The DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.
Biodegradable and bioactive porous scaffold structures prepared using fused deposition modeling
Abstract
Three‐dimensional printing (3DP) refers to a group of additive manufacturing techniques that can be utilized in tissue engineering applications. Fused deposition modeling (FDM) is a 3DP method capable of using common thermoplastic polymers. However, the scope of materials applicable for FDM has not been fully recognized. The purpose of this study was to examine the creation of biodegradable porous scaffold structures using different materials in FDM and to determine the compressive properties and the fibroblast cell response of the structures. To the best of our knowledge, the printability of a poly(ε‐caprolactone)/bioactive glass (PCL/BAG) composite and L‐lactide/ε‐caprolactone 75/25 mol % copolymer (PLC) was demonstrated for the first time. Scanning electron microscope (SEM) images showed BAG particles at the surface of the printed PCL/BAG scaffolds. Compressive testing showed the possibility of altering the compressive stiffness of a scaffold without changing the compressive modulus. Compressive properties were significantly dependent on porosity level and structural geometry. Fibroblast proliferation was significantly higher in polylactide than in PCL or PCL/BAG composite. Optical microscope images and SEM images showed the viability of the cells, which demonstrated the biocompatibility of the structures. © 2012 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 2013.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Scaffolds in tissue engineering bone and cartilage
Hutmacher, D. W. (2000) · Biomaterials · doi:10.1016/s0142-9612(00)00121-6 · Cited by 4,994
Biodegradable and bioactive porous polymer/inorganic composite scaffolds for bone tissue engineering
Rezwan, K., Chen, Q. Z., Blaker, J. J., & Boccaccini, A. R. (2006) · Biomaterials · doi:10.1016/j.biomaterials.2006.01.039 · Cited by 3,839
A review on stereolithography and its applications in biomedical engineering
Melchels, F. P. W., Feijen, J., & Grijpma, D. W. (2010) · Biomaterials · doi:10.1016/j.biomaterials.2010.04.050 · Cited by 2,457
Fused deposition modeling of novel scaffold architectures for tissue engineering applications
Zein, I., Hutmacher, D. W., Tan, K. C., & Teoh, S. H. (2002) · Biomaterials · doi:10.1016/s0142-9612(01)00232-0 · Cited by 1,874
Bioactive glass in tissue engineering
Rahaman, M. N., Day, D. E., Sonny Bal, B., Fu, Q., Jung, S. B., Bonewald, L. F., & Tomsia, A. P. (2011) · Acta Biomaterialia · doi:10.1016/j.actbio.2011.03.016 · Cited by 1,794
Hutmacher, D. W., Schantz, T., Zein, I., Ng, K. W., Teoh, S. H., & Tan, K. C. (2001) · Journal of Biomedical Materials Research · doi:10.1002/1097-4636(200105)55:2<203::aid-jbm1007>3.0.co;2-7 · Cited by 1,409
Hutmacher, D. W., Sittinger, M., & Risbud, M. V. (2004) · Trends in Biotechnology · doi:10.1016/j.tibtech.2004.05.005 · Cited by 1,121
A review of rapid prototyping techniques for tissue engineering purposes
Peltola, S. M., Melchels, F. P. W., Grijpma, D. W., & Kellomäki, M. (2008) · Annals of Medicine · doi:10.1080/07853890701881788 · Cited by 751
Kricheldorf, H. R., Berl, M., & Scharnagl, N. (1988) · Macromolecules · doi:10.1021/ma00180a002 · Cited by 597
Composites by rapid prototyping technology
Kumar, S., & Kruth, J.-P. (2010) · Materials & Design · doi:10.1016/j.matdes.2009.07.045 · Cited by 463
The rapid prototyping technologies
Upcraft, S., & Fletcher, R. (2003) · Assembly Automation · doi:10.1108/01445150310698634 · Cited by 367
Suitability of PLA/TCP for fused deposition modeling
Drummer, D., Cifuentes‐Cuéllar, S., & Rietzel, D. (2012) · Rapid Prototyping Journal · doi:10.1108/13552541211272045 · Cited by 210
Darensbourg, D. J., & Karroonnirun, O. (2010) · Macromolecules · doi:10.1021/ma101784y · Cited by 178
Teo, E. Y., Ong, S.-Y., Khoon Chong, M. S., Zhang, Z., Lu, J., Moochhala, S., Ho, B., & Teoh, S.-H. (2011) · Biomaterials · doi:10.1016/j.biomaterials.2010.08.089 · Cited by 176
Rapid-prototyped PLGA/β-TCP/hydroxyapatite nanocomposite scaffolds in a rabbit femoral defect model
Kim, J., McBride, S., Tellis, B. C., Alvarez, P., Song, Y. H., Dean, D. D., Sylvia, V. L., Elgendy, H. M., Ong, J. L., & Hollinger, J. O. (2012) · Biofabrication · doi:10.1088/1758-5082/4/2/025003 · Cited by 153
Antibacterial effects of sol‐gel‐derived bioactive glass nanoparticle on aerobic bacteria
Mortazavi, V., Nahrkhalaji, M. M., Fathi, M., Mousavi, S. B., & Esfahani, B. N. (2010) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.32678 · Cited by 150
Yen, H., Tseng, C., Hsu, S., & Tsai, C. (2008) · Biomedical Microdevices · doi:10.1007/s10544-008-9271-7 · Cited by 116
Degradation characteristics of poly(ϵ‐caprolactone)‐based copolymers and blends
Huang, M., Li, S., Hutmacher, D. W., Coudane, J., & Vert, M. (2006) · Journal of Applied Polymer Science · doi:10.1002/app.24196 · Cited by 104
Chiriac, S. A., Facca, S., Diaconu, M., Gouzou, S., & Liverneaux, P. A. (2011) · Journal of Hand Surgery (European Volume) · doi:10.1177/1753193411422685 · Cited by 96
Kricheldorf, H. R., & Kreiser‐Saunders, I. (1987) · Journal of Macromolecular Science Part A - Chemistry · doi:10.1080/00222338708076950 · Cited by 72
Cited by
Recent advances in 3D printing of biomaterials
Chia, H. N., & Wu, B. M. (2015) · Journal of Biological Engineering · doi:10.1186/s13036-015-0001-4 · Cited by 1,734
Materials design for bone-tissue engineering
Koons, G. L., Diba, M., & Mikos, A. G. (2020) · Nature Reviews Materials · doi:10.1038/s41578-020-0204-2 · Cited by 1,699
A Comparative Review of Natural and Synthetic Biopolymer Composite Scaffolds
Reddy, M. S. B., Ponnamma, D., Choudhary, R., & Sadasivuni, K. K. (2021) · Polymers · doi:10.3390/polym13071105 · Cited by 1,104
Three-dimensional (3D) printed scaffold and material selection for bone repair
Zhang, L., Yang, G., Johnson, B. N., & Jia, X. (2019) · Acta Biomaterialia · doi:10.1016/j.actbio.2018.11.039 · Cited by 865
Recent Progress on Polymer Materials for Additive Manufacturing
Tan, L. J., Zhu, W., & Zhou, K. (2020) · Advanced Functional Materials · doi:10.1002/adfm.202003062 · Cited by 740
Metadata
- Authors
- Korpela, J., Kokkari, A., Korhonen, H., Malin, M., Närhi, T., & Seppälä, J.
- Venue
- Journal of Biomedical Materials Research Part B: Applied Biomaterials
- Publisher
- Wiley
- Published
- 2012-12-20
- Volume
- 101B
- Issue
- 4
- Pages
- 610-619
- ISSN
- 1552-4973 (ISSN-L)
- 1552-4981
- OpenAlex
- W2056984689
- Cited by
- 258
- References
- 20
- FWCI
- 4.71
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.