The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
“Keyhole” method for accelerating imaging of contrast agent uptake
Abstract
Magnetic resonance (MR) imaging methods with good spatial and contrast resolution are often too slow to follow the uptake of contrast agents with the desired temporal resolution. Imaging can be accelerated by skipping the acquisition of data normally taken with strong phase‐encoding gradients, restricting acquisition to weak‐gradient data only. If the usual procedure of substituting zeros for the missing data is followed, blurring results. Substituting instead reference data taken before or well after contrast agent injection reduces this problem. Volunteer and patient images obtained by using such reference data show that imaging can be usefully accelerated severalfold. Cortical and medullary regions of interest and whole kidney regions were studied, and both gradientand spin‐echo images are shown. The method is believed to be compatible with other acceleration methods such as half‐Fourier reconstruction and reading of more than one line of k space per excitation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Functional mapping of the human visual cortex by magnetic resonance imaging
Belliveau, J. W., Kennedy, D. N., McKinstry, R. C., Buchbinder, B. R., Weisskoff, R. M., Cohen, M. S., Vevea, J. M., Brady, T. J., & Rosen, B. R. (1991) · Science · doi:10.1126/science.1948051 · Cited by 1,883
Cited by
Feng, L., Grimm, R., Block, K. T., Chandarana, H., Kim, S., Xu, J., Axel, L., Sodickson, D. K., & Otazo, R. (2014) · Magnetic Resonance in Medicine · doi:10.1002/mrm.24980 · Cited by 718
Parallel magnetic resonance imaging
Larkman, D. J., & Nunes, R. G. (2007) · Physics in Medicine and Biology · doi:10.1088/0031-9155/52/7/r01 · Cited by 327
FMRI activations of amygdala, cingulate cortex, and auditory cortex by infant laughing and crying
Sander, K., Frome, Y., & Scheich, H. (2007) · Human Brain Mapping · doi:10.1002/hbm.20333 · Cited by 121
Left Auditory Cortex and Amygdala, but Right Insula Dominance for Human Laughing and Crying
Sander, K., & Scheich, H. (2005) · Journal of Cognitive Neuroscience · doi:10.1162/089892905774597227 · Cited by 93
Metadata
- Authors
- Van Vaals, J. J., Brummer, M. E., Thomas Dixon, W., Tuithof, H. H., Engels, H., Nelson, R. C., Gerety, B. M., Chezmar, J. L., & Den Boer, J. A.
- Venue
- Journal of Magnetic Resonance Imaging
- Publisher
- Wiley
- Published
- 1993-07
- Volume
- 3
- Issue
- 4
- Pages
- 671-675
- ISSN
- 1053-1807 (ISSN-L)
- 1522-2586
- OpenAlex
- W2115186446
- Cited by
- 602
- References
- 1
- FWCI
- 10.22
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: “Keyhole” method for accelerating imaging of contrast agent uptake. https://app.cochat.ai/papers/10.1002/jmri.1880030419
- The paper
- Van Vaals, J. J., Brummer, M. E., Thomas Dixon, W., Tuithof, H. H., Engels, H., Nelson, R. C., Gerety, B. M., Chezmar, J. L., & Den Boer, J. A. (1993). “Keyhole” method for accelerating imaging of contrast agent uptake. Journal of Magnetic Resonance Imaging. https://doi.org/10.1002/jmri.1880030419
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.