Host protection against deliberate bacterial contamination of an extracellular matrix bioscaffold versus Dacron™ mesh in a dog model of orthopedic soft tissue repair
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
The resistance of two biomaterials, one synthetic and one biologic in origin, to deliberate bacterial infection was compared in a dog model of orthopedic soft tissue reconstruction. Twenty‐four adult female dogs were randomly divided into two equal groups and a 2.0‐cm‐round full‐thickness defect was created on the lateral surface of the stifle joint, leaving only the synovium and skin intact. The defect was surgically repaired with either Dacron™ mesh or a porcine derived extracellular matrix (ECM) scaffold material. The repair site was inoculated with 1 × 10 8 Staphylococcus aureus at the time of surgery and the dogs were survived for 28 days. Results showed a chronic pyogranulomatous inflammatory response at the Dacron™ implant sites versus a constructive tissue‐remodeling response without residual inflammation at the ECM implant site. Three dogs in the group receiving the Dacron™ mesh were treated with Keflex™ (500 mg bid × 7 days) for signs of septicemia. A quantitative bacterial count of the implant sites at the time of sacrifice showed 6.52 × 10 5 ± 1.2 × 10 6 and 6.5 × 10 2 ± 1.8 × 10 3 bacteria per gram of tissue for the Dacron™ and ECM scaffold sites, respectively (P < .03). The ECM implant material was more resistant than the synthetic implant material to persistent infection following deliberate bacterial contamination and the ECM scaffold supported constructive tissue remodeling. © 2003 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater 67B: 648–654, 2003
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Identification of extractable growth factors from small intestinal submucosa
Voytik-Harbin, S. L., Brightman, A. O., Kraine, M. R., Waisner, B., & Badylak, S. F. (1997) · Journal of Cellular Biochemistry · doi:10.1002/(sici)1097-4644(19971215)67:4<478::aid-jcb6>3.0.co;2-p · Cited by 646
Self-citation
Cited by
The extracellular matrix as a biologic scaffold material
Badylak, S. F. (2007) · Biomaterials · doi:10.1016/j.biomaterials.2007.04.043 · Cited by 1,022
Self-citationImmune response to biologic scaffold materials
Badylak, S. F., & Gilbert, T. W. (2008) · Seminars in Immunology · doi:10.1016/j.smim.2007.11.003 · Cited by 857
Self-citationXenogeneic extracellular matrix as a scaffold for tissue reconstruction
Badylak, S. F. (2004) · Transplant Immunology · doi:10.1016/j.trim.2003.12.016 · Cited by 747
Self-citationMacrophage Participation in the Degradation and Remodeling of Extracellular Matrix Scaffolds
Valentin, J. E., Stewart-Akers, A. M., Gilbert, T. W., & Badylak, S. F. (2009) · Tissue Engineering Part A · doi:10.1089/ten.tea.2008.0419 · Cited by 356
Self-citationBrennan, E. P., Reing, J., Chew, D., Myers-Irvin, J. M., Young, E. J., & Badylak, S. F. (2006) · Tissue Engineering · doi:10.1089/ten.2006.12.2949 · Cited by 239
Self-citation
Metadata
- Authors
- Badylak, S. F., Ching Wu, C., Bible, M., & McPherson, E.
- Venue
- Journal of Biomedical Materials Research Part B: Applied Biomaterials
- Publisher
- Wiley
- Published
- 2003-09-12
- Volume
- 67B
- Issue
- 1
- Pages
- 648-654
- ISSN
- 1552-4973 (ISSN-L)
- 1552-4981
- OpenAlex
- W2008836611
- Cited by
- 62
- References
- 1
- FWCI
- 2.51
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.