Cryopreservation and long‐term liquid nitrogen storage of peripheral blood mononuclear cells for flow cytometry analysis effects on cell subset proportions and fluorescence intensity
The DOI matches its Crossref record.
Abstract
The effect of cryopreservation and longterm liquid nitrogen storage on peripheral blood mononuclear cell (PBMC) subsets was prospectively analyzed using monoclonal antibodies and flow cytometry. Brief cryopreservation did not significantly alter the proportion of positively stained cells for CD3+, CD4+, CD8+, CD14+, CD16+, and CD19+, cells. A small but statistically significant increase in the proportion of positive cells was observed for HLA‐DR+ and HLe‐1 + cells. Brief cryopreservation was associated with a decrease in the mean fluorescence intensity (MFl) values for CD3+, CD4+, and CD8+ cells; an increase in MFl values for CD14+ and HLA‐DR+ cells; and no change for CD16+, CD19+, and HLe‐1+ cells. There was no significant change in the proportion of CD3+, CD4+, or CD16+ cells during 20 months of storage in liquid nitrogen. Small but statistically significant decreases in the proportion of CD8+ and CD19+ cells were observed over the same interval, and the proportion of CD14+ cells (monocytes) was highly variable. Chronologic changes in fluorescence intensity during longterm storage were observed for all cell subsets except CD16+ and CD19+ cells. Cryopreservation is a valuable technique for longterm storage of viable cells. For many laboratory applications, the small changes noted in the present study will have no practical importance. However, for clinical and epidemiological investigations encompassing large numbers of samples, statistical techniques to adjust for small changes during storage should be considered.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Markers to measure immunomodulation in human nutrition intervention studies
Albers, R., Antoine, J.-M., Bourdet-Sicard, R., Calder, P. C., Gleeson, M., Lesourd, B., Samartín, S., Sanderson, I. R., Van Loo, J., Vas Dias, F. W., et al. (2005) · British Journal of Nutrition · doi:10.1079/bjn20051469 · Cited by 286
Corkum, C. P., Ings, D. P., Burgess, C., Karwowska, S., Kroll, W., & Michalak, T. I. (2015) · BMC Immunology · doi:10.1186/s12865-015-0113-0 · Cited by 186
Effects of cryopreservation on lymphocyte immunophenotype and function
Costantini, A., Mancini, S., Giuliodoro, S., Butini, L., Regnery, C. M., Silvestri, G., & Montroni, M. (2003) · Journal of Immunological Methods · doi:10.1016/s0022-1759(03)00202-3 · Cited by 185
TH1 and TH2 cell polarization increases with aging and is modulated by zinc supplementation
Uciechowski, P., Kahmann, L., Plümäkers, B., Malavolta, M., Mocchegiani, E., Dedoussis, G., Herbein, G., Jajte, J., Fulop, T., & Rink, L. (2008) · Experimental Gerontology · doi:10.1016/j.exger.2007.11.006 · Cited by 97
Metadata
- Authors
- Brown, L. M., Clark, J. W., Neuland, C. Y., Mann, D. L., Pankiw‐Trost, L. K., Blattner, W. A., & Tollerud, D. J.
- Venue
- Journal of Clinical Laboratory Analysis
- Publisher
- Wiley
- Published
- 1991-01
- Volume
- 5
- Issue
- 4
- Pages
- 255-261
- ISSN
- 0887-8013 (ISSN-L)
- 1098-2825
- OpenAlex
- W2090728337
- Cited by
- 48
- References
- 0
- FWCI
- 0.00
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.