TrueFISP: Assessment of accuracy for measurement of left ventricular mass in an animal model

Fieno, David S., Jaffe, Wyatt C., Simonetti, Orlando P., Judd, Robert M., Finn, J. Paul · 2002 · Journal of Magnetic Resonance Imaging
Cited by 91

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Abstract

Purpose: To test the accuracy of a high performance true fast imaging with steady‐state precession (TrueFISP) pulse sequence for the assessment of left ventricular (LV) mass in a large animal model on 1.5‐T scanners. Materials and Methods: We imaged dogs (N = 10) on a clinical 1.5‐T clinical scanner using electrocardiogram (ECG)‐gated TrueFISP. In all animals, contiguous segmented k‐space cine images were acquired from base to apex (in‐plane resolution 1 × 1 mm 2, slice thickness 5 mm, TR = 4.8 msec, TE = 1.6 msec) during repeated breath‐holds. In nine of the 10 animals, single‐shot images gated to end‐diastole were also acquired from base to apex in a single breath‐hold (in‐plane resolution 1 × 1 mm 2, slice thickness 5 mm, TR = 3.2 msec, TE = 1.6 msec). After imaging, animals were killed, the left ventricle was isolated, and the true mass of the left ventricle (free wall and septum) was determined. Independently, two observers blinded to the post‐mortem results computed LV masses based on analysis of the magnetic resonance (MR) images. Results: Comparison of the computed LV mass using TrueFISP to the actual mass showed excellent agreement. Cine‐systole was the most accurate technique (mass = 98.6% ± 4.5% actual, bias = 1.2 ± 3.4 g) followed by cine‐diastole (mass = 97.9% ± 5.3% actual, bias = 1.8 ± 4.1 g) and single shot (mass = 94.7% ± 7.9% actual, bias = 4.2 ± 6.3 g). Inter‐ and intra‐observer variabilities were low (5.8% ± 7.1% and 0.4% ± 4.8%, respectively). Conclusion: We conclude that TrueFISP imaging is an accurate, rapid method to determine ventricular mass. In single‐shot mode, TrueFISP requires only one breath‐hold to estimate the mass of the heart within 6% of the actual value, whereas the segmented k‐space implementation measured LV mass to within 3% of the true value. J. Magn. Reson. Imaging 2002;15:526–531. © 2002 Wiley‐Liss, Inc.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/jmri.10107

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

See all 91

Metadata

Authors
Fieno, D. S., Jaffe, W. C., Simonetti, O. P., Judd, R. M., & Finn, J. P.
Venue
Journal of Magnetic Resonance Imaging
Publisher
Wiley
Published
2002-04-26
Volume
15
Issue
5
Pages
526-531
ISSN
  • 1053-1807 (ISSN-L)
  • 1522-2586
OpenAlex
W2081548030
Cited by
91
References
4
FWCI
6.64
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: TrueFISP: Assessment of accuracy for measurement of left ventricular mass in an animal model. https://app.cochat.ai/papers/10.1002/jmri.10107
The paper
Fieno, D. S., Jaffe, W. C., Simonetti, O. P., Judd, R. M., & Finn, J. P. (2002). TrueFISP: Assessment of accuracy for measurement of left ventricular mass in an animal model. Journal of Magnetic Resonance Imaging. https://doi.org/10.1002/jmri.10107

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.