Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 328

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Insights into the use of paramagnetic Gd(III) complexes in MR‐molecular imaging investigations

Open access
Aime, Silvio, Cabella, Claudia, Colombatto, Sebastiano, Geninatti Crich, Simonetta, Gianolio, Eliana, Maggioni, Fabio·2002·Journal of Magnetic Resonance Imaging

Abstract

Can gadolinium III [Gd(III)] complexes be considered good candidates for magnetic resonance (MR)‐molecular imaging studies? In this review article, we examine the principal issues that are the basis of successful use of Gd‐based protocols in molecular imaging applications. High relaxivity is the primary requisite. Therefore, the design of such paramagnetic probes has to be pursued keeping in mind the relationships between structure, dynamics, and the relevant parameters involved in paramagnetic relaxation processes. Moreover, the limited number of target molecules on cellular membranes makes it necessary to define strategies aimed at delivering many Gd‐containing moieties to the sites of interest. Examples are reported for the attainment of very high relaxivities for the design of new routes for pursuing the accumulation of small sized Gd(III) complexes at the targeting sites. An efficient cellular uptake of Gd‐containing probes is the key step for attaining the visualization of targeted cells by MR imaging, and selected examples are reported. In this context, the problem of the assessment of the minimum amount of Gd(III) complexes necessary for the MR imaging‐visualization of cells has been addressed by reporting the authors' observations on the cell‐internalization of Gd(III) complexes. A particularly efficient delivery system is represented by Gd‐loaded apoferritin, which allows the MR visualization of hepatocytes when the number of Gd‐complexes per cell is 4 ± 1 × 10 7. Finally, the potential of responsive systems is considered by outlining the exploitation of the amplification effect brought about by the action of a specific enzymatic activity on the relaxivity of a suitably functionalized Gd(III) complex. J. Magn. Reson. Imaging 2002;16:394–406. © 2002 Wiley‐Liss, Inc.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/jmri.10180

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 328

Metadata

Authors
Aime, S., Cabella, C., Colombatto, S., Geninatti Crich, S., Gianolio, E., & Maggioni, F.
Venue
Journal of Magnetic Resonance Imaging
Publisher
Wiley
Published
2002-09-25
Volume
16
Issue
4
Pages
394-406
ISSN
  • 1053-1807 (ISSN-L)
  • 1522-2586
OpenAlex
W1989436965
Cited by
328
References
1
FWCI
11.46
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Insights into the use of paramagnetic Gd(III) complexes in MR‐molecular imaging investigations. https://app.cochat.ai/papers/10.1002/jmri.10180
The paper
Aime, S., Cabella, C., Colombatto, S., Geninatti Crich, S., Gianolio, E., & Maggioni, F. (2002). Insights into the use of paramagnetic Gd(III) complexes in MR‐molecular imaging investigations. Journal of Magnetic Resonance Imaging. https://doi.org/10.1002/jmri.10180

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.