The DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.
Neurostimulation systems for deep brain stimulation: In vitro evaluation of magnetic resonance imaging–related heating at 1.5 tesla
Open accessAbstract
Purpose: To assess magnetic resonance imaging (MRI)‐related heating for a neurostimulation system (Activa® Tremor Control System, Medtronic, Minneapolis, MN) used for chronic deep brain stimulation (DBS). Materials and Methods: Different configurations were evaluated for bilateral neurostimulators (Soletra® Model 7426), extensions, and leads to assess worst‐case and clinically relevant positioning scenarios. In vitro testing was performed using a 1.5‐T/64‐MHz MR system and a gel‐filled phantom designed to approximate the head and upper torso of a human subject. MRI was conducted using the transmit/receive body and transmit/receive head radio frequency (RF) coils. Various levels of RF energy were applied with the transmit/receive body (whole‐body averaged specific absorption rate (SAR); range, 0.98–3.90 W/kg) and transmit/receive head (whole‐body averaged SAR; range, 0.07–0.24 W/kg) coils. A fluoroptic thermometry system was used to record temperatures at multiple locations before (1 minute) and during (15 minutes) MRI. Results: Using the body RF coil, the highest temperature changes ranged from 2.5°–25.3° C. Using the head RF coil, the highest temperature changes ranged from 2.3°–7.1° C.Thus, these findings indicated that substantial heating occurs under certain conditions, while others produce relatively minor, physiologically inconsequential temperature increases. Conclusion: The temperature increases were dependent on the type of RF coil, level of SAR used, and how the lead wires were positioned. Notably, the use of clinically relevant positioning techniques for the neurostimulation system and low SARs commonly used for imaging the brain generated little heating. Based on this information, MR safety guidelines are provided. These observations are restricted to the tested neurostimulation system. J. Magn. Reson. Imaging 2002;15:241–250. © 2002 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Radiofrequency Energy-Induced Heating During MR Procedures: A Review
Shellock, F. G. (2000) · Journal of Magnetic Resonance Imaging · Cited by 343
Self-citationOn the heating of linear conductive structures as guide wires and catheters in interventional MRI
Nitz, W. R., Oppelt, A., Renz, W., Manke, C., Lenhart, M., & Link, J. (2001) · Journal of Magnetic Resonance Imaging · doi:10.1002/1522-2586(200101)13:1<105::aid-jmri1016>3.0.co;2-0 · Cited by 321
Temperature regulation in mammals and other vertebrates
Bligh, J. (1973) · Medical Entomology and Zoology · Cited by 286
TEMPERATURE REGULATION IN MAMMALS AND OTHER VERTEBRATES
Spalding, J. M. K. (1974) · Journal of Neurology, Neurosurgery & Psychiatry · doi:10.1136/jnnp.37.3.362-c · Cited by 262
Effects of magnetic resonance imaging on cardiac pacemakers and electrodes
Achenbach, S. S., Moshage, W. E. L., Diem, B., Bieberlea, T., Schibgilla, V., & Bachmann, K. F. (1997) · American Heart Journal · doi:10.1016/s0002-8703(97)70083-8 · Cited by 254
Houdas, Y., & Ring, E. F. J. (1982) · Springer eBooks · doi:10.1007/978-1-4899-0345-7 · Cited by 199
Rezai, A. R., Lozano, A. M., Crawley, A. P., Joy, M. L. G., Davis, K. D., Kwan, C. L., Dostrovsky, J. O., Tasker, R. R., & Mikulis, D. J. (1999) · Journal of Neurosurgery · doi:10.3171/jns.1999.90.3.0583 · Cited by 169
Self-citationSafe Performance of Magnetic Resonance Imaging on Five Patients with Permanent Cardiac Pacemakers
Gimbel, J., JOHNSON, D., LEVINE, P. A., & Wilkoff, B. L. (1996) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.1996.tb03387.x · Cited by 145
Magnetic Resonance Imaging with Implanted Neurostimulators: An In Vitro and In Vivo Study
Tronnier, V. M., Staubert, A., Hähnel, S., & Sarem-Aslani, A. (1999) · Neurosurgery · doi:10.1097/00006123-199901000-00073 · Cited by 125
Chronic thalamic stimulation with three-dimensional MR stereotactic guidance.
Dormont, D., Cornu, P., Pidoux, B., Bonnet, A. M., Biondi, A., Oppenheim, C., Hasboun, D., Damier, P., Cuchet, E., Philippon, J. H., et al. (1997) · PubMed · Cited by 86
Cited by
MR Procedures: Biologic Effects, Safety, and Patient Care
Shellock, F. G., & Crues, J. V. (2004) · Radiology · doi:10.1148/radiol.2323030830 · Cited by 563
Self-citationMagnetic resonance imaging and cardiac pacemaker safety at 1.5-Tesla
Martin, E. T., Coman, J. A., Shellock, F. G., Pulling, C. C., Fair, R., & Jenkins, K. (2004) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2003.12.016 · Cited by 422
Self-citationHenderson, J. M., Tkach, J., Phillips, M., Baker, K., Shellock, F. G., & Rezai, A. R. (2005) · Neurosurgery · doi:10.1227/01.neu.0000180810.16964.3e · Cited by 314
Self-citationRezai, A. R., Phillips, M., Baker, K. B., Sharan, A. D., Nyenhuis, J., Tkach, J., Henderson, J., & Shellock, F. G. (2004) · Investigative Radiology · doi:10.1097/01.rli.0000124940.02340.ab · Cited by 192
“However, to date, the absolute safety of using MR systems operating at other field strengths (ie, both more than and less than 1.5 T), with other transmit RF coils, has not been established for neurostimulation systems used for DBS.”
BackgroundInfluentialSelf-citation
Metadata
- Authors
- Rezai, A. R., Finelli, D., Nyenhuis, J. A., Hrdlicka, G., Tkach, J., Sharan, A., Rugieri, P., Stypulkowski, P. H., & Shellock, F. G.
- Venue
- Journal of Magnetic Resonance Imaging
- Publisher
- Wiley
- Published
- 2002-02-28
- Volume
- 15
- Issue
- 3
- Pages
- 241-250
- ISSN
- 1053-1807 (ISSN-L)
- 1522-2586
- OpenAlex
- W2011515258
- Cited by
- 285
- References
- 15
- FWCI
- 14.67
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.