Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 285

The DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.

Neurostimulation systems for deep brain stimulation: In vitro evaluation of magnetic resonance imaging–related heating at 1.5 tesla

Open access
Rezai, Ali R., Finelli, Daniel, Nyenhuis, John A., Hrdlicka, Greg, Tkach, Jean, Sharan, Ashwini, Rugieri, Paul, Stypulkowski, Paul H., Shellock, Frank G. · 2002 · Journal of Magnetic Resonance Imaging

Abstract

Purpose: To assess magnetic resonance imaging (MRI)‐related heating for a neurostimulation system (Activa® Tremor Control System, Medtronic, Minneapolis, MN) used for chronic deep brain stimulation (DBS). Materials and Methods: Different configurations were evaluated for bilateral neurostimulators (Soletra® Model 7426), extensions, and leads to assess worst‐case and clinically relevant positioning scenarios. In vitro testing was performed using a 1.5‐T/64‐MHz MR system and a gel‐filled phantom designed to approximate the head and upper torso of a human subject. MRI was conducted using the transmit/receive body and transmit/receive head radio frequency (RF) coils. Various levels of RF energy were applied with the transmit/receive body (whole‐body averaged specific absorption rate (SAR); range, 0.98–3.90 W/kg) and transmit/receive head (whole‐body averaged SAR; range, 0.07–0.24 W/kg) coils. A fluoroptic thermometry system was used to record temperatures at multiple locations before (1 minute) and during (15 minutes) MRI. Results: Using the body RF coil, the highest temperature changes ranged from 2.5°–25.3° C. Using the head RF coil, the highest temperature changes ranged from 2.3°–7.1° C.Thus, these findings indicated that substantial heating occurs under certain conditions, while others produce relatively minor, physiologically inconsequential temperature increases. Conclusion: The temperature increases were dependent on the type of RF coil, level of SAR used, and how the lead wires were positioned. Notably, the use of clinically relevant positioning techniques for the neurostimulation system and low SARs commonly used for imaging the brain generated little heating. Based on this information, MR safety guidelines are provided. These observations are restricted to the tested neurostimulation system. J. Magn. Reson. Imaging 2002;15:241–250. © 2002 Wiley‐Liss, Inc.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/jmri.10069

Cites

15 of 15 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 285

Metadata

Authors
Rezai, A. R., Finelli, D., Nyenhuis, J. A., Hrdlicka, G., Tkach, J., Sharan, A., Rugieri, P., Stypulkowski, P. H., & Shellock, F. G.
Venue
Journal of Magnetic Resonance Imaging
Publisher
Wiley
Published
2002-02-28
Volume
15
Issue
3
Pages
241-250
ISSN
  • 1053-1807 (ISSN-L)
  • 1522-2586
OpenAlex
W2011515258
Cited by
285
References
15
FWCI
14.67
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.