The DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.
Insights into the use of paramagnetic Gd(III) complexes in MR‐molecular imaging investigations
Open accessAbstract
Can gadolinium III [Gd(III)] complexes be considered good candidates for magnetic resonance (MR)‐molecular imaging studies? In this review article, we examine the principal issues that are the basis of successful use of Gd‐based protocols in molecular imaging applications. High relaxivity is the primary requisite. Therefore, the design of such paramagnetic probes has to be pursued keeping in mind the relationships between structure, dynamics, and the relevant parameters involved in paramagnetic relaxation processes. Moreover, the limited number of target molecules on cellular membranes makes it necessary to define strategies aimed at delivering many Gd‐containing moieties to the sites of interest. Examples are reported for the attainment of very high relaxivities for the design of new routes for pursuing the accumulation of small sized Gd(III) complexes at the targeting sites. An efficient cellular uptake of Gd‐containing probes is the key step for attaining the visualization of targeted cells by MR imaging, and selected examples are reported. In this context, the problem of the assessment of the minimum amount of Gd(III) complexes necessary for the MR imaging‐visualization of cells has been addressed by reporting the authors' observations on the cell‐internalization of Gd(III) complexes. A particularly efficient delivery system is represented by Gd‐loaded apoferritin, which allows the MR visualization of hepatocytes when the number of Gd‐complexes per cell is 4 ± 1 × 10 7. Finally, the potential of responsive systems is considered by outlining the exploitation of the amplification effect brought about by the action of a specific enzymatic activity on the relaxivity of a suitably functionalized Gd(III) complex. J. Magn. Reson. Imaging 2002;16:394–406. © 2002 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The nature of .pi.-.pi. interactions
Hunter, C. A., & Sanders, J. K. M. (1990) · Journal of the American Chemical Society · doi:10.1021/ja00170a016 · Cited by 5,353
Gadolinium(III) Chelates as MRI Contrast Agents: Structure, Dynamics, and Applications
Caravan, P., Ellison, J. J., McMurry, T. J., & Lauffer, R. B. (1999) · Chemical Reviews · doi:10.1021/cr980440x · Cited by 4,483
The ferritins: molecular properties, iron storage function and cellular regulation
Harrison, P. M., & Arosio, P. (1996) · Biochimica et Biophysica Acta (BBA) - Bioenergetics · doi:10.1016/0005-2728(96)00022-9 · Cited by 2,667
The Chemistry of Contrast Agents in Medical Magnetic Resonance Imaging
(2013) · Wiley eBooks · doi:10.1002/9781118503652 · Cited by 1,468
Weissleder, R., & Mahmood, U. (2001) · Radiology · doi:10.1148/radiology.219.2.r01ma19316 · Cited by 1,315
Detection of tumor angiogenesis in vivo by αvβ3-targeted magnetic resonance imaging
Sipkins, D. A., Cheresh, D. A., Kazemi, M. R., Nevin, L. M., Bednarski, M. D., & Li, K. C. P. (1998) · Nature Medicine · doi:10.1038/nm0598-623 · Cited by 850
Dendrimer‐based metal chelates: A new class of magnetic resonance imaging contrast agents
Wiener, E., Brechbiel, M. W., Brothers, H., Magin, R. L., Gansow, O. A., Tomalia, D. A., & Lauterbur, P. C. (1994) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910310102 · Cited by 718
Lanthanide( III ) chelates for NMR biomedical applications
Aime, S., Botta, M., Fasano, M., & Terreno, E. (1998) · Chemical Society Reviews · doi:10.1039/a827019z · Cited by 710
Self-citationMagnetically labeled cells can be detected by MR imaging
Weissleder, R., Cheng, H., Bogdanova, A., & Bogdanov, A. (1997) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880070140 · Cited by 336
A “Smart” Magnetic Resonance Imaging Agent That Reports on Specific Enzymatic Activity
Moats, R. A., Fraser, S. E., & Meade, T. J. (1997) · Angewandte Chemie International Edition in English · doi:10.1002/anie.199707261 · Cited by 330
Cited by
Controlled drug delivery vehicles for cancer treatment and their performance
Senapati, S., Mahanta, A. K., Kumar, S., & Maiti, P. (2018) · Signal Transduction and Targeted Therapy · doi:10.1038/s41392-017-0004-3 · Cited by 2,167
Lee, H., Lee, E., Kim, D. K., Jang, N. K., Jeong, Y. Y., & Jon, S. (2006) · Journal of the American Chemical Society · doi:10.1021/ja061529k · Cited by 594
Classification and basic properties of contrast agents for magnetic resonance imaging
Geraldes, C. F. G. C., & Laurent, S. (2009) · Contrast Media & Molecular Imaging · doi:10.1002/cmmi.265 · Cited by 541
Gadolinium(iii) complexes as MRI contrast agents: ligand design and properties of the complexes
Hermann, P., Kotek, J., Kubíček, V., & Lukeš, I. (2008) · Dalton Transactions · doi:10.1039/b719704g · Cited by 530
Chemical exchange saturation transfer imaging and spectroscopy
Zhou, J., & Zijl, P. C. M. V. (2006) · Progress in Nuclear Magnetic Resonance Spectroscopy · doi:10.1016/j.pnmrs.2006.01.001 · Cited by 485
New approaches for imaging tumour responses to treatment
Brindle, K. (2008) · Nature Reviews Cancer · doi:10.1038/nrc2289 · Cited by 460
Gd(III)-BASED CONTRAST AGENTS FOR MRI
AIME, S., BOTTA, M., & TERRENO, E. (2005) · Advances in Inorganic Chemistry · doi:10.1016/s0898-8838(05)57004-1 · Cited by 345
Self-citationMolecular imaging for cancer diagnosis and surgery
Hussain, T., & Nguyen, Q. T. (2014) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2013.09.007 · Cited by 337
In vivo molecular and genomic imaging: new challenges for imaging physics
Cherry, S. R. (2004) · Physics in Medicine and Biology · doi:10.1088/0031-9155/49/3/r01 · Cited by 334
Next Generation, High Relaxivity Gadolinium MRI Agents
Raymond, K. N., & Pierre, V. C. (2005) · Bioconjugate Chemistry · doi:10.1021/bc049817y · Cited by 328
Modo, M., Hoehn, M., & Bulte, J. W. M. (2005) · Molecular Imaging · doi:10.1162/15353500200505145 · Cited by 294
How to determine free Gd and free ligand in solution of Gd chelates. A technical note
Barge, A., Cravotto, G., Gianolio, E., & Fedeli, F. (2006) · Contrast Media & Molecular Imaging · doi:10.1002/cmmi.110 · Cited by 291
Self-citationIn vivo magnetic resonance imaging of acute brain inflammation using microparticles of iron oxide
McAteer, M. A., Sibson, N. R., von zur Muhlen, C., Schneider, J. E., Lowe, A. S., Warrick, N., Channon, K. M., Anthony, D. C., & Choudhury, R. P. (2007) · Nature Medicine · doi:10.1038/nm1631 · Cited by 289
Viral nanoparticles as platforms for next-generation therapeutics and imaging devices
Steinmetz, N. F. (2010) · Nanomedicine: Nanotechnology, Biology and Medicine · doi:10.1016/j.nano.2010.04.005 · Cited by 259
Hu, F., Jia, Q., Li, Y., & Gao, M. (2011) · Nanotechnology · doi:10.1088/0957-4484/22/24/245604 · Cited by 147
Metadata
- Authors
- Aime, S., Cabella, C., Colombatto, S., Geninatti Crich, S., Gianolio, E., & Maggioni, F.
- Venue
- Journal of Magnetic Resonance Imaging
- Publisher
- Wiley
- Published
- 2002-09-25
- Volume
- 16
- Issue
- 4
- Pages
- 394-406
- ISSN
- 1053-1807 (ISSN-L)
- 1522-2586
- OpenAlex
- W1989436965
- Cited by
- 328
- References
- 24
- FWCI
- 11.46
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.