Association between exposure to nonactionable physiologic monitor alarms and response time in a children's hospital
Open accessThe DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Alarm fatigue is reported to be a major threat to patient safety, yet little empirical data support its existence in the hospital. OBJECTIVE: To determine if nurses exposed to high rates of nonactionable physiologic monitor alarms respond more slowly to subsequent alarms that could represent life‐threatening conditions. DESIGN: Observational study using video. SETTING: Freestanding children's hospital. PATIENTS: Pediatric intensive care unit (PICU) patients requiring inotropic support and/or mechanical ventilation, and medical ward patients. INTERVENTION: None. MEASUREMENTS: Actionable alarms were defined as correctly identifying physiologic status and warranting clinical intervention or consultation. We measured response time to alarms occurring while there were no clinicians in the patient's room. We evaluated the association between the number of nonactionable alarms the patient had in the preceding 120 minutes (categorized as 0–29, 30–79, or 80+ alarms) and response time to subsequent alarms in the same patient using a log‐rank test that accounts for within‐nurse clustering. RESULTS: We observed 36 nurses for 210 hours with 5070 alarms; 87.1% of PICU and 99.0% of ward clinical alarms were nonactionable. Kaplan‐Meier plots showed incremental increases in response time as the number of nonactionable alarms in the preceding 120 minutes increased (log‐rank test stratified by nurse P < 0.001 in PICU, P = 0.009 in the ward). CONCLUSIONS: Most alarms were nonactionable, and response time increased as nonactionable alarm exposure increased. Alarm fatigue could explain these findings. Future studies should evaluate the simultaneous influence of workload and other factors that can impact response time. Journal of Hospital Medicine 2015;10:345–351. © 2015 Society of Hospital Medicine
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Harris, P. A., Taylor, R., Thielke, R., Payne, J., Gonzalez, N., & Conde, J. G. (2009) · Journal of Biomedical Informatics · doi:10.1016/j.jbi.2008.08.010 · Cited by 51,384
Parsons, H. M. (1974) · Science · doi:10.1126/science.183.4128.922 · Cited by 615
Sendelbach, S., & Funk, M. (2013) · AACN Advanced Critical Care · doi:10.4037/nci.0b013e3182a903f9 · Cited by 497
Lawless (1994) · doi:10.1097/00003246-199406000-00017 · Cited by 406
Chambrin, M.-C., Ravaux, P., Calvelo-Aros, D., Jaborska, A., Chopin, C., & Boniface, B. (1999) · Intensive Care Medicine · doi:10.1007/s001340051082 · Cited by 227 · cited 1×
“However, monitors generate frequent alarms, and most are not relevant to the patient’s safety (over 90% of pediatric intensive care unit (PICU)(1,2) and over 70% of adult intensive care alarms).(5,6) In psychology experiments, humans rapidly learn to ignore or respond more slowly to alarms when exposed to high false-a…”
Background
Cited by
Sandau, K. E., Funk, M., Auerbach, A., Barsness, G. W., Blum, K., Cvach, M., Lampert, R., May, J. L., McDaniel, G. M., Perez, M. V., et al. (2017) · Circulation · doi:10.1161/cir.0000000000000527 · Cited by 342
Alarm fatigue: impacts on patient safety
Ruskin, K. J., & Hueske-Kraus, D. (2015) · Current Opinion in Anaesthesiology · doi:10.1097/aco.0000000000000260 · Cited by 226
“situation requiring clinical intervention is addressed [16].”
BackgroundPaine, C. W., Goel, V. V., Ely, E., Stave, C. D., Stemler, S., Zander, M., & Bonafide, C. P. (2016) · Journal of Hospital Medicine · doi:10.1002/jhm.2520 · Cited by 183
“Relationship Between Alarm Exposure and Response Time Whereas 9 studies addressed response time, only 2 evaluated the relationship between alarm burden and nurse response time.(20,22) Voepel-Lewis and colleagues found that nurse responses were slower to patients with the highest quartile of alarms (57.”
BackgroundMethodInfluentialSelf-citationWinters, B. D., Cvach, M. M., Bonafide, C. P., Hu, X., Konkani, A., O’Connor, M. F., Rothschild, J. M., Selby, N. M., Pelter, M. M., McLean, B., et al. (2018) · Critical Care Medicine · doi:10.1097/ccm.0000000000002803 · Cited by 170
Self-citationChaparro, J. D., Beus, J. M., Dziorny, A. C., Hagedorn, P. A., Hernandez, S., Kandaswamy, S., Kirkendall, E. S., McCoy, A. B., Muthu, N., & Orenstein, E. W. (2022) · Applied Clinical Informatics · doi:10.1055/s-0042-1748856 · Cited by 76
Metadata
- Authors
- Bonafide, C. P., Lin, R., Zander, M., Graham, C. S., Paine, C. W., Rock, W., Rich, A., Roberts, K. E., Fortino, M., Nadkarni, V. M., Localio, A. R., & Keren, R.
- Venue
- Journal of Hospital Medicine
- Publisher
- Wiley
- Published
- 2015-04-15
- Volume
- 10
- Issue
- 6
- Pages
- 345-351
- ISSN
- 1553-5592 (ISSN-L)
- 1553-5606
- OpenAlex
- W1920471355
- Cited by
- 180
- References
- 5
- FWCI
- 16.97
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.