Universal standardization for dual X-ray absorptiometry: Patient and phantom cross-calibration results
Abstract
The comparison of patient data among different dual x-ray absorptiometry (DXA) scanners is complicated because no universally accepted cross-calibration procedure or standard currently exists. This study was performed under the auspices of the International DXA Standardization Committee to establish appropriate cross-calibration parameters. Posteroanterior (PA) lumbar spine measurements of 100 women, ages 20–80 years (mean 52.6 + 16, range of BMD = 0.4–1.6 g/cm2) were obtained on a Norland XR26 Mark II, a Lunar DPX-L, and a Hologic QDR 2000 densitometer using standard procedures (pencil beam mode for all three scanners). Area, BMC, and BMD results from the different scanners were compared for all patients. In addition, the European spine phantom (ESP) and the European spine phantom prototype (ESP prototype), as well as standard phantoms from all three manufacturers, were evaluated on the three systems. To achieve universal scanner calibration, we used the intercept and slope of the patient's correlations and the value of the middle vertebra of the ESP as a reference point in a series of standardization formulas, and we have expressed the results as sBMD (mg/cm2). The correlations of the patients' spinal BMD values were excellent for each of the three scanner pairs. The average absolute difference in patient spinal BMD values (L2–4) between Hologic and Norland was 0.012 g/cm2 (1.3%); it was 0.113 g/cm2 (11.7%) between Hologic and Lunar and 0.118 g/cm2 (12.2%) between Norland and Lunar. The phantoms' regression lines approximated those of the patient regression lines, and the phantoms with only one measurement point were very close to the patients' regression lines. After applying the standardization formulas, the average absolute differences for the 100 patients were 28 mg/cm2 (2.7%) for Hologic/Norland, 23 mg/cm2 (2.2%) for Hologic/Lunar, and 29 mg/cm2 (2.8%) for Norland/Lunar. Average BMD results for the patients before correction were 0.972 g/cm2 for Hologic, 1.100 g/cm2 for Lunar, and 0.969 g/cm2 for Norland. After correction, sBMD results for patients were 1045 mg/cm2 for Hologic, 1047 mg/cm2 for Lunar, and 1043 mg/cm2 for Norland. The standardization approach as performed in our study provided compatibility of DXA results obtained on different scanners.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Axial and appendicular bone density predict fractures in older women
Black, D. M., Cummings, S. R., Genant, H. K., Nevitt, M. C., Palermo, L., & Browner, W. (1992) · Journal of Bone and Mineral Research · doi:10.1002/jbmr.5650070607 · Cited by 510
Self-citationMatkovic, V, Fontana, D., Tominac, C., Goel, P., & Chesnut, C. (1990) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/52.5.878 · Cited by 463
The contribution of bone loss to postmenopausal osteoporosis
Hui, S. L., Slemenda, C. W., & Johnston, C. C. (1990) · Osteoporosis International · doi:10.1007/bf01880413 · Cited by 417
Performance evaluation of a dual-energy X-ray bone densitometer
Mazess, R., Collick, B., Trempe, J., Barden, H., & Hanson, J. (1989) · Calcified Tissue International · doi:10.1007/bf02556569 · Cited by 352
Prediction of postmenopausal fracture risk with use of bone mineral measurements
Wasnich, R. D., Ross, P. D., Heilbrun, L. K., & Vogel, J. M. (1985) · American Journal of Obstetrics and Gynecology · doi:10.1016/0002-9378(85)90338-2 · Cited by 329
WAHNER, H. W., DUNN, W. L., BROWN, M. L., MORIN, R. L., & RIGGS, B. L. (1988) · Mayo Clinic Proceedings · doi:10.1016/s0025-6196(12)65502-5 · Cited by 229
Joseph^Melton, L., Kan, S. H., Wahner, H. W., & Lawrence Riggs, B. (1988) · Journal of Clinical Epidemiology · doi:10.1016/0895-4356(88)90036-4 · Cited by 229
Precision and stability of dual-energy X-ray absorptiometry measurements
Johnson, J., & Dawson-Hughes, B. (1991) · Calcified Tissue International · doi:10.1007/bf02556113 · Cited by 227
X-ray dual-photon absorptiometry: a new method for the measurement of bone density
Cullum, I. D., Ell, P. J., & Ryder, J. P. (1989) · The British Journal of Radiology · doi:10.1259/0007-1285-62-739-587 · Cited by 216
Quantitative Digital Radiography Versus Dual Photon Absorptiometry of the Lumbar Spine*
KELLY, T. L., SLOVIK, D. M., SCHOENFELD, D. A., & NEER, R. M. (1988) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jcem-67-4-839 · Cited by 214
Effective dose values in bone mineral measurements by photon absorptiometry and computed tomography
Kalender, W. A. (1992) · Osteoporosis International · doi:10.1007/bf01623841 · Cited by 210
Dual-energy radiographic absorptiometry for bone densitometry: current status and perspective
Sartoris, D., & Resnick, D. (1989) · American Journal of Roentgenology · doi:10.2214/ajr.152.2.241 · Cited by 163
Appropriate use of bone densitometry.
Genant, H. K., Block, J. E., Steiger, P., Glüer, C.-C., Ettinger, B. B., & Harris, S. T. (1989) · Radiology · doi:10.1148/radiology.170.3.2916037 · Cited by 145
Self-citationLang, P. K., Steiger, P., Faulkner, K. G., Glüer, C., & Genant, H. K. (1991) · Radiologic Clinics of North America · doi:10.1016/s0033-8389(22)02678-1 · Cited by 144
Self-citationAppendicular bone mineral and a woman's lifetime risk of hip fracture
Black, D. M., Cummings, S. R., & Melton, L. J. (1992) · Journal of Bone and Mineral Research · doi:10.1002/jbmr.5650070608 · Cited by 143
Enhanced precision with dual-energy x-ray absorptiometry
Mazess, R. B., Chesnut, C. H., McClung, M. R., & Genant, H. K. (1992) · Calcified Tissue International · doi:10.1007/bf00296209 · Cited by 139
Self-citationHansen, M. A., Hassager, C., Overgaard, K., Marslew, U., Riis, B. J., & Christiansen, C. (1990) · PubMed · Cited by 126
Osteoporosis. Current techniques and recent developments in quantitative bone densitometry.
Lang, P. K., Steiger, P., Faulkner, K. G., Glüer, C.-C., & Genant, H. K. (1991) · PubMed · Cited by 118
Self-citationRADIOLOGIC DIAGNOSIS OF OSTEOPOROSIS
Grampp, S., Jergas, M. D., Glüer, C., Lang, P. K., Brastow, P., & Genant, H. K. (1993) · Radiologic Clinics of North America · doi:10.1016/s0033-8389(22)00360-8 · Cited by 114
Self-citationFaulkner, K. G., Glüer, C.-C., Majumdar, S., Lang, P. K., Engelke, K., & Genant, H. K. (1991) · American Journal of Roentgenology · doi:10.2214/ajr.157.6.1950872 · Cited by 113
Self-citationPrecision and sensitivity of dual-energy X-ray absorptiometry in spinal osteoporosis
Pouillès, J. M., Trémollières, F., Todorovsky, N., & Ribot, C. A. (1991) · Journal of Bone and Mineral Research · doi:10.1002/jbmr.5650060914 · Cited by 112
Kalender, W. A. (1992) · Medical Physics · doi:10.1118/1.596899 · Cited by 106
Radiologic diagnosis of osteoporosis. Current methods and perspectives.
Grampp, S., Jergas, M. D., Glüer, C.-C., Lang, P. K., Brastow, P., & Genant, H. K. (1993) · PubMed · Cited by 105
Self-citationDuboeuf, F., Braillon, P. M., Chapuy, M. C., Haond, P., Hardouin, C., Mf, M., Delmas, P. D., & Meunier, P. J. (1991) · Osteoporosis International · doi:10.1007/bf03187468 · Cited by 104
In vivo and in vitro precision for bone density measured by dual-energy X-ray absorption
Lilley, J., Walters, B. G., Heath, D. A., & Drolc, Z. (1991) · Osteoporosis International · doi:10.1007/bf01625443 · Cited by 85
Cross-calibration of DXA equipment: Upgrading from a hologic QDR 1000/W to a QDR 2000
Faulkner, K. G., Gl�er, C., ESTILO, M. J., et al. (1993) · Calcified Tissue International · doi:10.1007/bf00308312 · Cited by 81
Self-citationMeasurement of bone mineral density: Current status
Genant, H. K., Faulkner, K. G., & Glüer, C. (1991) · The American Journal of Medicine · doi:10.1016/0002-9343(91)90248-v · Cited by 70
Self-citationCalibration of dual-energy X-ray absorptiometry for bone density
Mazess, R. B., Trempe, J., Bisek, J., Hanson, J. A., & Hans, D. B. (1991) · Journal of Bone and Mineral Research · doi:10.1002/jbmr.5650060804 · Cited by 59
Osteoporosis and Bone Density Measurement Methods
Ostlere, S., & Gold, R. H. (1991) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-199110000-00021 · Cited by 50
A comparison of two dual-energy X-ray absorptiometry systems for spinal bone mineral measurement
Lai, K., Goodsitt, M. M., Murano, R., & Chesnut, C. H. (1992) · Calcified Tissue International · doi:10.1007/bf00296283 · Cited by 49
Slosman, D. O., Rizzoli, R., Buchs, B., Piana, F., Donath, A., & Bonjour, J. ‐. (1990) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/bf00819396 · Cited by 42
Dual-energy x-ray bone densitometer incorporating an internal reference system
Stein, J., Lazewatsky, J. L., & Hochberg, A. (1987) · Cited by 35
Multicentre European COMAC-BME study on the standardisation of bone densitometry procedures
Dequeker, J., COMAC-BME Quantitative Assessment of Osteoporosis Study Group, REEVE, J., Pearson, J., Bright, J., Felsenberg, D., Kalender, W. A., Langton, C. M., Laval-Jeantet, A. M., Ruegsegger, P., et al. (1993) · Technology and Health Care · doi:10.3233/thc-1993-1202 · Cited by 29
Phantom studies in osteoporosis
Fischer, M. M., & Kempers, B. (1993) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/bf00209004 · Cited by 16
Nord, R. H. (1992) · Osteoporosis International · doi:10.1007/bf01623931 · Cited by 11
Cross-calibration of dual-energy X-ray absorptiometry (DXA) bone densitometry systems
Stetten, V. (1993) · Calcified Tissue International · Cited by 7
Cited by
Papaioannou, A., Morin, S., Cheung, A. M., Atkinson, S., Brown, J. P., Feldman, S., Hanley, D. A., Hodsman, A., Jamal, S. A., Kaiser, S. M., et al. (2010) · Canadian Medical Association Journal · doi:10.1503/cmaj.100771 · Cited by 1,749
Reginster, J.-Y., Minne, H. W., Sorensen, O. H., Hooper, M., Roux, C., Brandi, M. L., Lund, B., Ethgen, D., Pack, S., Roumagnac, I., et al. (2000) · Osteoporosis International · doi:10.1007/s001980050010 · Cited by 1,580
Prevalence of low femoral bone density in older U.S. women from NHANES III
Looker, A. C., Johnston, C. C., Wahner, H. W., Dunn, W. L., Calvo, M. S., Harris, T. B., Heyse, S. P., & Lindsay, R. L. (1995) · Journal of Bone and Mineral Research · doi:10.1002/jbmr.5650100517 · Cited by 1,379
Alendronate for the Treatment of Osteoporosis in Men
Orwoll, E., Ettinger, M., Weiss, S., Miller, P., Kendler, D., Graham, J., Adami, S., Weber, K., Lorenc, R., Pietschmann, P., et al. (2000) · New England Journal of Medicine · doi:10.1056/nejm200008313430902 · Cited by 973
Metadata
- Authors
- Genant, H. K., Grampp, S., Glüer, C. C., Faulkner, K. G., Jergas, M., Engelke, K., Hagiwara, S., & van Kuijk, C.
- Venue
- Journal of Bone and Mineral Research
- Publisher
- Oxford University Press (OUP)
- Published
- 1994-10-01
- Volume
- 9
- Issue
- 10
- Pages
- 1503-1514
- ISSN
- 0884-0431 (ISSN-L)
- 1523-4681
- OpenAlex
- W2115660903
- Cited by
- 610
- References
- 36
- FWCI
- 18.33
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.