The DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.
Selective Laser Melting: A regular unit cell approach for the manufacture of porous, titanium, bone in‐growth constructs, suitable for orthopedic applications
Abstract
In this study, a novel porous titanium structure for the purpose of bone in‐growth has been designed, manufactured and evaluated. The structure was produced by Selective Laser Melting (SLM); a rapid manufacturing process capable of producing highly intricate, functionally graded parts. The technique described utilizes an approach based on a defined regular unit cell to design and produce structures with a large range of both physical and mechanical properties. These properties can be tailored to suit specific requirements; in particular, functionally graded structures with bone in‐growth surfaces exhibiting properties comparable to those of human bone have been manufactured. The structures were manufactured and characterized by unit cell size, strand diameter, porosity, and compression strength. They exhibited a porosity (10–95%) dependant compression strength (0.5–350 Mpa) comparable to the typical naturally occurring range. It is also demonstrated that optimized structures have been produced that possesses ideal qualities for bone in‐growth applications and that these structures can be applied in the production of orthopedic devices. © 2008 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 2009
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Cellular solids structure and properties
Gibson, L. J., Ashby, M. F., et al. (1997) · Cited by 9,172
Cellular solids: Structure and properties
Wolcott, M. P. (1990) · Materials Science and Engineering: A · doi:10.1016/0921-5093(90)90295-e · Cited by 5,926
Manufacture, characterisation and application of cellular metals and metal foams
Banhart, J. (2001) · Progress in Materials Science · doi:10.1016/s0079-6425(00)00002-5 · Cited by 3,780
Ashby, M., Evans, A., Fleck, N., Gibson, L., Hutchinson, J., Wadley, H., & Delale, F. (2001) · Applied Mechanics Reviews · doi:10.1115/1.1421119 · Cited by 2,694
Mechanical properties and the hierarchical structure of bone
Rho, J.-Y., Kuhn-Spearing, L., & Zioupos, P. (1998) · Medical Engineering & Physics · doi:10.1016/s1350-4533(98)00007-1 · Cited by 2,588
Ashby, M. F., Evans, A., Fleck, N. A., Gibson, L. J., Hutchinson, J. W., & Wadley, H. N. G. (2002) · Materials & Design · doi:10.1016/s0261-3069(01)00049-8 · Cited by 2,367
The compressive behavior of bone as a two-phase porous structure
Carter, D., & Hayes, W. (1977) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-197759070-00021 · Cited by 2,001
Fabrication methods of porous metals for use in orthopaedic applications
Ryan, G., Pandit, A., & Apatsidis, D. P. (2006) · Biomaterials · doi:10.1016/j.biomaterials.2005.12.002 · Cited by 1,391
HUISKES, R., WEINANS, H., & RIETBERGEN, B. V. (1992) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-199201000-00014 · Cited by 1,213
Characteristics of bone ingrowth and interface mechanics of a new porous tantalum biomaterial
Bobyn, J. D., Stackpool, G. J., Hacking, S. A., Tanzer, M., & Krygier, J. J. (1999) · The Journal of Bone and Joint Surgery. British volume · doi:10.1302/0301-620x.81b5.0810907 · Cited by 1,037
Potential of ceramic materials as permanently implantable skeletal prostheses
Hulbert, S. F., Young, F. A., Mathews, R. S., Klawitter, J. J., Talbert, C. D., & Stelling, F. H. (1970) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820040309 · Cited by 1,019
The Optimum Pore Size for the Fixation of Porous-Surfaced Metal Implants by the Ingrowth of Bone
BOBYN, J. D., PILLIAR, R. M., CAMERON, H. U., & WEATHERLY, G. C. (1980) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-198007000-00045 · Cited by 832
Rapid manufacturing of metal components by laser forming
Santos, E. C., Shiomi, M., Osakada, K., & Laoui, T. (2006) · International Journal of Machine Tools and Manufacture · doi:10.1016/j.ijmachtools.2005.09.005 · Cited by 740
The mechanical properties of trabecular bone: Dependence on anatomic location and function
Goldstein, S. A. (1987) · Journal of Biomechanics · doi:10.1016/0021-9290(87)90023-6 · Cited by 687
Mechanical properties of porous titanium compacts prepared by powder sintering
Oh, I.-H., Nomura, N., Masahashi, N., & Hanada, S. (2003) · Scripta Materialia · doi:10.1016/j.scriptamat.2003.08.018 · Cited by 569
Absorptance of powder materials suitable for laser sintering
Tolochko, N. K., Khlopkov, Y. V., Mozzharov, S. E., Ignatiev, M. B., Laoui, T., & Titov, V. I. (2000) · Rapid Prototyping Journal · doi:10.1108/13552540010337029 · Cited by 518
Gebhardt, A. (2006) · Springer eBooks · doi:10.1007/10877768_4 · Cited by 461
The manufacturing of hard tools from metallic powders by selective laser melting
Abe, F., Osakada, K., Shiomi, M., Uematsu, K., & Matsumoto, M. (2001) · Journal of Materials Processing Technology · doi:10.1016/s0924-0136(01)00522-2 · Cited by 390
Structure, metallurgy, and mechanical properties of a porous tantalum foam
Zardiackas, L. D., Parsell, D. E., Dillon, L. D., Mitchell, D. W., Nunnery, L. A., & Poggie, R. (2001) · Journal of Biomedical Materials Research · doi:10.1002/1097-4636(2001)58:2<180::aid-jbm1005>3.0.co;2-5 · Cited by 362
Physical properties of trabecular bone
Galante, J., Rostoker, W., & Ray, R. D. (1970) · Calcified Tissue Research · doi:10.1007/bf02017552 · Cited by 302
Tissue response to porous tantalum acetabular cups
Bobyn, J., Toh, K.-K., Hacking, S. A., Tänzer, M., & Krygier, J. J. (1999) · The Journal of Arthroplasty · doi:10.1016/s0883-5403(99)90062-1 · Cited by 281
Laser-Induced Materials and Processes for Rapid Prototyping
Lü, L., Fuh, J. Y. H., & Wong, Y. S. (2001) · Springer eBooks · doi:10.1007/978-1-4615-1469-5 · Cited by 188
Mechanical properties of open‐pore titanium foam
Imwinkelried, T. (2007) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.31118 · Cited by 188
Assad, M., Jarzem, P. F., Leroux, M. A., Coillard, C., Chernyshov, A. V., Charette, S., & Rivard, C. (2003) · Journal of Biomedical Materials Research Part B Applied Biomaterials · doi:10.1002/jbm.b.10530 · Cited by 114
The Compressive Behavior of Bone as a Two-Phase Porous Structure
Wall, A., & Tim Board (2013) · Springer eBooks · doi:10.1007/978-1-4471-5451-8_116 · Cited by 93
Cited by
Review of selective laser melting: Materials and applications
Yap, C. Y., Chua, C. K., Dong, Z. L., Liu, Z. H., Zhang, D. Q., Loh, L. E., & Sing, S. L. (2015) · Applied Physics Reviews · doi:10.1063/1.4935926 · Cited by 2,353
Wang, X., Xu, S., Zhou, S., Xu, W., Leary, M., Choong, P., Qian, M., Brandt, M., & Xie, Y. M. (2016) · Biomaterials · doi:10.1016/j.biomaterials.2016.01.012 · Cited by 2,121
SLM lattice structures: Properties, performance, applications and challenges
Maconachie, T., Leary, M., Lozanovski, B., Zhang, X., Qian, M., Faruque, O., & Brandt, M. (2019) · Materials & Design · doi:10.1016/j.matdes.2019.108137 · Cited by 1,497
The future of dental devices is digital
van Noort, R. (2012) · Dental Materials · doi:10.1016/j.dental.2011.10.014 · Cited by 1,408
Manufacturing and processing of NiTi implants: A review
Elahinia, M. H., Hashemi, M., Tabesh, M., & Bhaduri, S. B. (2012) · Progress in Materials Science · doi:10.1016/j.pmatsci.2011.11.001 · Cited by 1,067
Metadata
- Authors
- Mullen, L., Stamp, R. C., Brooks, W. K., Jones, E., & Sutcliffe, C. J.
- Venue
- Journal of Biomedical Materials Research Part B: Applied Biomaterials
- Publisher
- Wiley
- Published
- 2008-10-06
- Volume
- 89B
- Issue
- 2
- Pages
- 325-334
- ISSN
- 1552-4973 (ISSN-L)
- 1552-4981
- OpenAlex
- W2048550500
- Cited by
- 410
- References
- 25
- FWCI
- 16.36
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.