Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 171

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

High field human imaging

Norris, David G.·2003·Journal of Magnetic Resonance Imaging

Abstract

This review article examines the state of knowledge regarding human imaging using MRI at high main magnetic field strengths. The article starts with a summary of the technical issues associated with magnetic field strengths in the range of 3–8 T, including magnet characteristics and the properties of radiofrequency magnetic fields, with special reference to sensitivity, power deposition, and homogeneity. The published data on tissue‐water relaxation times in the brain is tabulated and the implications for contrast and pulse sequence implementation is elucidated. The behavior of the major fast imaging sequences, fast low angle shot (FLASH), rapid acquisition with relaxation enhancement (RARE), and echo planar imaging (EPI), is examined in this context. A number of anatomical images from 3 T systems are presented as examples. Particular attention is given to various forms of vascular imaging, namely, time of flight angiography, venography, and arterial spin labeling. The most complex changes in contrast with main magnetic field strength are in activation studies utilizing the blood oxygen level dependent mechanism, which are examined in detail. Improvements in spatial specificity are emphasized, particularly in conjunction with spin‐echo imaging. The article concludes with a discussion of the current status and the potential impact of technical developments such as parallel imaging. J. Magn. Reson. Imaging 2003;18:519–529. © 2003 Wiley‐Liss, Inc.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/jmri.10390

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 171

Metadata

Authors
Norris, D. G.
Venue
Journal of Magnetic Resonance Imaging
Publisher
Wiley
Published
2003-10-20
Volume
18
Issue
5
Pages
519-529
ISSN
  • 1053-1807 (ISSN-L)
  • 1522-2586
OpenAlex
W2132583101
Cited by
171
References
3
FWCI
12.67
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: High field human imaging. https://app.cochat.ai/papers/10.1002/jmri.10390
The paper
Norris, D. G. (2003). High field human imaging. Journal of Magnetic Resonance Imaging. https://doi.org/10.1002/jmri.10390

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.