Assessment of the biocompatibility of photosensitive polyimide for implantable medical device use
Open accessThe DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
Polyimides have been widely used for biosensor encapsulation and more recently as substrates for neural implants. They have excellent thermal stability, high chemical resistance, and can be prepared as thin, flexible films. Photosensitive polyimides present similar physical properties to polyimides, and have the advantage that they can be photo‐lithographically patterned. However, to date little data on their biocompatibility has been reported. Two commercially available polyimides (PI) and one photo‐sensitive polyimide (PSPI) were evaluated in vitro using the ISO 10993 standard on biocompatibility. The materials were Dupont Kapton foil HN, HD Microsystem PI2611, and Fujifilm Durimide 7020 (PSPI). PI2611 and Durimide 7020 were spin‐coated on silicon wafers, cured at temperatures ranging from 150 to 450°C, and sterilized by autoclave. All materials were evaluated using a scanning electron microscope pre‐ and postcell culture. Cell viability was determined by an MTS assay. Their mechanical properties and stability during cell culture as a function of time and environment were investigated by nanoindentation. The MTS results show that PSPI is noncytotoxic compared with the negative control of polyethylene and the conventional PIs tested. Fibroblast adhesion, morphology, and spreading were good and better on the PSPI substrate than on the PI2611. Schwann cell appearance was similar on each of the PIs and the PSPI tested. The results suggest that PSPIs may have potential use for biological microsystem and neuroprosthetic applications. © 2008 Wiley Periodicals, Inc. J Biomed Mater Res, 2009
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Response of brain tissue to chronically implanted neural electrodes
Polikov, V. S., Tresco, P. A., & Reichert, W. M. (2005) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2005.08.015 · Cited by 1,896
Campbell, P. K., Jones, K. E., Huber, R. J., Horch, K. W., & Normann, R. A. (1991) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.83588 · Cited by 881
Flexible polyimide-based intracortical electrode arrays with bioactive capability
Rousche, P. J., Pellinen, D. S., Pivin, D. P., Williams, J. C., Vetter, R. J., & Kipke, D. R. (2001) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.914800 · Cited by 644
Polyimide cuff electrodes for peripheral nerve stimulation
Rodri´guez, F. J., Ceballos, D., Schu¨ttler, M., Valero, A., Valderrama, E., Stieglitz, T., & Navarro, X. (2000) · Journal of Neuroscience Methods · doi:10.1016/s0165-0270(00)00192-8 · Cited by 207
Cited by
Abagnale, G., Steger, M., Nguyen, V. H., Hersch, N., Sechi, A., Joussen, S., Denecke, B., Merkel, R., Hoffmann, B., Dreser, A., et al. (2015) · Biomaterials · doi:10.1016/j.biomaterials.2015.05.030 · Cited by 386
In vitro evaluation of the long-term stability of polyimide as a material for neural implants
Rubehn, B., & Stieglitz, T. (2010) · Biomaterials · doi:10.1016/j.biomaterials.2010.01.053 · Cited by 242
The future of neuroscience: flexible and wireless implantable neural electronics
McGlynn, E., Nabaei, V., Ren, E., Galeote‐Checa, G., Das, R., Curia, G., & Heidari, H. (2021) · Advanced Science · doi:10.1002/advs.202002693 · Cited by 115
Long Micro-Channel Electrode Arrays: A Novel Type of Regenerative Peripheral Nerve Interface
Lacour, S. P., Fitzgerald, J. J., Lago, N., Tarte, E., McMahon, S., & Fawcett, J. (2009) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2009.2031241 · Cited by 75
Self-citationPolyimide micro-channel arrays for peripheral nerve regenerative implants
Lacour, S. P., Atta, R., FitzGerald, J. J., Blamire, M., Tarte, E., & Fawcett, J. (2008) · Sensors and Actuators A: Physical · doi:10.1016/j.sna.2008.05.031 · Cited by 56
Self-citation
Metadata
- Authors
- Sun, Y., Lacour, S. P., Brooks, R. A., Rushton, N., Fawcett, J., & Cameron, R. E.
- Venue
- Journal of Biomedical Materials Research Part A
- Publisher
- Wiley
- Published
- 2008-06-18
- Volume
- 90A
- Issue
- 3
- Pages
- 648-655
- ISSN
- 1549-3296 (ISSN-L)
- 1552-4965
- OpenAlex
- W2106987596
- Cited by
- 122
- References
- 4
- FWCI
- 2.07
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.