Biostability of micro‐photodiode arrays for subretinal implantation
The DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.
Abstract
Micro-photodiode arrays based on semiconductor chip technology are being developed to replace degenerated photoreceptor cells in the retina. Electric current is generated in tiny micro-photodiodes and delivered to the adjacent tissue by micro-electrodes. One of the main requirements of a sub-retinal implantable device is long-term stability versus corrosion in vivo (biostability). Biostability of micro-photodiode arrays (MPDA) was investigated in vitro and in vivo. No significant damage was found on chips immersed for up to 21 months in saline solution. Under in vivo conditions, however, the silicon oxide passivation layer of the chip was dissolved within a period of about 6-12 months. Subsequently, the underlying silicon was corroded. In contrast, stimulation electrodes consisting of titanium nitride were well preserved both in vitro and in vivo. The deterioration of the electrical properties of the micro-photodiodes correlated with the morphological damage observed. Strategies aiming at the development of an improved biostable encapsulation of neurotechnological implants have to be investigated and will be discussed briefly.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“If parts of standard electronic processes were directly transferred for implant passivation, degradation during implantation deteriorated not only the insulation layer but also functional integrated structures within 1 year (Haemmerle et al., 2002)”
From A critical review of interfaces with the peripheral nervous system for the control of neuroprostheses and hybrid bionic systems (2005) · cites this paper as Haemmerle et al., 2002
Citations
Cites
Electrochemical Methods: Fundamentals and Applications
Bard, A. J., & Faulkner, L. R. (1980) · Cited by 22,821
Visual Perception Elicited by Electrical Stimulation of Retina in Blind Humans
Humayun, M. S. (1996) · Archives of Ophthalmology · doi:10.1001/archopht.1996.01100130038006 · Cited by 601 · cited 1×
“the neuronal network, survive for an extended period of time [1,2].”
BackgroundPattern electrical stimulation of the human retina
Humayun, M. S., de Juan Jr., E., Weiland, J. D., Dagnelie, G., Katona, S., Greenberg, R., & Suzuki, S. (1999) · Vision Research · doi:10.1016/s0042-6989(99)00052-8 · Cited by 592 · cited 1×
“the neuronal network, survive for an extended period of time [1,2].”
BackgroundCan subretinal microphotodiodes successfully replace degenerated photoreceptors?
Zrenner, E., Stett, A., Weiss, S., Aramant, R. B., Guenther, E., Kohler, K., Miliczek, K.-D., Seiler, M. J., & Haemmerle, H. (1999) · Vision Research · doi:10.1016/s0042-6989(98)00312-5 · Cited by 290
Learning Retina Implants with Epiretinal Contacts
Eckmiller, R. (1997) · Ophthalmic Research · doi:10.1159/000268026 · Cited by 257 · cited 1×
“Only quite recently implants intended for functional stimulation of neurons in the retina have been developed and implanted into animal models [10–13,3,4].”
MethodSubretinal electrical stimulation of the rabbit retina
Chow, A. Y., & Chow, V. Y. (1997) · Neuroscience Letters · doi:10.1016/s0304-3940(97)00185-7 · Cited by 242 · cited 1×
“[5–8].”
Egert, U., Schlosshauer, B., Fennrich, S., Nisch, W., Fejtl, M., Knott, T., Müller, T., & Hämmerle, H. (1998) · Brain Research Protocols · doi:10.1016/s1385-299x(98)00013-0 · Cited by 241
Self-citationThe Development of Subretinal Microphotodiodes for Replacement of Degenerated Photoreceptors
Zrenner, E., Miliczek, K.-D., Gabel, V. P., Graf, H. G., Guenther, E., Haemmerle, H., Hoefflinger, B., Kohler, K., Nisch, W., Schubert, M., et al. (1997) · Ophthalmic Research · doi:10.1159/000268025 · Cited by 214 · cited 2×
“Prototype devices have already been implanted subretinally in animals between the neuronal layer and the pigment epithelium [3,4].”
BackgroundMethodSelf-citationBrummer, S. B., Robblee, L. S., & Hambrecht, F. T. (1983) · Annals of the New York Academy of Sciences · doi:10.1111/j.1749-6632.1983.tb31628.x · Cited by 205 · cited 1×
“02mC/cm are in good agreement with the earlier reports of capacitance measurements on planar stimulation electrodes [15].”
ResultBiomaterials used in the posterior segment of the eye
Colthurst, M. J., Williams, R. L., Hiscott, P. S., & Grierson, I. (2000) · Biomaterials · doi:10.1016/s0142-9612(99)00220-3 · Cited by 162 · cited 1×
“[9].”
Research works printed but not linked: 2
- Chow, 1993, Electrical stimulation of the rabbit retina with subretinal electrodes and high density microphotodiode array implants, Invest Ophtalmol Vis Sci (Suppl), 34, 835
- Chow, 1998, Retinal and cortical potentials induced by subretinally implanted microphotodiode arrays, Invest Ophthalmol Vis Sci (Suppl), 39, 565
Cited by
Small-scale systems for in vivo drug delivery
LaVan, D. A., McGuire, T., & Langer, R. (2003) · Nature Biotechnology · doi:10.1038/nbt876 · Cited by 1,304
Navarro, X., Krueger, T. B., Lago, N., Micera, S., Stieglitz, T., & Dario, P. (2005) · Journal of the Peripheral Nervous System · doi:10.1111/j.1085-9489.2005.10303.x · Cited by 845
“If parts of standard electronic processes were directly transferred for implant passivation, degradation during implantation deteriorated not only the insulation layer but also functional integrated structures within 1 year (Haemmerle et al., 2002).”
MethodNeural recording and modulation technologies
Chen, R., Canales, A., & Anikeeva, P. (2017) · Nature Reviews Materials · doi:10.1038/natrevmats.2016.93 · Cited by 655
Biocompatibility and biofouling of MEMS drug delivery devices
Voskerician, G., Shive, M. S., Shawgo, R. S., Recum, H. V., Anderson, J. M., Cima, M. J., & Langer, R. (2003) · Biomaterials · doi:10.1016/s0142-9612(02)00565-3 · Cited by 558
“Others have reported on the potential corrosion in vivo of a silicon oxide passivating layer occurring as early as 1 month in a sensor array, reducing the overall biocompatibility of the device over time [18,21,22].”
BackgroundControl of Hand Prostheses Using Peripheral Information
Micera, S., Carpaneto, J., & Raspopovic, S. (2010) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2010.2085429 · Cited by 403
Metadata
- Authors
- Hämmerle, H., Kobuch, K., Kohler, K., Nisch, W., Sachs, H., & Stelzle, M.
- Affiliations
- Natural and Medical Sciences Institute (DE)
- University Hospital Regensburg (DE)
- Corresponding author
- Stelzle, Martin
- ORCID
- Stelzle, Martin
- Venue
- Biomaterials
- Publisher
- Elsevier BV
- Published
- 2002-02
- Volume
- 23
- Issue
- 3
- Pages
- 797-804
- ISSN
- 0142-9612 (ISSN-L)
- OpenAlex
- W2050430198
- Cited by
- 146
- References
- 15
- Citations by year
- 2025: 2 · 2024: 2 · 2023: 4 · 2022: 3 · 2021: 8 · 2020: 4 · 2019: 10 · 2018: 10 · 2017: 8 · 2016: 11 · 2015: 4 · 2014: 7 · 2013: 8 · 2012: 8
- FWCI
- 2.56
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- Biomaterials (publishedVersion)
- PubMed (publishedVersion)
- University of Regensburg Publication Server (University of Regensburg) (acceptedVersion)
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Health Sciences › Medicine › Ophthalmology › Retinal Development and Disorders
- Physical Sciences › Engineering › Electrical and Electronic Engineering › CCD and CMOS Imaging Sensors
- Keywords
- subretinal implant, biostability, titanium nitride electrodes, retinal prosthesis, implant encapsulation, saline immersion
- MeSH terms
- Animals, Electrodes, Implanted, Humans, Retina, Swine, Swine, Miniature, Vitreous Body, Eye Enucleation, Prostheses and Implants, Photoreceptor Cells, Vertebrate
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Biostability of micro‐photodiode arrays for subretinal implantation. https://app.cochat.ai/papers/10.1016/s0142-9612(01)00185-5
- The paper
- Hämmerle, H., Kobuch, K., Kohler, K., Nisch, W., Sachs, H., & Stelzle, M. (2002). Biostability of micro‐photodiode arrays for subretinal implantation. Biomaterials. https://doi.org/10.1016/s0142-9612(01)00185-5
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.