The DOI matches its Crossref record; 46 of the 46 references it cites were found in a registry or an index.
Injectable bone cements for use in vertebroplasty and kyphoplasty: State‐of‐the‐art review
Abstract
Vertebroplasty (VP) and kyphoplasty (KP) are minimally invasive surgical procedures that have recently been introduced for the medical management of osteoporosis‐induced vertebral compression fractures. The aim of VP is to stabilize the fractured vertebral body, while the goals of KP are to stabilize the fractured vertebral body and to restore its height to as near its prefracture level as possible. Both procedures involve injection of the setting dough of an injectable bone cement (IBC) into the fractured vertebral body, thereby highlighting the indispensable role that the IBC plays. Although there is a very large literature on IBCs, no detailed critical review of it has been published. Such a review is the subject of the present work, which is in seven parts. The review opens with a succinct introduction to VP and KP. The topics covered in the parts that follow are: (1) a listing of the 18 most desirable properties of an IBC (e.g., easy injectability, high radiopacity, and a resorption rate that is neither too high nor too low); (2) descriptions of the four classes of IBCs (calcium phosphates, acrylic bone cements, calcium sulfates, and composites); (3) concerns that have been raised with regard to the use of IBCs (such as the potential for thermal necrosis of tissue at the peri‐augmentation site, when an acrylic bone cement is used); (4) explicative summaries of the main findings of literature studies on the influence of nine factors (such as powder particle size, powder‐to‐liquid ratio, and the method used to mix the powder and the liquid) on the values of various properties of IBCs; (5) explicative summaries of the main findings of literature studies on five fundamental matters, such as the aging mechanism of the powder, the thermokinetics of a setting dough, and the influence of the type of IBC used on various ex vivo biomechanical performance measures of VP‐ and KP‐augmented vertebral bodies; and (6) descriptions of topics in six areas for future research, such as the determination of an overall index of the fatigue performance of an IBC and the development of internationally recognized standardized testing protocols to employ when a synthetic cancellous bone void model is used in the rapid in vitro screening of IBCs. The review ends with a summary of the most salient points and observations made. © 2005 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 2006
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Preparation and assessment of revised simulated body fluids
Oyane, A., Kim, H., Furuya, T., Kokubo, T., Miyazaki, T., & Nakamura, T. (2003) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.10482 · Cited by 1,117
Vertebral Fractures and Mortality in Older Women: A Prospective Study
Kado, D. M. (1999) · Archives of Internal Medicine · doi:10.1001/archinte.159.11.1215 · Cited by 1,039
Calcium orthophosphates in medicine: from ceramics to calcium phosphate cements
Bohner, M. (2000) · Injury · doi:10.1016/s0020-1383(00)80022-4 · Cited by 982
Properties of acrylic bone cement: State of the art review
Lewis, G. (1997) · Journal of Biomedical Materials Research · doi:10.1002/(sici)1097-4636(199722)38:2<155::aid-jbm10>3.0.co;2-c · Cited by 744
Self-citationO'Neill, D. D. A. M. G. A. J. W. D. L. A. A. J. C. J. R. B. W. S. K. I. J. O. J. G. V. A. R. G. P. C. T. G. H. G. H. D. W. N. J. C. K. A. O. J. T. W. F. S. L. A. I. F. C. B. B. B. B. C. C. D. E. F. G. H. H. J. J. J. K. K. L. L. L. M. M. M. P. P. P. R. R. R. S. S. T. W. W. Y. R. (2002) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.2002.17.4.716 · Cited by 718
The clinical consequences of vertebral compression fracture
SILVERMAN, S. (1992) · Bone · doi:10.1016/8756-3282(92)90193-z · Cited by 657
The use of a quadruped as an in vivo model for the study of the spine – biomechanical considerations
Smit, T. H. (2002) · European Spine Journal · doi:10.1007/s005860100346 · Cited by 486
Injectability of calcium phosphate pastes
Bohner, M., & Baroud, G. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2004.05.010 · Cited by 395
Epidemiology of Spinal Osteoporosis
Melton, J. L. (1997) · Spine · doi:10.1097/00007632-199712151-00002 · Cited by 393
In vivo behavior of three different injectable hydraulic calcium phosphate cements
Apelt, D., Theiss, F., El-Warrak, A. O., Zlinszky, K., Bettschart-Wolfisberger, R., Bohner, M., Matter, S., Auer, J. A., & von Rechenberg, B. (2004) · Biomaterials · doi:10.1016/j.biomaterials.2003.08.073 · Cited by 372
Biomechanical and Histological Evaluation of a Calcium Phosphate Cement*
FRAKENBURG, E. P., GOLDSTEIN, S. A., BAUER, T. W., HARRIS, S. A., & POSER, R. D. (1998) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-199808000-00004 · Cited by 362
Ginebra, M. P., Driessens, F. C. M., & Planell, J. A. (2004) · Biomaterials · doi:10.1016/j.biomaterials.2003.10.049 · Cited by 322
Gbureck, U., Barralet, J. E., Spatz, K., Grover, L. M., & Thull, R. (2004) · Biomaterials · doi:10.1016/j.biomaterials.2003.08.066 · Cited by 274
Biomechanics of the aging spine
Ferguson, S. J., & Steffen, T. (2003) · European Spine Journal · doi:10.1007/s00586-003-0621-0 · Cited by 257
CALCIUM SULFATE– AND CALCIUM PHOSPHATE–BASED BONE SUBSTITUTES
Tay, B. K. B., Patel, V. V., & Bradford, D. S. (1999) · Orthopedic Clinics of North America · doi:10.1016/s0030-5898(05)70114-0 · Cited by 221
Minimally Invasive Treatments of Osteoporotic Vertebral Compression Fractures
Phillips, F. M. (2003) · Spine · doi:10.1097/01.brs.0000076898.37566.32 · Cited by 211
Barralet, J. E., Gaunt, T., Wright, A. J., Gibson, I. R., & Knowles, J. C. (2002) · Journal of Biomedical Materials Research · doi:10.1002/jbm.1074 · Cited by 209
Some factors controlling the injectability of calcium phosphate bone cements
Khairoun, I., Boltong, M. G., Driessens, F. C. M., & Planell, J. A. (1998) · Journal of Materials Science: Materials in Medicine · doi:10.1023/a:1008811215655 · Cited by 207
Recognizing and reporting osteoporotic vertebral fractures
Grigoryan, M., Guermazi, A., Roemer, F. W., Delmas, P. D., & Genant, H. K. (2003) · European Spine Journal · doi:10.1007/s00586-003-0613-0 · Cited by 202
Osteotransductive bone cements
Driessens, F. C. M., Planell, J. A., Boltong, M. G., Khairoun, I., & Ginebra, M. P. (1998) · Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine · doi:10.1243/0954411981534196 · Cited by 180
Kühn, K.-D. (2000) · Springer eBooks · doi:10.1007/978-3-642-59762-6 · Cited by 174
Kinetics of Hydroxyapatite Formation at Low Temperature
Brown, P. W., & Fulmer, M. (1991) · Journal of the American Ceramic Society · doi:10.1111/j.1151-2916.1991.tb04324.x · Cited by 168
Effect of added gelatin on the properties of calcium phosphate cement
Bigi, A., Bracci, B., & Panzavolta, S. (2004) · Biomaterials · doi:10.1016/j.biomaterials.2003.09.059 · Cited by 162
Adachi, J. D., Ioannidis, G., Olszynski, W. P., Brown, J. P., Hanley, D. A., Sebaldt, R. J., Petrie, A., Tenenhouse, A., Stephenson, G. F., Papaioannou, A., et al. (2002) · BMC Musculoskeletal Disorders · doi:10.1186/1471-2474-3-11 · Cited by 160
Barralet, J. E., Grover, L. M., & Gbureck, U. (2003) · Biomaterials · doi:10.1016/j.biomaterials.2003.09.085 · Cited by 157
Bone substitutes in vertebroplasty
Heini, P., & Berlemann, U. (2001) · European Spine Journal · doi:10.1007/s005860100308 · Cited by 153
Kinetic study of citric acid influence on calcium phosphate bone cements as water‐reducing agent
Sarda, S., Fernández, E., Nilsson, M., Balcells, M., & Planell, J. A. (2002) · Journal of Biomedical Materials Research · doi:10.1002/jbm.10264 · Cited by 140
Ginebra, M., Rilliard, A., Fern�ndez, E., Elvira, C., Rom�n, J. S., & Planell, J. A. (2001) · Journal of Biomedical Materials Research · Cited by 138
A novel injectable bioactive bone cement for spinal surgery: A developmental and preclinical study
Li, Y. W., Leong, J. C. Y., Lu, W. W., Luk, K. D. K., Cheung, K., Chiu, P., & Chow, S. P. (2000) · Journal of Biomedical Materials Research · doi:10.1002/1097-4636(200010)52:1<164::aid-jbm21>3.0.co;2-r · Cited by 135
Biomechanical comparison of calf and human spines
Wilke, H., Krischak, S., & Claes, L. (1996) · Journal of Orthopaedic Research® · doi:10.1002/jor.1100140321 · Cited by 119
Calcium Sulfate Bone Void Filler: A Review and a Look Ahead
Pietrzak, W. S., & Ronk, R. (2000) · Journal of Craniofacial Surgery · doi:10.1097/00001665-200011040-00009 · Cited by 119
Kyphoplasty and Vertebroplasty for the Treatment of Painful Osteoporotic Compression Fractures
Garfin, S. R., & Reiley, M. A. (2001) · Cited by 108
Kurtz, S. M., Villarraga, M. L., Zhao, K., & Edidin, A. A. (2004) · Biomaterials · doi:10.1016/j.biomaterials.2004.09.055 · Cited by 107
Takechi, M., Miyamoto, Y., Ishikawa, K., Nagayama, M., Kon, M., Asaoka, K., & Suzuki, K. (1998) · Journal of Biomedical Materials Research · doi:10.1002/(sici)1097-4636(199802)39:2<308::aid-jbm19>3.0.co;2-8 · Cited by 105
Chow, L. C., Hirayama, S., Takagi, S., & Parry, E. (2000) · Journal of Biomedical Materials Research · Cited by 101
Liu, C. (2003) · Biomaterials · doi:10.1016/s0142-9612(03)00238-2 · Cited by 94
An ex vivo biomechanical evaluation of a hydroxyapatite cement for use with kyphoplasty.
Belkoff, S. M., Mathis, J. M., Deramond, H., & Jasper, L. E. (2001) · PubMed Central · Cited by 81
Morgan, E. F., Yetkinler, D. N., Constantz, B. R., & Dauskardt, R. H. (1997) · Journal of Materials Science Materials in Medicine · doi:10.1023/a:1018550831834 · Cited by 79
Otsuka, M., Matsuda, Y., Yu, D., Wong, J., Fox, J. L., & Higuchi, W. I. (1990) · Chemical and Pharmaceutical Bulletin · doi:10.1248/cpb.38.3500 · Cited by 74
Eriksson, F., Mattsson, P., & Larsson, S. (2002) · Journal of Orthopaedic Trauma · doi:10.1097/00005131-200205000-00003 · Cited by 70
Otsuka, M., Matsuda, Y., Suwa, Y., Fox, J. L., & Higuchi, W. I. (1995) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820290105 · Cited by 67
Development of bioactive bone cement and its clinical applications
Yamamuro, T., Nakamura, T., Iida, H., et al. (1998) · Biomaterials · doi:10.1016/s0142-9612(98)00062-3 · Cited by 66
Temperature elevation during knee arthroplasty
Larsen, S., & Ryd, L. (1989) · Acta Orthopaedica Scandinavica · doi:10.3109/17453678909149314 · Cited by 62
Chen, W., Lin, J. C., & Ju, C. P. (2003) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.10250 · Cited by 58
Influence of sterilization on injectable bone biomaterials
Zahraoui, C., & Sharrock, P. (1999) · Bone · doi:10.1016/s8756-3282(99)00136-2 · Cited by 47
Zeineddine, S., & Knight, R. Q. (2003) · CRC Press eBooks · doi:10.1201/9780203912935.ch52 · Cited by 3
Cited by
Navarro, M., Michiardi, A., Castaño, O., & Planell, J. A. (2008) · Journal of The Royal Society Interface · doi:10.1098/rsif.2008.0151 · Cited by 1,513
Calcium phosphate cements for bone substitution: Chemistry, handling and mechanical properties
Zhang, J., Liu, W., Schnitzler, V., Tancret, F., & Bouler, J.-M. (2014) · Acta Biomaterialia · doi:10.1016/j.actbio.2013.11.001 · Cited by 667
Calcium phosphate cements as drug delivery materials
Ginebra, M.-P., Canal, C., Espanol, M., Pastorino, D., & Montufar, E. B. (2012) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2012.01.008 · Cited by 540
Calcium phosphate cements for bone engineering and their biological properties
Xu, H. H., Wang, P., Wang, L., Bao, C., Chen, Q., Weir, M. D., Chow, L. C., Zhao, L., Zhou, X., & Reynolds, M. A. (2017) · Bone Research · doi:10.1038/boneres.2017.56 · Cited by 409
Resorbable biomaterials as bone graft substitutes
Bohner, M. (2010) · Materials Today · doi:10.1016/s1369-7021(10)70014-6 · Cited by 405
Metadata
- Authors
- Lewis, G.
- Venue
- Journal of Biomedical Materials Research Part B: Applied Biomaterials
- Publisher
- Wiley
- Published
- 2005-09-29
- Volume
- 76B
- Issue
- 2
- Pages
- 456-468
- ISSN
- 1552-4973 (ISSN-L)
- 1552-4981
- OpenAlex
- W2011091784
- Cited by
- 280
- References
- 46
- FWCI
- 8.53
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.