimization in the architectural design of scaffolds provides an alternative method to improve diffusion limitation in the 3D constructs. © 2008 Wiley Periodicals, Inc. J Biomed Mater Res 2008
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Biomedical applications of biodegradable polymers
Ulery, B. D., Nair, L. S., & Laurencin, C. T. (2011) · Journal of Polymer Science Part B: Polymer Physics · doi:10.1002/polb.22259 · Cited by 2,206
Recent advances in 3D printing of biomaterials
Chia, H. N., & Wu, B. M. (2015) · Journal of Biological Engineering · doi:10.1186/s13036-015-0001-4 · Cited by 1,734
Self-citationRecent advances in biomaterials for 3D scaffolds: A review
Nikolova, M. P., & Chavali, M. S. (2019) · Bioactive Materials · doi:10.1016/j.bioactmat.2019.10.005 · Cited by 907
“For example, pores with 200–400 μm size were found to be effective for bone tissue formation [9], while 50–200 μm pores were suitable for smooth muscle cell growth [10].”
BackgroundScaffolds and cells for tissue regeneration: different scaffold pore sizes—different cell effects
Bružauskaitė, I., Bironaitė, D., Bagdonas, E., & Bernotienė, E. (2016) · Cytotechnology · doi:10.1007/s10616-015-9895-4 · Cited by 797
Bioactive polymeric scaffolds for tissue engineering
Stratton, S., Shelke, N. B., Hoshino, K., Rudraiah, S., & Kumbar, S. G. (2016) · Bioactive Materials · doi:10.1016/j.bioactmat.2016.11.001 · Cited by 469
Metadata
- Authors
- Lee, M., Wu, B. M., & Dunn, J. C. Y.
- Venue
- Journal of Biomedical Materials Research Part A
- Publisher
- Wiley
- Published
- 2008-02-06
- Volume
- 87A
- Issue
- 4
- Pages
- 1010-1016
- ISSN
- 1549-3296 (ISSN-L)
- 1552-4965
- OpenAlex
- W2021355758
- Cited by
- 141
- References
- 0
- FWCI
- 5.54
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Effect of scaffold architecture and pore size on smooth muscle cell growth. https://app.cochat.ai/papers/10.1002/jbm.a.31816
- The paper
- Lee, M., Wu, B. M., & Dunn, J. C. Y. (2008). Effect of scaffold architecture and pore size on smooth muscle cell growth. Journal of Biomedical Materials Research Part A. https://doi.org/10.1002/jbm.a.31816
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.