Biomimetic design of bone substitutes based on cuttlefish bone‐derived hydroxyapatite and biodegradable polymers
The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Abstract
Being a major component of bone tissue, hydroxyapatite is the most investigated calcium phosphate in the design and development of bone implants. The high brittleness and poor load‐bearing properties have led researchers to manipulate hydroxyapatite performance by applying polymer or metal materials. The present study focuses on biomimetic approach of the hydroxyapatite synthesis from the cuttlefish bone in order to preserve highly porous structure. The low stiffness of hydroxyapatite scaffold was altered by thin polycaprolactone/poly(lactic acid) coating, resulting in remarkably 18‐fold increase of Young's modulus. The mechanical test revealed that poly(lactic acid) increases the stiffness of composite scaffolds which depends on the polycaprolactone/poly(lactic acid) volume ratio. The composite scaffolds are bioactive supporting the deposition of new calcium phosphates when incubated in simulated physiological medium for 21 days. Moreover, the culture of human embryonic kidney cells indicated non‐cytotoxicity of the composite scaffolds with emphasis on the cell proliferation during three days of culture. © 2018 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 107B: 197–204, 2019.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Literature Review of Poly(Lactic Acid)
Garlotta, D. (2001) · Journal of Polymers and the Environment · doi:10.1023/a:1020200822435 · Cited by 3,707
Synthetic biodegradable polymers as orthopedic devices
Middleton, J. C., & Tipton, A. J. (2000) · Biomaterials · doi:10.1016/s0142-9612(00)00101-0 · Cited by 2,741
An overview of the recent developments in polylactide (PLA) research
Madhavan Nampoothiri, K., Nair, N. R., & John, R. P. (2010) · Bioresource Technology · doi:10.1016/j.biortech.2010.05.092 · Cited by 2,448
Pitt, G. G., Gratzl, M. M., Kimmel, G. L., Surles, J., & Sohindler, A. (1981) · Biomaterials · doi:10.1016/0142-9612(81)90060-0 · Cited by 857
FTIR study of polycaprolactone chain organization at interfaces
Elzein, T., Nasser-Eddine, M., Delaite, C., Bistac, S., & Dumas, P. (2004) · Journal of Colloid and Interface Science · doi:10.1016/j.jcis.2004.02.001 · Cited by 814
Osteoinductive ceramics as a synthetic alternative to autologous bone grafting
Yuan, H., Fernandes, H., Habibovic, P., de Boer, J., Barradas, A. M. C., de Ruiter, A., Walsh, W. R., van Blitterswijk, C. A., & de Bruijn, J. D. (2010) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1003600107 · Cited by 746
Ostafinska, A., Fortelny, I., Nevoralova, M., Hodan, J., Kredatusova, J., & Slouf, M. (2015) · RSC Advances · doi:10.1039/c5ra21178f · Cited by 176
CNT Induced β-Phase in Polylactide: Unique Crystallization, Biodegradation, and Biocompatibility
Singh, N. K., Singh, S. K., Dash, D., Gonugunta, P., Misra, M., & Maiti, P. (2013) · The Journal of Physical Chemistry C · doi:10.1021/jp4009042 · Cited by 68
Cited by
Balla, E., Daniilidis, V., Karlioti, G., Kalamas, T., Stefanidou, M., Bikiaris, N. D., Vlachopoulos, A., Koumentakou, I., & Bikiaris, D. N. (2021) · Polymers · doi:10.3390/polym13111822 · Cited by 655
Current applications of poly(lactic acid) composites in tissue engineering and drug delivery
Liu, S., Qin, S., He, M., Zhou, D., Qin, Q., & Wang, H. (2020) · Composites Part B: Engineering · doi:10.1016/j.compositesb.2020.108238 · Cited by 533
Fabrication of Biomedical Scaffolds Using Biodegradable Polymers.
Kirillova, A., Yeazel, T. R., Asheghali, D., Petersen, S. R., Dort, S., Gall, K., & Becker, M. L. (2021) · Chemical Reviews · doi:10.1021/acs.chemrev.0c01200 · Cited by 368
Biodegradable polycaprolactone (PCL) based polymer and composites
Archer, E., Torretti, M., & Madbouly, S. (2023) · Physical Sciences Reviews · doi:10.1515/psr-2020-0074 · Cited by 119
Zheng, T., Guo, L., Du, Z., Leng, H., Cai, Q., & Yang, X. (2021) · Ceramics International · doi:10.1016/j.ceramint.2021.03.234 · Cited by 39
Metadata
- Authors
- Rogina, A., Antunović, M., & Milovac, D.
- Venue
- Journal of Biomedical Materials Research Part B: Applied Biomaterials
- Publisher
- Wiley
- Published
- 2018-03-23
- Volume
- 107
- Issue
- 1
- Pages
- 197-204
- ISSN
- 1552-4973 (ISSN-L)
- 1552-4981
- OpenAlex
- W2793914265
- Cited by
- 53
- References
- 8
- FWCI
- 2.93
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.