The effects of monoacrylated poly(ethylene glycol) on the properties of poly(ethylene glycol) diacrylate hydrogels used for tissue engineering
Open accessThe DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
This study investigated the effects of poly(ethylene glycol) monoacrylate (PEGMA) on the properties of poly(ethylene glycol) diacrylate (PEGDA)‐co‐PEGMA hydrogel networks. The PEGMA materials utilized were similar to ligand‐linked materials typically copolymerized with PEGDA for use as tissue engineering scaffolds. PEGDA (5–20% wt/wt, 6 kDa) and PEGMA (0–20% wt/wt, 0–43 m M, 5 kDa) were copolymerized by photo‐initiated free radical polymerization and the mass swelling ratio and shear modulus of the resulting hydrogels were determined. Increasing the prepolymerization concentration of PEGMA decreased the swelling ratio by up to 42 ± 1.6% and increased the shear modulus by up to 167 ± 29.3%, suggesting that PEGMA enhanced gel cross‐linking. Analysis of the effective number of cross‐linked chains per PEGDA, calculated independently from swelling and mechanical data, indicated each PEGDA participated in more cross‐links as PEGMA was added. The results suggest that PEGMA‐co‐PEGDA gels can be formed with higher concentrations of PEGMA‐tethered ligands than previously reported allowing the formation of scaffolds with a rich diversity of biological functionalities without sacrificing the integrity of the gel network. © 2009 Wiley Periodicals, Inc. J Biomed Mater Res, 2010
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Odian, G. (2004) · doi:10.1002/047147875x · Cited by 7,158
Lutolf, M. P., Lauer-Fields, J. L., Schmoekel, H. G., Metters, A. T., Weber, F. E., Fields, G. B., & Hubbell, J. A. (2003) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0737381100 · Cited by 1,508 · cited 1×
“1), (2) there is no appropriate Mn to characterize the long polymer chains from which the network is to be sub-divided, and (3) the Bray-Merrill model does not account for the PEGMA component of the copolymer gels, ve better characterizes PEGDA and PEGDA-co-PEGMA systems.”
BackgroundBurdick, J. A., & Anseth, K. S. (2002) · Biomaterials · doi:10.1016/s0142-9612(02)00176-x · Cited by 1,008
Bryant, S. J., & Anseth, K. S. (2002) · Journal of Biomedical Materials Research · doi:10.1002/jbm.1217 · Cited by 845
Cited by
Biomedical applications of biodegradable polymers
Ulery, B. D., Nair, L. S., & Laurencin, C. T. (2011) · Journal of Polymer Science Part B: Polymer Physics · doi:10.1002/polb.22259 · Cited by 2,206
Bioactive modification of poly (ethylene glycol) hydrogels for tissue engineering
Zhu, J. (2010) · Biomaterials · doi:10.1016/j.biomaterials.2010.02.044 · Cited by 1,457
Self-citationDesign properties of hydrogel tissue-engineering scaffolds
Zhu, J., & Marchant, R. E. (2011) · Expert Review of Medical Devices · doi:10.1586/erd.11.27 · Cited by 1,430
Self-citationRecent advances on the development of wound dressings for diabetic foot ulcer treatment—A review
Moura, L. I. F., Dias, A. M. A., Carvalho, E., & de Sousa, H. C. (2013) · Acta Biomaterialia · doi:10.1016/j.actbio.2013.03.033 · Cited by 778
Piezoelectric polymers as biomaterials for tissue engineering applications
Ribeiro, C., Sencadas, V., Correia, D. M., & Lanceros-Méndez, S. (2015) · Colloids and Surfaces B: Biointerfaces · doi:10.1016/j.colsurfb.2015.08.043 · Cited by 521
Metadata
- Authors
- Beamish, J. A., Zhu, J., Kottke‐Marchant, K., & Marchant, R. E.
- Venue
- Journal of Biomedical Materials Research Part A
- Publisher
- Wiley
- Published
- 2009-02-03
- Volume
- 92A
- Issue
- 2
- Pages
- 441-450
- ISSN
- 1549-3296 (ISSN-L)
- 1552-4965
- OpenAlex
- W2058293711
- Cited by
- 131
- References
- 4
- FWCI
- 2.48
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.