In vitro and in vivo evaluation of ultrananocrystalline diamond for coating of implantable retinal microchips
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
In this work, ultrananocrystalline diamond (UNCD) thin films were evaluated for use as hermetic and bioinert coatings for a retinal microchip. These films were deposited on highly conductive Si substrates at different temperatures (from 400 to 800°C), using microwave plasma enhanced chemical vapor deposition with argon‐rich Ar/CH 4 gas mixtures and different relative amounts of hydrogen (0–20%). Scanning electron microscopy studies showed that all the films are dense and continuous. Results of cyclic voltammetry test revealed that when there was <2% of hydrogen in the plasma, the film obtained renders the surface electrochemically inactive, with very low leakage currents (∼4 × 10−7 A/cm 2 at ±5 V). In addition, in vivo tests of the UNCD‐coated Si samples were performed by implanting them in the eyes of rabbits for 4–6 months within the eye physiological environment. According to all these results, it was concluded that UNCD is a promising candidate for use as the encapsulating coatings for implantable retinal microelectronic devices. © 2005 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 2006
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Weiland, J. D., Liu, W., & Humayun, M. S. (2005) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.7.060804.100435 · Cited by 371
Self-citationBiostability of micro‐photodiode arrays for subretinal implantation
Hämmerle, H., Kobuch, K., Kohler, K., Nisch, W., Sachs, H., & Stelzle, M. (2002) · Biomaterials · doi:10.1016/s0142-9612(01)00185-5 · Cited by 146
Cited by
Nanodiamond Particles: Properties and Perspectives for Bioapplications
Schrand, A. M., Hens, S. A. C., & Shenderova, O. A. (2009) · Critical Reviews in Solid State and Materials Sciences · doi:10.1080/10408430902831987 · Cited by 802
A Materials Roadmap to Functional Neural Interface Design
Wellman, S. M., Eles, J. R., Ludwig, K. A., Seymour, J. P., Michelson, N. J., McFadden, W. E., Vazquez, A. L., & Kozai, T. D. Y. (2018) · Advanced Functional Materials · doi:10.1002/adfm.201701269 · Cited by 389
Encapsulation of an Integrated Neural Interface Device With Parylene C
Hsu, J.-M., Rieth, L., Normann, R. A., Tathireddy, P., & Solzbacher, F. (2009) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2008.2002155 · Cited by 241
“polyimide have compromised its application in neural interface encapsulation [7].”
BackgroundWeiland, J. D., & Humayun, M. S. (2014) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2014.2314733 · Cited by 186
Self-citationWeiland, J. D., & Humayun, M. S. (2008) · Proceedings of the IEEE · doi:10.1109/jproc.2008.922589 · Cited by 179
Self-citation
Metadata
- Authors
- Xiao, X., Wang, J., Liu, C., Carlisle, J. A., Mech, B., Greenberg, R., Guven, D., Freda, R., Humayun, M. S., Weiland, J., & Auciello, O.
- Venue
- Journal of Biomedical Materials Research Part B: Applied Biomaterials
- Publisher
- Wiley
- Published
- 2005-10-21
- Volume
- 77B
- Issue
- 2
- Pages
- 273-281
- ISSN
- 1552-4973 (ISSN-L)
- 1552-4981
- OpenAlex
- W2036129547
- Cited by
- 140
- References
- 2
- FWCI
- 2.26
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: In vitro and in vivo evaluation of ultrananocrystalline diamond for coating of implantable retinal microchips. https://app.cochat.ai/papers/10.1002/jbm.b.30448
- The paper
- Xiao, X., Wang, J., Liu, C., Carlisle, J. A., Mech, B., Greenberg, R., Guven, D., Freda, R., Humayun, M. S., Weiland, J., & Auciello, O. (2006). In vitro and in vivo evaluation of ultrananocrystalline diamond for coating of implantable retinal microchips. Journal of Biomedical Materials Research Part B: Applied Biomaterials. https://doi.org/10.1002/jbm.b.30448
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.