The DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.
Insights into the use of paramagnetic Gd(III) complexes in MR‐molecular imaging investigations
Open accessAbstract
Can gadolinium III [Gd(III)] complexes be considered good candidates for magnetic resonance (MR)‐molecular imaging studies? In this review article, we examine the principal issues that are the basis of successful use of Gd‐based protocols in molecular imaging applications. High relaxivity is the primary requisite. Therefore, the design of such paramagnetic probes has to be pursued keeping in mind the relationships between structure, dynamics, and the relevant parameters involved in paramagnetic relaxation processes. Moreover, the limited number of target molecules on cellular membranes makes it necessary to define strategies aimed at delivering many Gd‐containing moieties to the sites of interest. Examples are reported for the attainment of very high relaxivities for the design of new routes for pursuing the accumulation of small sized Gd(III) complexes at the targeting sites. An efficient cellular uptake of Gd‐containing probes is the key step for attaining the visualization of targeted cells by MR imaging, and selected examples are reported. In this context, the problem of the assessment of the minimum amount of Gd(III) complexes necessary for the MR imaging‐visualization of cells has been addressed by reporting the authors' observations on the cell‐internalization of Gd(III) complexes. A particularly efficient delivery system is represented by Gd‐loaded apoferritin, which allows the MR visualization of hepatocytes when the number of Gd‐complexes per cell is 4 ± 1 × 10 7. Finally, the potential of responsive systems is considered by outlining the exploitation of the amplification effect brought about by the action of a specific enzymatic activity on the relaxivity of a suitably functionalized Gd(III) complex. J. Magn. Reson. Imaging 2002;16:394–406. © 2002 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The nature of .pi.-.pi. interactions
Hunter, C. A., & Sanders, J. K. M. (1990) · Journal of the American Chemical Society · doi:10.1021/ja00170a016 · Cited by 5,353
Gadolinium(III) Chelates as MRI Contrast Agents: Structure, Dynamics, and Applications
Caravan, P., Ellison, J. J., McMurry, T. J., & Lauffer, R. B. (1999) · Chemical Reviews · doi:10.1021/cr980440x · Cited by 4,483
The ferritins: molecular properties, iron storage function and cellular regulation
Harrison, P. M., & Arosio, P. (1996) · Biochimica et Biophysica Acta (BBA) - Bioenergetics · doi:10.1016/0005-2728(96)00022-9 · Cited by 2,667
The Chemistry of Contrast Agents in Medical Magnetic Resonance Imaging
(2013) · Wiley eBooks · doi:10.1002/9781118503652 · Cited by 1,468
Weissleder, R., & Mahmood, U. (2001) · Radiology · doi:10.1148/radiology.219.2.r01ma19316 · Cited by 1,315
Detection of tumor angiogenesis in vivo by αvβ3-targeted magnetic resonance imaging
Sipkins, D. A., Cheresh, D. A., Kazemi, M. R., Nevin, L. M., Bednarski, M. D., & Li, K. C. P. (1998) · Nature Medicine · doi:10.1038/nm0598-623 · Cited by 850
Dendrimer‐based metal chelates: A new class of magnetic resonance imaging contrast agents
Wiener, E., Brechbiel, M. W., Brothers, H., Magin, R. L., Gansow, O. A., Tomalia, D. A., & Lauterbur, P. C. (1994) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910310102 · Cited by 718
Lanthanide( III ) chelates for NMR biomedical applications
Aime, S., Botta, M., Fasano, M., & Terreno, E. (1998) · Chemical Society Reviews · doi:10.1039/a827019z · Cited by 710
Self-citationMagnetically labeled cells can be detected by MR imaging
Weissleder, R., Cheng, H., Bogdanova, A., & Bogdanov, A. (1997) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880070140 · Cited by 336
A “Smart” Magnetic Resonance Imaging Agent That Reports on Specific Enzymatic Activity
Moats, R. A., Fraser, S. E., & Meade, T. J. (1997) · Angewandte Chemie International Edition in English · doi:10.1002/anie.199707261 · Cited by 330
Aime, S., Frullano, L., & Geninatti Crich, S. (2002) · Angewandte Chemie International Edition · doi:10.1002/1521-3773(20020315)41:6<1017::aid-anie1017>3.0.co;2-p · Cited by 302
Self-citationA Novel pH‐Sensitive MRI Contrast Agent
Zhang, S., Wu, K., & Sherry, A. D. (1999) · Angewandte Chemie International Edition · Cited by 259
Targeting Dendrimer-Chelates to Tumors and Tumor Cells Expressing the High-Affinity Folate Receptor
WIENER, E. C., KONDA, S., SHADRON, A., BRECHBIEL, M., & GANSOW, O. (1997) · INVESTIGATIVE RADIOLOGY · doi:10.1097/00004424-199712000-00005 · Cited by 214
Bhorade, R., Weissleder, R., Nakakoshi, T., Moore, A., & Tung, C.-H. (2000) · Bioconjugate Chemistry · doi:10.1021/bc990168d · Cited by 163
The Cellular Labile Iron Pool and Intracellular Ferritin in K562 Cells
Konijn, A. M., Glickstein, H., Vaisman, B. L., Meyron‐Holtz, E. G., Slotki, I. N., & Cabantchik, Z. I. (1999) · Blood · doi:10.1182/blood.v94.6.2128 · Cited by 156
Relaxivity of Gadolinium(III) Complexes: Theory and Mechanism
Tóth, É., Helm, L., & Merbach, A. E. (2013) · Wiley eBooks · doi:10.1002/9781118503652.ch2 · Cited by 152
Bogdanov, A. A., Jr., Matuszewski, L., Bremer, C., et al. (2002) · Molecular Imaging · doi:10.1162/153535002753395671 · Cited by 139
Kabalka, G. W., Davis, M. A. F., Moss, T. H., Buonocore, E., Hübner, K. F., Holmberg, E. G., Maruyama, K., & Huang, L. (1991) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910190231 · Cited by 111
Fargion, S., Fracanzani, A. L., Brando, B., Arosio, P., Levi, S., & Fiorelli, G. (1991) · Blood · doi:10.1182/blood.v78.4.1056.1056 · Cited by 78
Ferritin iron kinetics and protein turnover in K562 cells.
Roberts, S., & Bomford, A. B. (1988) · Journal of Biological Chemistry · doi:10.1016/s0021-9258(18)37407-6 · Cited by 68
Molecular Entrapment of Small Molecules within the Interior of Horse Spleen Ferritin
Webb, B., Frame, J., Zhao, Z., Lee, M. L., & Watt, G. D. (1994) · Archives of Biochemistry and Biophysics · doi:10.1006/abbi.1994.1100 · Cited by 64
Characteristics and expression of binding sites specific for ferritin H- chain on human cell lines
Fargion, S. R., Arosio, P., Fracanzani, A. L., Cislaghi, V., Levi, S., Cozzi, A., Piperno, A., & Fiorelli, G. (1988) · Blood · doi:10.1182/blood.v71.3.753.753 · Cited by 64
Pathways in the binding and uptake of ferritin by hepatocytes
Osterloh, K. R. S., & Aisen, P. (1989) · Biochimica et Biophysica Acta (BBA) - Molecular Cell Research · doi:10.1016/0167-4889(89)90075-x · Cited by 50
Bligh, S. W. A., Harding, C. T., Sadler, P. J., Bulman, R. A., Bydder, G. M., Pennock, J. M., Kelly, J. D., Clatham, I. A., & Marriott, J. A. (1991) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910170222 · Cited by 39
Cited by
Controlled drug delivery vehicles for cancer treatment and their performance
Senapati, S., Mahanta, A. K., Kumar, S., & Maiti, P. (2018) · Signal Transduction and Targeted Therapy · doi:10.1038/s41392-017-0004-3 · Cited by 2,167
Lee, H., Lee, E., Kim, D. K., Jang, N. K., Jeong, Y. Y., & Jon, S. (2006) · Journal of the American Chemical Society · doi:10.1021/ja061529k · Cited by 594
Classification and basic properties of contrast agents for magnetic resonance imaging
Geraldes, C. F. G. C., & Laurent, S. (2009) · Contrast Media & Molecular Imaging · doi:10.1002/cmmi.265 · Cited by 541
Gadolinium(iii) complexes as MRI contrast agents: ligand design and properties of the complexes
Hermann, P., Kotek, J., Kubíček, V., & Lukeš, I. (2008) · Dalton Transactions · doi:10.1039/b719704g · Cited by 530
Chemical exchange saturation transfer imaging and spectroscopy
Zhou, J., & Zijl, P. C. M. V. (2006) · Progress in Nuclear Magnetic Resonance Spectroscopy · doi:10.1016/j.pnmrs.2006.01.001 · Cited by 485
Metadata
- Authors
- Aime, S., Cabella, C., Colombatto, S., Geninatti Crich, S., Gianolio, E., & Maggioni, F.
- Venue
- Journal of Magnetic Resonance Imaging
- Publisher
- Wiley
- Published
- 2002-09-25
- Volume
- 16
- Issue
- 4
- Pages
- 394-406
- ISSN
- 1053-1807 (ISSN-L)
- 1522-2586
- OpenAlex
- W1989436965
- Cited by
- 328
- References
- 24
- FWCI
- 11.46
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.