The DOI matches its Crossref record.
Compression‐compression fatigue of selective electron beam melted cellular titanium (Ti‐6Al‐4V)
Abstract
Regular 3D periodic porous Ti‐6Al‐4V structures intended to reduce the effects of stress shielding in load‐bearing bone replacement implants (e.g., hip stems) were fabricated over a range of relative densities (0.17–0.40) and pore sizes (∼500–1500 μm) using selective electron beam melting (EBM). Compression‐compression fatigue testing (15 Hz,R= 0.1) resulted in normalized fatigue strengths at 10 6 cycles ranging from 0.15 to 0.25, which is lower than the expected value of 0.4 for solid material of the same acicular α microstructure. The three possible reasons for this reduced fatigue lifetime are stress concentrations from closed porosity observed within struts, stress concentrations from observed strut surface features (sintered particles and texture lines), and microstructure (either acicular α or martensite) with less than optimal high‐cycle fatigue resistance. © 2011 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 2011.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Taniguchi, N., Fujibayashi, S., Takemoto, M., Sasaki, K., Otsuki, B., Nakamura, T., Matsushita, T., Kokubo, T., & Matsuda, S. (2016) · Materials Science and Engineering: C · doi:10.1016/j.msec.2015.10.069 · Cited by 960
Benedetti, M., du Plessis, A., Ritchie, R. O., Dallago, M., Razavi, N., & Berto, F. (2021) · Materials Science and Engineering: R: Reports · doi:10.1016/j.mser.2021.100606 · Cited by 788
Yan, C., Hao, L., Hussein, A., & Young, P. (2015) · Journal of the Mechanical Behavior of Biomedical Materials · doi:10.1016/j.jmbbm.2015.06.024 · Cited by 717
Liu, Y. J., Li, S. J., Wang, H. L., Hou, W. T., Hao, Y. L., Yang, R., Sercombe, T. B., & Zhang, L. C. (2016) · Acta Materialia · doi:10.1016/j.actamat.2016.04.029 · Cited by 584
X-ray computed tomography for additive manufacturing: a review
Thompson, A., Maskery, I., & Leach, R. K. (2016) · Measurement Science and Technology · doi:10.1088/0957-0233/27/7/072001 · Cited by 521
Metadata
- Authors
- Hrabe, N. W., Heinl, P., Flinn, B., Körner, C., & Bordia, R. K.
- Venue
- Journal of Biomedical Materials Research Part B: Applied Biomaterials
- Publisher
- Wiley
- Published
- 2011-09-21
- Volume
- 99B
- Issue
- 2
- Pages
- 313-320
- ISSN
- 1552-4973 (ISSN-L)
- 1552-4981
- OpenAlex
- W2161513954
- Cited by
- 203
- References
- 0
- FWCI
- 9.11
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Compression‐compression fatigue of selective electron beam melted cellular titanium (Ti‐6Al‐4V). https://app.cochat.ai/papers/10.1002/jbm.b.31901
- The paper
- Hrabe, N. W., Heinl, P., Flinn, B., Körner, C., & Bordia, R. K. (2011). Compression‐compression fatigue of selective electron beam melted cellular titanium (Ti‐6Al‐4V). Journal of Biomedical Materials Research Part B: Applied Biomaterials. https://doi.org/10.1002/jbm.b.31901
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.