The DOI matches its Crossref record; 2,974 of the 2,974 references it cites were found in a registry or an index.
Survey of the year 2003 commercial optical biosensor literature
Abstract
In the year 2003 there was a 17% increase in the number of publications citing work performed using optical biosensor technology compared with the previous year. We collated the 962 total papers for 2003, identified the geographical regions where the work was performed, highlighted the instrument types on which it was carried out, and segregated the papers by biological system. In this overview, we spotlight 13 papers that should be on everyone's 'must read' list for 2003 and provide examples of how to identify and interpret high-quality biosensor data. Although we still find that the literature is replete with poorly performed experiments, over-interpreted results and a general lack of understanding of data analysis, we are optimistic that these shortcomings will be addressed as biosensor technology continues to mature.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
3 retracted
Baglia, F. A., Badellino, K. O., Li, C. Q., López, J. A., & Walsh, P. N. (2002) · Journal of Biological Chemistry · doi:10.1074/jbc.m108319200 · Cited by 109
RetractedSaini, A. K., Maithal, K., Chand, P., Chowdhury, S., Vohra, R., Goyal, A., Dubey, G. P., Chopra, P., Chandra, R., Tyagi, A. K., et al. (2004) · Journal of Biological Chemistry · doi:10.1074/jbc.m409944200 · Cited by 32
RetractedFluorobodies combine GFP fluorescence with the binding characteristics of antibodies
Zeytun, A., Jeromin, A., Scalettar, B. A., Waldo, G. S., & Bradbury, A. M. (2003) · Nature Biotechnology · doi:10.1038/nbt911 · Cited by 31
RetractedIn Vivo Activation of the p53 Pathway by Small-Molecule Antagonists of MDM2
Vassilev, L. T., Vu, B. T., Graves, B., Carvajal, D., Podlaski, F., Filipovic, Z., Kong, N., Kammlott, U., Lukacs, C., Klein, C., et al. (2004) · Science · doi:10.1126/science.1092472 · Cited by 4,661
Selective recognition of methylated lysine 9 on histone H3 by the HP1 chromo domain
Bannister, A. J., Zegerman, P., Partridge, J. F., Miska, E. A., Thomas, J. O., Allshire, R. C., & Kouzarides, T. (2001) · Nature · doi:10.1038/35065138 · Cited by 2,903
Present and future of surface plasmon resonance biosensors
Homola, J. (2003) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-003-2101-0 · Cited by 2,321
Lipocalin 2 mediates an innate immune response to bacterial infection by sequestrating iron
Flo, T. H., Smith, K. D., Sato, S., Rodriguez, D. J., Holmes, M. A., Strong, R. K., Akira, S., & Aderem, A. (2004) · Nature · doi:10.1038/nature03104 · Cited by 1,877
A Survey of Structure−Property Relationships of Surfaces that Resist the Adsorption of Protein
Ostuni, E., Chapman, R. G., Holmlin, R. E., Takayama, S., & Whitesides, G. M. (2001) · Langmuir · doi:10.1021/la010384m · Cited by 1,799
Identification of the haemoglobin scavenger receptor
Kristiansen, M., Graversen, J. H., Jacobsen, C., Sonne, O., Hoffman, H.-J., Law, S. K. A., & Moestrup, S. K. (2001) · Nature · doi:10.1038/35051594 · Cited by 1,712
Fiber-Optic Chemical Sensors and Biosensors
Wolfbeis, O. S. (2006) · Analytical Chemistry · doi:10.1021/ac060490z · Cited by 1,627
Cited by
Surface Plasmon Resonance Sensors for Detection of Chemical and Biological Species
Homola, J. (2008) · Chemical Reviews · doi:10.1021/cr068107d · Cited by 4,525
Small-molecule inhibitors of protein–protein interactions: progressing towards the dream
Arkin, M. R., & Wells, J. A. (2004) · Nature Reviews Drug Discovery · doi:10.1038/nrd1343 · Cited by 1,705
Plasmonic Surface Lattice Resonances: A Review of Properties and Applications
Kravets, V. G., Kabashin, A. V., Barnes, W. L., & Grigorenko, A. N. (2018) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00243 · Cited by 1,501
Long-range surface plasmon polaritons
Berini, P. (2009) · Advances in Optics and Photonics · doi:10.1364/aop.1.000484 · Cited by 996
Making it stick: convection, reaction and diffusion in surface-based biosensors
Squires, T. M., Messinger, R. J., & Manalis, S. R. (2008) · Nature Biotechnology · doi:10.1038/nbt1388 · Cited by 986
The Density and Refractive Index of Adsorbing Protein Layers
Vörös, J. (2004) · Biophysical Journal · doi:10.1529/biophysj.103.030072 · Cited by 752
SHANKARAN, D., GOBI, K., & MIURA, N. (2007) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2006.09.014 · Cited by 607
Chemical Strategies for Generating Protein Biochips
Jonkheijm, P., Weinrich, D., Schröder, H., Niemeyer, C. M., & Waldmann, H. (2008) · Angewandte Chemie International Edition · doi:10.1002/anie.200801711 · Cited by 590
Folding-Based Electrochemical Biosensors: The Case for Responsive Nucleic Acid Architectures
Lubin, A. A., & Plaxco, K. W. (2010) · Accounts of Chemical Research · doi:10.1021/ar900165x · Cited by 506
Cooper, M. A., & Singleton, V. T. (2007) · Journal of Molecular Recognition · doi:10.1002/jmr.826 · Cited by 370
Label-free optical biosensors for food and biological sensor applications
Khansili, N., Rattu, G., & Krishna, P. M. (2018) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2018.03.004 · Cited by 328
The Human IL-17F/IL-17A Heterodimeric Cytokine Signals through the IL-17RA/IL-17RC Receptor Complex
Wright, J. F., Bennett, F., Li, B., Brooks, J., Luxenberg, D. P., Whitters, M. J., Tomkinson, K. N., Fitz, L. J., Wolfman, N. M., Collins, M., et al. (2008) · The Journal of Immunology · doi:10.4049/jimmunol.181.4.2799 · Cited by 316
Nanoparticle labels in immunosensing using optical detection methods
Seydack, M. (2005) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2004.11.003 · Cited by 314
Aykul, S., & Martinez-Hackert, E. (2016) · Analytical Biochemistry · doi:10.1016/j.ab.2016.06.025 · Cited by 284
Optofluidics for energy applications
Erickson, D., Sinton, D., & Psaltis, D. (2011) · Nature Photonics · doi:10.1038/nphoton.2011.209 · Cited by 277
Multiplexed DNA Quantification by Spectroscopic Shift of Two Microsphere Cavities
Vollmer, F., Arnold, S., Braun, D., Teraoka, I., & Libchaber, A. (2003) · Biophysical Journal · doi:10.1016/s0006-3495(03)74625-6 · Cited by 276
Higher-throughput, label-free, real-time molecular interaction analysis
Rich, R. L., & Myszka, D. G. (2007) · Analytical Biochemistry · doi:10.1016/j.ab.2006.10.040 · Cited by 264
Self-citationTerahertz Spectroscopic Analysis of Peptides and Proteins
Falconer, R. J., & Markelz, A. G. (2012) · Journal of Infrared, Millimeter, and Terahertz Waves · doi:10.1007/s10762-012-9915-9 · Cited by 181
(2018) · doi:10.1080/19420862.2017.1389355 · Cited by 80
Aponte, V. M., Finch, D. S., & Klaus, D. M. (2006) · Life Sciences · doi:10.1016/j.lfs.2006.04.007 · Cited by 51
DIP/Dpr interactions and the evolutionary design of specificity in protein families
Sergeeva, A. P., Katsamba, P. S., Cosmanescu, F., Brewer, J. J., Ahlsen, G., Mannepalli, S., Shapiro, L., & Honig, B. (2020) · Nature Communications · doi:10.1038/s41467-020-15981-8 · Cited by 38
Metadata
- Authors
- Rich, R. L., & Myszka, D. G.
- Venue
- Journal of Molecular Recognition
- Publisher
- Wiley
- Published
- 2005-01
- Volume
- 18
- Issue
- 1
- Pages
- 1-39
- ISSN
- 0952-3499 (ISSN-L)
- 1099-1352
- OpenAlex
- W2158062848
- Cited by
- 505
- References
- 2,974
- FWCI
- 12.79
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.