CoChat

Biostability of micro‐photodiode arrays for subretinal implantation

Hämmerle, Hugo, Kobuch, Karin, Kohler, Konrad, Nisch, Wilfried, Sachs, Helmut, Stelzle, Martin · 2002 · Biomaterials

The DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.

Abstract

Micro-photodiode arrays based on semiconductor chip technology are being developed to replace degenerated photoreceptor cells in the retina. Electric current is generated in tiny micro-photodiodes and delivered to the adjacent tissue by micro-electrodes. One of the main requirements of a sub-retinal implantable device is long-term stability versus corrosion in vivo (biostability). Biostability of micro-photodiode arrays (MPDA) was investigated in vitro and in vivo. No significant damage was found on chips immersed for up to 21 months in saline solution. Under in vivo conditions, however, the silicon oxide passivation layer of the chip was dissolved within a period of about 6-12 months. Subsequently, the underlying silicon was corroded. In contrast, stimulation electrodes consisting of titanium nitride were well preserved both in vitro and in vivo. The deterioration of the electrical properties of the micro-photodiodes correlated with the morphological damage observed. Strategies aiming at the development of an improved biostable encapsulation of neurotechnological implants have to be investigated and will be discussed briefly.

Overview

Integrity signals

Registry

Crossref · 10.1016/s0142-9612(01)00185-5

Cites

15 of 15 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 15 references

Research works printed but not linked: 2

  1. Chow, 1993, Electrical stimulation of the rabbit retina with subretinal electrodes and high density microphotodiode array implants, Invest Ophtalmol Vis Sci (Suppl), 34, 835
  2. Chow, 1998, Retinal and cortical potentials induced by subretinally implanted microphotodiode arrays, Invest Ophthalmol Vis Sci (Suppl), 39, 565

Cited by

See all 146

Metadata

Authors
Hämmerle, H., Kobuch, K., Kohler, K., Nisch, W., Sachs, H., & Stelzle, M.
Affiliations
  • Natural and Medical Sciences Institute (DE)
  • University Hospital Regensburg (DE)
Corresponding author
Stelzle, Martin
Venue
Biomaterials
Publisher
Elsevier BV
Published
2002-02
Volume
23
Issue
3
Pages
797-804
ISSN
0142-9612 (ISSN-L)
OpenAlex
W2050430198
Cited by
146
References
15
Citations by year
2025: 2 · 2024: 2 · 2023: 4 · 2022: 3 · 2021: 8 · 2020: 4 · 2019: 10 · 2018: 10 · 2017: 8 · 2016: 11 · 2015: 4 · 2014: 7 · 2013: 8 · 2012: 8
FWCI
2.56
Type
journal article
Language
en
Open access
closed
Licence
www.elsevier.com/tdm/userlicense/1.0/ (tdm)
Locations
  • Biomaterials (publishedVersion)
  • PubMed (publishedVersion)
  • University of Regensburg Publication Server (University of Regensburg) (acceptedVersion)
Topics
  • Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
  • Health Sciences › Medicine › Ophthalmology › Retinal Development and Disorders
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › CCD and CMOS Imaging Sensors
Keywords
subretinal implant, biostability, titanium nitride electrodes, retinal prosthesis, implant encapsulation, saline immersion
MeSH terms
Animals, Electrodes, Implanted, Humans, Retina, Swine, Swine, Miniature, Vitreous Body, Eye Enucleation, Prostheses and Implants, Photoreceptor Cells, Vertebrate

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Biostability of micro‐photodiode arrays for subretinal implantation. https://app.cochat.ai/papers/10.1016/s0142-9612(01)00185-5
The paper
Hämmerle, H., Kobuch, K., Kohler, K., Nisch, W., Sachs, H., & Stelzle, M. (2002). Biostability of micro‐photodiode arrays for subretinal implantation. Biomaterials. https://doi.org/10.1016/s0142-9612(01)00185-5

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.