CoChat

The DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.

Long Micro-Channel Electrode Arrays: A Novel Type of Regenerative Peripheral Nerve Interface

Open access
Lacour, StÉphanie P., Fitzgerald, James J., Lago, Natalia, Tarte, Edward, McMahon, Stephen, Fawcett, James · 2009 · IEEE Transactions on Neural Systems and Rehabilitation Engineering

Abstract

We have demonstrated that micro-channel electrode arrays with 100 microm x 100 microm cross-section channels support axon regeneration well, and that micro-channels of similar calibre and up to 5 mm long can support axon regeneration and vascularisation. They may be microfabricated using silicon, silicone, or polyimide and thin metal films to form 3-D bundles of long micro-channels. Arrays of "mini-nerves," i.e., miniature nerve fascicles with their own blood vessels, successfully grew through implants 0.5-5 mm long. Furthermore, guiding the regenerating nerve fibres into the small insulating channels allows for a significant increase of the extracellular (recordable) amplitude of action potentials, which promises considerable improvement for in vivo electrophysiology.

Overview

Integrity signals

Registry

Crossref · 10.1109/tnsre.2009.2031241

Cites

15 of 15 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 15 references

Cited by

See all 83

Metadata

Authors
Lacour, S. P., Fitzgerald, J. J., Lago, N., Tarte, E., McMahon, S., & Fawcett, J.
Affiliations
  • University of Cambridge (GB)
  • King's College London (GB)
  • University of Birmingham (GB)
Venue
IEEE Transactions on Neural Systems and Rehabilitation Engineering
Published
2009-10
Volume
17
Issue
5
Pages
454-460
ISSN
  • 1534-4320 (ISSN-L)
  • 1558-0210
OpenAlex
W2139282950
Cited by
75
References
15
Citations by year
2026: 2 · 2025: 1 · 2024: 7 · 2023: 3 · 2022: 1 · 2021: 3 · 2020: 2 · 2019: 3 · 2018: 7 · 2017: 6 · 2016: 7 · 2015: 7 · 2014: 4 · 2013: 5 · 2012: 4
FWCI
2.35
Type
journal article
Language
en
Open access
Locations
  • IEEE Transactions on Neural Systems and Rehabilitation Engineering (publishedVersion)
  • PubMed (publishedVersion)
  • Infoscience (Ecole Polytechnique Fédérale de Lausanne) (submittedVersion)
  • Infoscience (Ecole Polytechnique Fédérale de Lausanne) (submittedVersion, cc-by-nc-nd)
  • Research Portal (King's College London) (submittedVersion)
  • University of Birmingham Research Portal (University of Birmingham) (submittedVersion)
Funders
Engineering and Physical Sciences Research Council (EP/C52330X/1, EP/H00727X/1)
Topics
  • Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
  • Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Nerve injury and regeneration
  • Health Sciences › Medicine › Surgery › Tissue Engineering and Regenerative Medicine
Keywords
peripheral nerve interfaces, axon regeneration, nerve guidance channels, silicon microchannels, action potential amplitude, in vivo electrophysiology, peripheral nerve stimulation
MeSH terms
Action Potentials, Animals, Electrodes, Implanted, Equipment Design, Male, Microelectrodes, Nerve Regeneration, Sensitivity and Specificity, Reproducibility of Results, Equipment Failure Analysis, Sciatic Neuropathy, Guided Tissue Regeneration, Rats

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Long Micro-Channel Electrode Arrays: A Novel Type of Regenerative Peripheral Nerve Interface. https://app.cochat.ai/papers/10.1109/tnsre.2009.2031241
The paper
Lacour, S. P., Fitzgerald, J. J., Lago, N., Tarte, E., McMahon, S., & Fawcett, J. (2009). Long Micro-Channel Electrode Arrays: A Novel Type of Regenerative Peripheral Nerve Interface. IEEE Transactions on Neural Systems and Rehabilitation Engineering. https://doi.org/10.1109/tnsre.2009.2031241

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.