Alarm fatigue: impacts on patient safety
Abstract
PURPOSE OF REVIEW: Electronic medical devices are an integral part of patient care. As new devices are introduced, the number of alarms to which a healthcare professional may be exposed may be as high as 1000 alarms per shift. The US Food and Drug Administration has reported over 500 alarm-related patient deaths in five years. The Joint Commission, recognizing the clinical significance of alarm fatigue, has made clinical alarm management a National Patient Safety Goal. RECENT FINDINGS: Potential solutions to alarm fatigue include technical, organizational, and educational interventions. Selecting only the right monitors (i.e., avoiding overmonitoring), judicious selection of alarm limits, and multimodal alarms can all reduce the number of nuisance alarms to which a healthcare worker is exposed. SUMMARY: Alarm fatigue can jeopardize safety, but some clinical solutions such as setting appropriate thresholds and avoiding overmonitoring are available.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
False alarms desensitize clinical staff to critical alarms (alarm fatigue) and pose a major patient safety issue, leading to alarm-related patient deaths every year.
“False alarms desensitize clinical staff to critical alarms (ie, alarm fatigue) and pose a major patient safety issue, leading to alarm-related patient deaths every year [29].”
From Clinical requirements of future patient monitoring in the intensive care unit: qualitative study (2019) · cites this paper as [29]
Several strategies have been developed to reduce false alarms in the ICU, but implementation into clinical routine is still lacking.
“Although several strategies have been developed to reduce false alarms in the ICU [12,28-31], implementation into a clinical routine is still lacking.”
From Clinical requirements of future patient monitoring in the intensive care unit: qualitative study (2019) · cites this paper as [29]
Cites
Association of Interruptions With an Increased Risk and Severity of Medication Administration Errors
Westbrook, J. I. (2010) · Archives of Internal Medicine · doi:10.1001/archinternmed.2010.65 · Cited by 772 · see citing works
Monitor Alarm Fatigue : An Integrative Review
Cvach, M. M. (2012) · Biomedical Instrumentation & Technology · doi:10.2345/0899-8205-46.4.268 · Cited by 641 · see citing works
Monitor Alarm Fatigue: Standardizing Use of Physiological Monitors and Decreasing Nuisance Alarms
Graham, K. C., & Cvach, M. M. (2010) · American Journal of Critical Care · doi:10.4037/ajcc2010651 · Cited by 460 · see citing works
Drew, B. J., Harris, P., Zègre-Hemsey, J. K., Mammone, T., Schindler, D., Salas-Boni, R., Bai, Y., Tinoco, A., Ding, Q., & Hu, X. (2014) · PLoS ONE · doi:10.1371/journal.pone.0110274 · Cited by 438 · see citing works
The impact of interruptions on clinical task completion
Westbrook, J. I., Coiera, E. W., Dunsmuir, W. T. M., Brown, B. M., Kelk, N. J., Paoloni, R., & Tran, C. (2010) · BMJ Quality & Safety · doi:10.1136/qshc.2009.039255 · Cited by 344 · see citing works
Rompaey, B. V., Elseviers, M. M., Drom, W. V., Fromont, V., & Jorens, P. G. (2012) · Critical Care · doi:10.1186/cc11330 · Cited by 297 · see citing works
Li, S. Y. W., Magrabi, F., & Coiera, E. W. (2011) · Journal of the American Medical Informatics Association · doi:10.1136/amiajnl-2010-000024 · Cited by 214 · see citing works
Improving Alarm Performance in the Medical Intensive Care Unit Using Delays and Clinical Context
Görges, M., Markewitz, B. A., & Westenskow, D. R. (2009) · Anesthesia & Analgesia · doi:10.1213/ane.0b013e31819bdfbb · Cited by 212 · see citing works
Bonafide, C. P., Lin, R., Zander, M. I., Graham, C. S., Paine, C. W., Rock, W. L., Rich, A., Roberts, K. E., Fortino, M., Nadkarni, V., et al. (2015) · Journal of Hospital Medicine · doi:10.1002/jhm.2331 · Cited by 182 · see citing works
Borowski, M., Görges, M., Fried, R., Such, O., Wrede, C. E., & Imhoff, M. (2011) · Biomedizinische Technik/Biomedical Engineering · doi:10.1515/bmt.2011.005 · Cited by 114 · see citing works
Overlapping Melodic Alarms Are Almost Indiscriminable
Lacherez, P. F., Seah, E. L., & Sanderson, P. M. (2007) · Human Factors The Journal of the Human Factors and Ergonomics Society · doi:10.1518/001872007x215719 · Cited by 82 · see citing works
Analysis of the soundscape in an intensive care unit based on the annotation of an audio recording
Park, M., Kohlrausch, A., de Bruijn, W., et al. (2014) · The Journal of the Acoustical Society of America · doi:10.1121/1.4868367 · Cited by 62 · see citing works
Mondor, T. A., & Finley, G. A. (2003) · Canadian Journal of Anesthesia/Journal canadien d anesthésie · doi:10.1007/bf03017788 · Cited by 57 · see citing works
Christensen, M., Dodds, A., Sauer, J., & Watts, N. (2014) · Intensive and Critical Care Nursing · doi:10.1016/j.iccn.2014.02.003 · Cited by 54 · see citing works
Funk, M., Winkler, C. G., May, J. L., Stephens, K., Fennie, K., Rose, L., Turkman, Y., & Drew, B. J. (2010) · Journal of Electrocardiology · doi:10.1016/j.jelectrocard.2010.07.018 · Cited by 49 · see citing works
Tams, S., Thatcher, J. B., Grover, V., & Pak, R. (2015) · Anxiety Stress & Coping · doi:10.1080/10615806.2015.1011141 · Cited by 43 · see citing works
Effect of Altering Alarm Settings: A Randomized Controlled Study
Cvach, M. M., Rothwell, K. J., Cullen, A. M., Nayden, M. G., Cvach, N., & Pham, J. C. (2015) · Biomedical Instrumentation & Technology · doi:10.2345/0899-8205-49.3.214 · Cited by 40 · see citing works
Edworthy, J. R., Page, R., Hibbard, A., et al. (2013) · Applied Ergonomics · doi:10.1016/j.apergo.2013.10.003 · Cited by 37 · see citing works
Tanaka, P. P., Tanaka, M., & Drover, D. R. (2014) · Journal of Clinical Monitoring and Computing · doi:10.1007/s10877-014-9556-8 · Cited by 22 · see citing works
Workplace Blame and Related Concepts
Davidson, J. E., Agan, D. L., Chakedis, S., & Skrobik, Y. K. (2015) · CHEST Journal · doi:10.1378/chest.15-0332 · Cited by 19 · see citing works
Rothman, B. S., Dexter, F., & Epstein, R. H. (2013) · Anesthesia & Analgesia · doi:10.1213/ane.0b013e318299a7f7 · Cited by 15 · see citing works
Bailey, J. M. (2015) · Ergonomics · doi:10.1080/00140139.2015.1021861 · Cited by 13 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
Lambert, S. I., Madi, M., Sopka, S., Lenes, A., Stange, H., Buszello, C.-P., & Stephan, A. (2023) · npj Digital Medicine · doi:10.1038/s41746-023-00852-5 · Cited by 404 · see citing works
Clinical requirements of future patient monitoring in the intensive care unit: qualitative study
Poncette, A.-S., Spies, C., Mosch, L., Schieler, M., Weber-Carstens, S., Krampe, H., & Balzer, F. (2019) · JMIR Medical Informatics · doi:10.2196/13064 · Cited by 136 · see citing works
Get To The Point! Problem-Based Curated Data Views To Augment Care For Critically Ill Patients
Zhang, M., Ehrmann, D., Mazwi, M., Eytan, D., Ghassemi, M., & Chevalier, F. (2022) · CHI Conference on Human Factors in Computing Systems · doi:10.1145/3491102.3501887 · Cited by 16 · see citing works
Chappel, E. (2023) · Global Journal of Engineering and Technology Advances · doi:10.30574/gjeta.2023.16.3.0181 · Cited by 1 · see citing works
- Authors
- Ruskin, K. J., & Hueske-Kraus, D.
- Affiliations
- University of Chicago (US)
- Corresponding author
- Ruskin, Keith J.
- ORCID
- Ruskin, Keith J.
- Venue
- Current Opinion in Anaesthesiology
- Published
- 2015-12
- Volume
- 28
- Issue
- 6
- Pages
- 685-690
- ISSN
- 0952-7907 (ISSN-L)
- OpenAlex
- W2416677955
- Cited by
- 226
- References
- 22
- Citations by year
- 2026: 20 · 2025: 23 · 2024: 34 · 2023: 36 · 2022: 20 · 2021: 21 · 2020: 27 · 2019: 17 · 2018: 11 · 2017: 10 · 2016: 7
- FWCI
- 9.41
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Current Opinion in Anaesthesiology (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Surgery › Healthcare Technology and Patient Monitoring
- Health Sciences › Health Professions › Emergency Medical Services › Patient Safety and Medication Errors
- Health Sciences › Health Professions › Health Information Management › Electronic Health Records Systems
- Keywords
- alarm fatigue, clinical alarm systems, electronic medical devices, patient safety, alarm management, alarm thresholds, National Patient Safety Goals
- MeSH terms
- Fatigue, Humans, Monitoring, Physiologic, Noise, United States, Clinical Alarms, Patient Safety
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review